| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 1ST FLOOR SCO 3 SECTOR 41 U T CHANDIGARH | NA | NA | 160001 | L1 | Accepted-AOC work awarded to M/s Hipath Technologies being L1 firm | |
| 2 | L2₹10.4 L+₹43,865 (4.39%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 firm | |
| 3 | Rejected-Technical | - | Rejected-Technical BID RESPONSIVE BUT DISQUALIFIED | |
| 4 | Rejected-Technical | - | Rejected-Technical BID RESPONSIVE BUT DISQUALIFIED |
Tender Value
₹9.7 L
EMD Value
₹19,500
Closing Date
19 Jul 2022, 10:00 amClosed
Executive Engineer, Electrical Division, HP.PWD Ma
Executive Engineer, Electrical Division, HP.PWD Mandi
Special repair and reinstallation testing and commissioning of Fire alarm system installed at Shri lal bahadur Shastri Government Medical college and Hospital Nerchowk Distt Mandi HP
2022_PWD_62515_1
PW/MED/TA/NIT/ e-notice/22-23-2425-35 dt 30.06.22
Open Tender
Electrical Works
Item Rate
180 days
NERCHOWK
PLEASE REFER TO BID DOC
11 documents required · 11 mandatory
₹350
₹19,500
Yes
23 Nov 2022
12 Jul 2022
19 Jul 2022
12 Jul 2022
19 Jul 2022
12 Jul 2022
Amount
Reinstallation, Testing and Commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition.UL 864 10th Edition and FM Approved.( In case FAS Panel does not have Degrade Feature, Bidder to supply 1 no of extra CPU) Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Active Type Repeater Panel with minimum 600 character LCD Display, with onboard input, output and status indicators to support diagnostics.Rubberrized keypad, having features like Acknowledge, signal silence, system reset, drill, lamp test, fire alarm, security etc. UL & FM Approved Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Addressable Photoelectric Smoke Detector with sensitivity range of 0.5 to 4.0% obs/ft. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Make- Honeywell Notifier
Reinstallation, Testing and commissioning of Addressable Rate of Rise Heat Detector rated at 9.4 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. UL & FM Approved Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of Reinstallation & maintenance. UL and FM Approved Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of Reinstallation & maintenance. UL and FM Approved Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of Reinstallation & maintenance. UL and FM Approved Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Addressable Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of Reinstallation & maintenance. UL and FM Approved Make - Honeywell Notifier
Reinstallation, Testing and Commissioning of Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. UL ApprovedMake - Honeywell Notifier
Loop testing and commissiong of complete system installed.
Supply, Reinstallation, Testing and Commissioning of Addressable Photoelectric Smoke Detector with sensitivity range of 0.5 to 4.0% obs/ft. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition & FM Approved. Make - Honeywell Notifier
Supply, Reinstallation testing and commissionign of addressable Dual Action Manual Pull Station with reset lock & key arrafgement with mounting accessories MCP shall be fitted with transparent hinged ocvers to avoid the possibility of accidental operation. (shall consists of a preapproved, clear, tamper-proof, tough polycabonatecover and frame that retrofits over the Pull Stations. Make - Honeywell Notifier.
Saar Technologies
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .