Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
5 Oct 2023, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
SPECIAL REPAIRS TO COLD STORAGE UNITS (OLD) IN P-14 BLDG AT BV YARD AND PROVISION OF AIR CONDITIONING IN SERVER ROOM AT HQ 33 WEU KOCHI
2023_MES_592086_4
8232/E8
Open Tender
Civil Works
Item Rate
180 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹85,000
Yes
22 Nov 2023
22 Sept 2023
7 Oct 2023
22 Sept 2023
5 Oct 2023
23 Sept 2023
Amount
Material and labour for dismantling existing electrical connections, control cables, copper piping between indoor and outdoor units and repairing the existing Bitzer make with model S4G-12.2Y condensing unit of capacity 48000BTU cold storage to maintain (-30°C) at Blast freezer room with replacement of defective spares to made functioning including testing to attain desired temperature all as directed by Engineer in Charge. Notes:- (i) The entire repair work shall be carried out through OEM/authorized agency. (ii) Necessary PCC/MS foundations for indoor and outdoor units all as per site requirements and OEM specifications. The cost required for the same shall be deemed to be included in the unit cost. (iii) Any minor spares/special items/accessories left out in the contract for successful completion of work shall be provided by the contractor and the cost for the same deemed to be included in the unit cost. (iv) Any Additional modification if required, the contractor shall be liable to transport the item to authorised workshop for modification to make energy efficient and eco friendly system. The cost for the same deemed to be included in the unit cost. (v) Major spare parts shall be measured and paid separately under relevant item in BOQ.
Supply & Fix Air cooled fin and tube condenser of Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain(-30°C) all as specified and directed.
Supply & Fix outdoor Fans with base skid of Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain(-30°C) all as specified and directed.
Supply & Fix Liquid receiver of Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) all as specified and directed by Engineer in charge.
Supply & Fix Liquid sub cooler of Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) all as specified and directed by Engineer in charge.
Supply & Fix Electronic motor protection module of Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) all as specified and directed.
Supply & Fix differential pressure switch for Oil of Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) all as specified and directed.
Supply & Fix compressor BITZER make with model S4G-12.2Y of capacity as fixing to suitable to (-30°C) of 48000BTU/hr capacity compatible with existing unit, including all connected items and made suitable for Eco friendly gas with first charging of gas complete all as specified and directed.
Supply & Fix dryer filter at discharge lines of Outdoor condensing units Bitzer make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) complete all as specified and directed.
Supply & Fix temperature controller for (-30°C) of 48000BTU/hour units all as specified and directed.
Material and labour for repairing indoor unit (evaporator) make: Bhon/ Bluestar/ Recommended by OEM compatible with Bitzer compressor make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) with following replacement of spares for making working condition with replacement of defective spares to make functioning and made suitable for Eco friendly gas complete all as specified and directed.
Supply and fixing in replacement of indoor cover of the unit suitable with existing unit make: Bhon/ Bluestar/ Recommended by OEM compatible with Bitzer compressor make with model S4G-12.2Y of capacity 48000BTU cold storage to maintain (-30°C) recommended by OEM complete all as specified and directed.
Material and labour for replacement of Coil heater for 48000BTU cold storage to maintain (-30°C) complete all as specified and directed.
Material and labour for replacement of evaporator coil of existing units of cooling capacity (-30°C) to maintain inside the meat room suitable to outdoor unit of Bitzer make with model S4G-12.2Y complete all as specified and directed.
Supply and fixing in replacement of Indoor unit Fan motor as fixing to suitable to outdoor unit of Bitzer make with model S4G-12.2Y run with 3 Ph including all connected items complete all as specified and directed.
Supply and fixing in replacement of drain pipes heavy grade as fixing to indoor unit including all connected items complete all as specified and directed.
Supply and fixing in replacement of tray heater as fixing to suitable to outdoor unit of Bitzer make with model S4G-12.2Y including all connected items complete all as specified and directed.
Material and labour for replacement of sub zero temperature controller of to outdoor unit of Bitzer make with model S4G-12.2Y of 48000BTU/hour capacity unit, complete all as specified and directed.
Material and labour for replacement of Drain heater including heavy gazed GI pipe of size 50mm to outdoor unit of Bitzer make with model S4G-12.2Y of 48000BTU/hour capacity unit complete all as specified and directed.
Material & Labour for Replacement of Powder coated Electrical Cabinet of sheet thickness of 16 SWG controller panels for operation indoor, outdoor units for Bitzer make with model S4G-12.2Y of capacity 48000 BTU/hour and Bhon Make indoor for all operations (cooling, heating, defrosting, auto cut off etc) with all controller, contractors, MCBs, OLRs, Timer and Suitable sizes of cables as Recommended by Bitzer. Note: Above Electrical Panel contains the following items (i) Single phase preventer with UV/OV protection (ii) Digital imported temperature display, (iii) Digital timer& 24 Hr time (iv) LED indicators and Copper cables sheathed of adequate size and capacity from control panel to condensing unit and between condensing and evaporator units lay on Cable tray support with Cable glands as per OEM recommendation & all as directed by Engineer in Charge.
Dismantling of unserviceable SS PUF Insulation and leveling the room surfaces by using proper Tools & Plants for Cold storage room and supply and fixing of PUF insulation for Thickness Up to 150MM having SS 304 grade panel cover with thickness 0.4/0.5mm ,Density 40 Kg/M³ by OEM and all as directed. Note: - Work should be carried out by OEM/authorised agency as per standard procedures.
Dismantling existing SS PUF panel and leveling the room surfaces by using proper Tools & Plants and cleaning of SS panels by using OEM recommended chemical solution after removing rust/ foreign particles and refixing after necessary repairs of panel, patchwork and refixing using OEM recommended adhesive, replacement of inter locking system and fixing the joints with silicon to ensure leak proof and complete all as specified and directed.
Supply and fixing in replacement of indoor cooling coil as fixing to suitable to (-18°C) condenser coil of Bluestar make of 50000BTU/hour capacity unit including all connected items complete all as specified and directed.
Supply and fixing in replacement of indoor cover for the existing cooling coil as fixing to suitable to (-18°C) condenser coil of Bluestar make of 50000BTU/hour capacity recommended by OEM complete all as specified and directed.
Supply and fixing in replacement of indoor fan motor of 400mm dia as fixing to suitable to (-18°C) Bluestar make of 50000BTU/hour capacity unit with all connected items complete all as specified and directed
Supply and fixing in replacement of Outdoor fan motor as fixing to suitable to (-18°C) condenser coil of Danfoss make of 50000BTU/hour capacity unit with 3 Ph including all connected items complete all as specified and directed.
Supply and fixing in replacement of condenser coil as fixing to suitable to (-18°C) condenser coil of Danfoss make of 50000BTU/hour capacity unit with including all connected items and made suitable for Eco friendly gas complete all as specified and directed
Supply and fixing in replacement of compressor Danfoss NTZ271 as fixing to suitable to (-18°C) of 50000BTU/hr capacity unit with including all connected items and made suitable for Eco friendly gas complete all as specified and directed
Material and labour for replacement of Drain heater from make Bluestar of 50000 BTU/hour cooling capacity (-18°C) indoor units of complete all as specified and directed
Material and labour for replacement of Coil heater from make Bluestar of 50000 BTU/hour cooling capacity (-18°C) complete all as specified and directed
Material and labour for replacement of dryer filter at discharge lines of Outdoor condensing units make Danfoss of 50000 BTU/hour cooling capacity (-18°C) complete all as specified and directed.
Supply & Fix Refrigerant Gas R 404 A in sealed cylinder, all as specified and as directed.
Supply and fixing of temperature controller make - Subzero CR205200 of 50000 BTU/hour cooling capacity (-18°C) of all as specified and as directed.
Material and labour for repairing indoor cooling coil of existing Bluestar Make units of cooling capacity (+ 4°C) of 20000BTU/hour to maintain inside Egg storage room and replacement of indoor cover suitable with existing unit complete all as specified and directed.
Supply and fixing in replacement of indoor cover for the existing indoor Bluestar Make units of cooling capacity (+ 4°C) of 20000BTU/hour capacity recommended by OEM complete all as specified and directed.
Supply and fixing in replacement of Indoor unit Fan motor with 450 mm dia as fixing to suitable for Blue star Make of cooling capacity (+ 4°C) of 20000 BTU/hour to run with 3 Phase including all connected items complete all as specified and directed by Eng - in - charge.
Dismantling and taking down in replacement of Outdoor fan motor as fixing to suitable in existing condenser coil of Bluestar make of (+ 4°C) of 20000BTU/hour capacity unit with 3 Phase including all connected items complete and made suitable for Eco friendly gas all as specified and directed.
Supply and fixing in replacement of Outdoor condenser coil as fixing to suitable in existing Bluestar make unit of (+ 4°C) of 20000BTU/hr capacity unit with 3 Ph including all connected items complete and made suitable for Eco friendly gas and all as specified and directed.
Supply & Fix Emerson Scroll compressor as fixing to suitable to (+4°C) of 20000BTU/hour capacity compatible with existing unit, including all connected items and made suitable for Eco friendly gas with first charging of gas complete all as specified and directed.
Material and labour for replacement of dryer filter at discharge lines of Outdoor condensing units of capacity (+ 4°C) of 20000BTU/hour complete all as specified and directed.
Supply & Fix Eco friendly Refrigerant Gas in sealed cylinder complete all as specified and as directed.
Supply and fixing temperature controller for (+ 4°C) of 20000BTU/hr units all as specified and as directed.
Dismantling and taking down in replacement indoor cooling coil of existing Bluestar Make units of cooling capacity (+ 4°C) of 30000BTU/hour to maintain inside Vegetable storage room complete all as specified and directed.
Supply and fixing in replacement of indoor cover for the existing indoor cooling coil of existing Bluestar Make units of cooling capacity (+ 4°C) of 30000BTU/hr capacity recommended by OEM complete all as specified and directed.
Supply and fixing in replacement of Indoor fan motor with dia 300mm of positive temperature unit up to + 4°C as fixing to suitable in existing Indoor fan motor of Bluestar make of 30000BTU/hour capacity unit all as specified and directed.
Supply and fixing in replacement of outdoor fan motor of positive temperature unit upto + 4°C as fixing to suitable in existing outdoor fan motor of Bluestar make of 30000 BTU/hour capacity unit all as specified and directed.
Supply and fixing in replacement of Condenser coil of positive temperature unit upto + 4°C as fixing to suitable in existing Condenser coil of Bluestar make of 30000 BTU/hour capacity unit and made suitable for Eco friendly gas all as specified and directed.
Supply & Fix Emerson model - ZB29KQE compressor as fixing to suitable to (+4°C) of 30000BTU/hour capacity compatible with existing unit, including all connected items and made suitable for Eco friendly gas with first charging of gas complete all as specified and directed.
Supply and fixing in replacement of Dryer heater make Danfoss of positive temperature unit upto + 4°C as fixing to suitable in existing Drier heater of Bluestar make of 30000 BTU/hour capacity unit complete all as specified and directed.
Supply and Fill Eco friendly gas for positive temperature unit up to + 4°C of capacity 300000BTU/hour complete all as specified and directed.
Supply and fixing in replacement of Temperature controller of positive temperature unit upto + 4°C as fixing to suitable in existing Temperature controller of Bluestar make of 30000 BTU/hr capacity unit all as specified and directed.
Supply and fixing in replacement of suitable Copper pipes of various sizes for Suction and discharge lines between indoor and outdoor units of -30°C &-18°C with insulation as recommended by OEM complete all as specified and directed. Note: Suction & Discharge lines shall be treated as one Unit for One RM & lay on Cable tray support with Cable glands
Supply and fixing in replacement of suitable Copper pipes of various sizes for Suction and discharge lines between indoor and outdoor units of + 4°C with insulation recommended by OEM complete all as specified and directed by Eng - in - charge. Note: Suction & Discharge lines shall be treated as one Unit for One RM & lay on Cable tray support with Cable glands.
Supply and replacement of premium Quality rubber door gasket for existing Metaflex make door sizes 2000 mm (L)x1200 mm (B), (thickness range of door 100 mm to 150 mm) ,including all connected items for cold rooms complete all as specified and directed.
Supply & Fix Door handle suitable for temperature range -18 °C to -30 °C cold rooms complete all as specified and directed.
Supply and fixing in replacement of weather proof LED tube lights,230Volt,along with copper cable as required for connecting existing points at inside cold rooms complete all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, buried directly and vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with and including galvanised iron wire 4.0 mm (Up to length of 7.5Mtr wire including) by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch/pumps/AC plants units etc as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia complete all as specified and directed
Supply & Fix Log data digital meter for showing minimum past 24 hrs data by Bar chart/Histogram/Pie chart Etc., through connected monitor/ data collection through pen drive showing all combined data of cool and cold storage units complete all as specified and directed
Supply & Fix Hooter with emergency switch connected with electrical lines suitable to withstand indoor temperatures as specified and directed.
Dismantling of old electrical sub main wiring & DB all as directed by Engineer in charge as per the site condition complete.
Material & Labour for sub main wiring with 3 runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 10 Sqmm PVC insulated FRLS cable as earth continuity wire all as specified and as directed. Note: two runs of 4Sqmm and PVC conduit shall be measured as one length.
Supply & Fix in existing MCB DBs, MCB "B" curve 40 Amp SPN, 240 volts complete all as specified and directed.
Supply & Fix in existing MCB DBs, MCB "B" curve SP 6 to 32 Amp, 240 volts complete all as specified and directed.
Supply, install, testing and commissioning of split air conditioning unit 1.5 TR capacity Inverter type, complete with cordless remote control, minimum 5 star labeled latest model eco friendly refrigerant gas, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand as site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipes with refrigerant including with nitrile rubber insulation and control cable from indoor to outdoor as required at site, Power cabling from Isolator/ Enclosure to unit, first charging of refrigerant gas, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply & Fix 4 KVA capacity Voltage stabilizer, copper wounded suitable for 1.5 TR Inverter Split AC automatic operation single phase naturally air cooled indoor type & designed for input variation between 130 to 300 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and speed of correction 8 V per second, fixed on wall with necessary arrangement complete all as specified and directed
Material & Labour for sub main wiring with 2 runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 4 Sqmm PVC insulated FRLS cable as earth continuity wire all as specified and as directed. Note: Three runs of 4 Sqmm, and one run of PVC conduit shall be measured as one length.
Supply & Fix Single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp at 240 volts complete all as specified and directed
Supply & Fix MCB SP, 6 to 32 Amp C curve, 240 Volt, 10 KA complete all as specified and directed
Supply & Fix 20 mm dia CPVC pipes, SDR-13.5 & plain CPVC SDR 11 fittings, fixed on wall/ceiling with all necessary fittings, solvents complete all as specified and directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
Glacier Cooling Solutions Private Limited
AISWARYA ENTERPRISES
AR Traders
N.O. Antony Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .