Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted rate | |
| 2 | L2₹37.5 L+₹55,663.50 (1.50%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-AOC Not accepted since higher quoted rate | |
| 3 | L3₹38.1 L+₹1.1 L (3.08%)Rejected-AOC | L3 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
Refer Docs
EMD Value
₹67,000
Closing Date
2 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS
PROVN OF SEPTIC TANK WITH SOAKAGE PIT TWO SANITARY BLOCK WITH ALLIED FACILITIES TOILET AND TWO INCINERATOR AT MIL STN DHRANGADHRA
2020_MES_360177_2
GE(A)/GNR/TOKEN/43 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹67,000
Yes
18 Sept 2020
20 Aug 2020
4 Sept 2020
20 Aug 2020
2 Sept 2020
21 Aug 2020
60 days
Amount
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavation over areas not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation over areas not exceeding 1.5m in depth and getting out in hard rock complete all as specified and directed.
Excavation over areas exceeding 1.5m in depth but not exceeding 3m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation over areas exceeding 1.5m in depth but not exceeding 3m in depth and getting out in hard rock complete all as specified and directed.
Excavation over areas exceeding 3m in depth but not exceeding 4.5m in depth and getting out in hard rock complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole, laying of cables etc in soft/loose soil and getting out.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth, for foundation, etc in hard/dense soil and getting out.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation or for shaft, wells, cesspits, manholes, piers holes etc not exc 10 sqm on plan and getting out in soft/disinegrated rock all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for manholes, septic tanks, wells etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceedng 1.5m in deptch but not exceeding 3m in depth for foundation etc or for manholes, septic tanks, wells etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in soft/loose soil complete all as specified and directed.
M&L for Tibba sand for sand cushioning to under ground cable including, spreading, leveling hand punning complete all as specified and directed.
Supplying and laying jodhpur stone patti for cable protection of lenth between 55 to 60 cm but width between 25 to 30 cm thicknes not less than 5 cm complete all specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soft/disintegrated rock completed as specified and directed.
Removing excavated material (soil), not exceeding 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
Removing of excavated material exc 250m but n.exc 500m and depositing where directed at a ;eve; mpt exceedomg 1/5 mtr above the starting point complete all as specified and directed.
M&L for loose filling with broken bricks in soakage pits, soakage wells complete all as specified and directed.
M&L for hard core of gauge not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, spread, levelled and rammed to a true surface including watering complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1, using 20 mm graded stone aggregate as in surface channels and drains, benching, haunching etc. complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2, using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L for cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate in coping and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
M&L pre-cast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in kitchen platform, shelves , cover and simillar articles including placing the cover in position and set in cement mortar (1:4) complete all as specified and directed. Note: Reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete (nominal mix) type B-1, 1:2:4 (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4 , type B-1 using 20mm graded stone aggregate in chajjas complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4 , type B-1 using 20mm graded stone aggregate in beams, cantilevers, bressumers, lintels over 1:5m span complete all as specified and directed.
M&L for reinforced cement concrete, M-30 (design mix) using 20mm graded stone aggregate as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs and mass cocrete complete all as specified and directed.
M&L for reinforced cement concreted, M-30 (design mix) using 20mm graded agregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L for RCC M-25 ( Design Mix ) ( using 20mm graded stone aggregate ) as in suspended slabs supported on walls/columns, in floors, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC M-30 ( Design Mix ) ( using 20mm graded stone aggregate ) as in suspended slabs supported on walls/columns, in floors, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 25-30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
Supply only, integral water proofing compound.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and directed.
M&L for firebrick work in linings to fire places, flues, etc. (other than in chimney shafts), set, jointed and pointed in fireclay complete all as specified and directed.
M&L for walling of random rubble stone masonry, uncoarsed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for walling of random rubble stone masonry, uncoarsed brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto course with maximum depression on face from straight edge held against the dressed surface not.exc. 20mm for sand stone complete all as specified and directed.
M&L for flat fair finished surfaces formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc vertical or to batter complete all as specified and directed.
M&L for form work to soffit of suspended slabs such as roof slabs, floor slabs, landings and simillar works not exceeding 20cm thick and rough finished surfaces of concrete all as specified and directed.
S&F 35 mm thick, 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F, 30mm thick flush shutters, solid core construction, with block board core and plywood face panles, commercial type on both sides complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specifications complete all as specified and directed.
S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed
S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
S&F, butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed.
S&F, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars etc and similar work conforming to Fe-290 (Gde-E-165) including applying one shop coat of red oxide primer complete all as specified and directed
S&F, 250mm dia, flue pipes of mild steel sheet, black, in suitable lengths as approved by the E.I.C. fixed to walls complete all as specified and directed.
S&F, Cowls (with 3 stays), riveted to and including 15 cm length of flue pipes of 250mm dia complete all as specified and directed.
S&F, Roof plates with sleeve pieces riveted or welded thereto, and similar roof and ceiling connections complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bend to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for MS rolled sections (Fe 410-W (Gde-E-250) quality-A) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
M&L for rolled mild steel angle iron work as in door frames complete, drilled for fixing of hinges etc. also fastening and fixing conforming to Fe-290 (Gde-E-165) complete all as specified and directed.
S&F, factory made steel windows with side hung shutter including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded including applying one shop coat of red oxide primer complete all as specified and directed.
S&F, factory made steel windows with side hung shutter including box type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded including applying one shop coat of red oxide primer complete all as specified and directed.
S&F, factory made steel ventilators with top hung shutter including hinges, steel peg stay, glazing bars including applying one shop coat of red oxide primer all as specified and directed
S&F, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F, false ceiling, at any height, 600 x 600mm grid with Armstrong 'Prelude XL 32' grid system and 16mm thick mineral fibre acoustic tile 'RH - 99 Classic lite' with suspension system complete all as specified and per manufacturer's instruction. Make : Armstrong or equivalent as approved by GE.
M&L for 100mm thick cement concrete (1;2:4), type B-2 (using 40mm graded stone aggregate) as in hard standing, laid in alternate bays and finished surfaces even and smooth using extra cement complete all as specified and directed .
M&L for 50mm thick cement concrete 1:3:6 type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/hard standing and finishing the surface even and fair without using extra cement complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 300 x 200 x 7mm thick on vertical surfaces such as skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match over and including rendering 10mm thick in cement mortar (1:4) complete all as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L for rendering 20mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair faces of brick work is to be finishedeven and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on block/stone masonry surfaces using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, finished even and smooth without using extra cement complete all as specified and directed. Note:- Supply only water proofing compound shall be measured and paid separately.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of white cmement putty complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc. 0.5sq.m in each pane complete all as specified and directed.
M&L for 3mm thick figured glass, pin headed type and glazing with oil putty in square not exc. 0.5sq.m in each pane complete all as specified and directed.
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over existing shop coat of primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
S&F, 32mm bore, low density polyethelene pipe (HDPE) of pressure rating 6kgf/sq.cm fixed to walls, ceilings or in floors etc. complete all as specified and directed.
S&F, 40mm dia High density poythelyne (HDPE) pipes of pressure rating 6kgf/sqm fixed to wall ceiling or laid in floors etc complete all as specified and directed
Supply, hoisting, fixing in position and connecting,500 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top), ISI marked, including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size and 20mm dia PTMT ball valve all as specified in SSR Part-I complete all as specified and directed.
Supply, hoisting, fixing in position and connecting, 1000 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top), ISI marked, including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
S&F, bib taps, cast copper alloy, fancy type, chromium plated, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S&F, pillar taps cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S&F, pillar taps cast copper alloy with capstan head, fancy type chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S&F, stop valves, fancy type, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
S&F, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, waste coupling of PTMT (half or full threaded) minimum weight 45gms of 32mm bore of discharge pipe suitable for urinals complete all as specified and directed.
Supply & Fix, PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F, 100mm bore cast iron soil waste or vent pipes (sand cast) in any length with or without ears with cement joints fixed to walls etc all as specified and directed .
S&F, 100mm bore cast iron vent cowls complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius, with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius, with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) branch piece, single(Single Y) equal or unequal with access door complete all as specified and directed.
S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR), vent cowl complete all as specified and directed.
S&F, PVC (SWR) floor trap, with chromium plated grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed.
S&F, PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 150mm bore of pipe complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 200mm bore of pipe complete all as specified and directed.
M&L for salt glazed stone ware drain pipes, 150mm internal diameter, grade 'A' laid in trenches and jointed complete all as specified and directed.
S&F for 200mm bore reinforced concrete pipe class NP3, laid and jointed complete with collars all as specified and directed.
Cutting into existing manholes for connecting new drain pipes, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cment concrete (1:2:4) type B1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 150mm bore of pipe complete all as specified and directed.
S&F, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed.
S&F, vitreous china squattinbg pan, 'Orissa' pattern of size 580mm x 440mm with integral foot rest (excluding flushing cistern and flush pipe) including joining, filling and provision of cement concrete bedding 1:5:10, type E2, using 20mm graded aggregate complete all as specified and directed.
S&F, vitreous china wash down water closet pan (pedestal pattern), with seat cover (including fixing bolts but excluding flushing cistern and flush pipe) with seat and cover complete all as specified and directed.
S&F, vitreous china squatting pan, 'Orissa’ pattern, white of size 580mm x 440mm with integral foot rest, P or S trap (excluding flushing cistern and flush pipe) including plain cement concrete (1:5:10) type D-2 using 40 mm graded stone aggregate as in filling in sunken portion etc. complete all as specified and directed.
S&F, vitreous china bowl urinal flat back, of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing flush pipe grating and union for discharge pipe with urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed. Note :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately.
S&F, 10 litres capacity, PVC low level, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and connection to pipe or lever etc. complete all as specified and directed.
S&F, 10 litres capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and connection to pipe or lever etc. complete all as specified and directed.
S&F, 32mm dia High density poythelyne (HDPE) pipes of pressure rating 6kgf/sqm as in waste pipe for urinal, sink, etc
S&F, brass chromium plated shower rose with or without swivel joint, 125mm size complete all as specified and directed.
S&F, Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as speficied and directed
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for One light/fan point controlled by one switch.
S&F, lamp holder/angle holder, insulate body with back plate suitable for batten fittings complete all as specified and directed
(d) One multi pin 5 Amps, socket outlet on Independent board.
M&L for wiring with and including multistranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F box type fitting 1 x 18W, blue coloured end caps, prewired for LED tube including LED tube 18 watts, including connecting up with twin core twisted copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make Crompton Greaves cat Part No. for Fitting DMLN1LT8 and for tube light LTT8-16 or equivalent make as approved by GE.
S&F, 1x6 watts, LED bulk head luminaires deep drawn anodised body, epoxy white powder coated, heat resistant , prisamatic glass cover with specially designed gasket, including LED 6 Watt, and connecting up with twin core twisted flexible copper cable of suitable size and testing on completion all as specified and directed. As per Cat No. BIBWP6WLED of Make:- Bajaj or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, LED building security light fitting 1x12W with polycarbonate housing, Aluminium gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sqmm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS, FI clamp including plinth with nut bolts etc. complete all as specified and directed. Make : Crompton Greaves Cat Part No. LSTN-12-CDL or equivalent make of Havells/Philips.
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, sheet metal distribution board, SPN, 4 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable all as specified and directed of sizes 10 Sqmm, 2 core of cables.
S&F, miniature circuit breakers, SPN, 40 Amps, 240 volts, fixed in sheet metal board complete all as specified and directed.
S&F, miniature circuit breakers, SP, 6 to 32 Amps complete all as specified and directed. Make - Havells/Legrand or equivalent make as specified under Appx 'C'.
S&F, Exhaust Fan, 200mm Sweep, single phase, 230/240 volts, including making opening for exhaust fan including grouting nut, bolts and washer for fixing of fan and making good the disturbed surfaces all as per existing and mounting fan including connected with suitable three core copper conductor cable complete all as specified and directed. As per Cat No. FHVVEDXOWH08 enti Air of Havells or equivalent make as approved by GE from the make specified in Appx 'C'.
S&F, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC concealed conduit and conduit acessories including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 2.5 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: (i) 2 runs of main conductor, one run of earth conductor and one run of PVC conduit and acessories shall be measured as one unit length.(ii) Rate quoted shall deemed to includes cuttings chases for consealing PVC conduit and making good the disturbed surfaces in CM 1:3 complete.
M&L,earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
ALBA AC AND REF SERVICES
AMI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .