| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC GF AKRITI TOWER 19 B VIDHAN SABHA MARG LUCKNOW PIN 226001 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | ₹28.1 L Quoted ₹29.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹31.7 L+₹2.5 L (8.63%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | ₹31.7 L+₹2.5 L (8.63%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹32.6 L+₹3.5 L (11.8%)Rejected-Finance | ₹32.6 L+₹3.5 L (11.8%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹56.6 L+₹27.4 L (94.0%)Rejected-Finance | ₹56.6 L+₹27.4 L (94.0%) | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s Dhapola Elevator and Engineering L2 | Prime Technology L1 | ANNAPURNA ENTERPRISES L3 | M/S GAURI CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. including taking out old unsv cable complete all as specified and as directed. | 145 | RM | 150 ₹21,750 | 125 ₹18,125 | 125 ₹18,125 | 119 ₹17,255 Lowest |
| 2.00 | S&F in renewal of MS flanged pipe of 100mm nominal bore, heavy duty, for multistorey building duly painted with two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer complete all as specified and directed. | 32 | RM | 1,050 ₹33,600 | 975 ₹31,200 Lowest | 1,200 ₹38,400 | 1,999 ₹63,968 |
| 3.00 | S&F in renewal of Butterfly valve, 100 mm dia bore, heavy duty with CI body, liver operated IS-13095 marked including jointing materials i.e rubber gaskets, nuts, bolts etc complete all as specified and directed. | 16 | Each | 2,400 ₹38,400 Lowest | 2,950 ₹47,200 | 3,500 ₹56,000 | 8,999 ₹1,43,984 |
| 4.00 | Supply and fixing in renewal of motor protection relay for capacity 12.5 HP to 15 HP motors, relay scale 8-22 Amps, with inbuilt earth fault protection having features such as overload, earth fault, locked rotor, single phasing, current unbalance, phase sequence reversal, under current, inbuilt CT's (1 A to 88 A), Trip indication, selectable trip class-10A, 10, 20 & 30 as per IEC 947-4-1, Aux. supply 240 V AC complete all as specified and directed. | 7 | Each | 700 ₹4,900 Lowest | 1,500 ₹10,500 | 2,000 ₹14,000 | 5,999 ₹41,993 |
| 5.00 | Supply and fixing in renewal of motor starter timer of suitable size and as per site requirement for pump motor of any capacities starters, complete all as specified and directed. | 7 | Each Job | 1,200 ₹8,400 | 500 ₹3,500 Lowest | 3,500 ₹24,500 | 5,999 ₹41,993 |
| 6.00 | S & F in renewal of 3 phase contactor of suitable size and as per site requirment for pump motor of any capacities starters complete all as specified and directed. | 9 | Each Job | 6,000 ₹54,000 | 3,000 ₹27,000 Lowest | 4,000 ₹36,000 | 3,999 ₹35,991 |
| 7.00 | S&F in renewal of existing single phase preventer complete all as specified and directed. | 21 | Each | 1,800 ₹37,800 | 1,000 ₹21,000 | 900 ₹18,900 Lowest | 999 ₹20,979 |
| 8.00 | Supply only rubber gaskets for flanged joint superior quality for 100 mm dia flanges pipe complete all as specified and directed. | 25 | Each | 30 ₹750 Lowest | 150 ₹3,750 | 120 ₹3,000 | 499 ₹12,475 |
| 9.00 | Supply only rubber gaskets for flanged joint superior quality for 80 mm dia flanges pipe complete all as specified and directed. | 82 | Each | 30 ₹2,460 Lowest | 100 ₹8,200 | 120 ₹9,840 | 299 ₹24,518 |
| 10.00 | Dismantling carefully the AC electric motors of capacity upto 12.5 HP induction type, three phase, from the foundation, cutting down and removing the old burnt winding wire from the motor unit, rewinding the same with new super enameled copper winding wire as per existing size/gauge of wire, providing necessary insulation by varnishing and drying the same upto specific temperature of heat, replacing insulation paper sleeves with connecting insulating material, tapping and providing necessary connection to the motors assembly reinstalling, commissioning and testing the pumping set upto good working performance complete all as specified and directed. | 8 | Each Job | 14,000 ₹1,12,000 | 8,500 ₹68,000 | 7,800 ₹62,400 Lowest | 19,999 ₹1,59,992 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
25 Jun 2026, 6:00 pmClosed
Sh Rakesh Birla, EE
GE KOTA Pin-324001
REPAIR/MAINTENANCE OF FIRE HYDRANT AND FIRE FIGHTING SYSTEM AT MIL STN KOTA
2026_MES_769803_1
9063E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Mil Stn Kota
As per tender documents
8 documents required · 8 mandatory
₹500
GE KOTA
₹60,000
Yes
28 Aug 2026
4 Jun 2026
1 Jul 2026
4 Jun 2026
25 Jun 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. including taking out old unsv cable complete all as specified and as directed. | 145 | RM | - | - |
| 2 | S&F in renewal of MS flanged pipe of 100mm nominal bore, heavy duty, for multistorey building duly painted with two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer complete all as specified and directed. | 32 | RM | - | - |
| 3 | S&F in renewal of Butterfly valve, 100 mm dia bore, heavy duty with CI body, liver operated IS-13095 marked including jointing materials i.e rubber gaskets, nuts, bolts etc complete all as specified and directed. | 16 | Each | - | - |
| 4 | Supply and fixing in renewal of motor protection relay for capacity 12.5 HP to 15 HP motors, relay scale 8-22 Amps, with inbuilt earth fault protection having features such as overload, earth fault, locked rotor, single phasing, current unbalance, phase sequence reversal, under current, inbuilt CT's (1 A to 88 A), Trip indication, selectable trip class-10A, 10, 20 & 30 as per IEC 947-4-1, Aux. supply 240 V AC complete all as specified and directed. | 7 | Each | - | - |
| 5 | Supply and fixing in renewal of motor starter timer of suitable size and as per site requirement for pump motor of any capacities starters, complete all as specified and directed. | 7 | Each Job | - | - |
| 6 | S & F in renewal of 3 phase contactor of suitable size and as per site requirment for pump motor of any capacities starters complete all as specified and directed. | 9 | Each Job | - | - |
| 7 | S&F in renewal of existing single phase preventer complete all as specified and directed. | 21 | Each | - | - |
| 8 | Supply only rubber gaskets for flanged joint superior quality for 100 mm dia flanges pipe complete all as specified and directed. | 25 | Each | - | - |
| 9 | Supply only rubber gaskets for flanged joint superior quality for 80 mm dia flanges pipe complete all as specified and directed. | 82 | Each | - | - |
| 10 | Dismantling carefully the AC electric motors of capacity upto 12.5 HP induction type, three phase, from the foundation, cutting down and removing the old burnt winding wire from the motor unit, rewinding the same with new super enameled copper winding wire as per existing size/gauge of wire, providing necessary insulation by varnishing and drying the same upto specific temperature of heat, replacing insulation paper sleeves with connecting insulating material, tapping and providing necessary connection to the motors assembly reinstalling, commissioning and testing the pumping set upto good working performance complete all as specified and directed. | 8 | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender.pdf
Tender Documents • 0.73 MB
BOQ_862064.xls
BOQ • 2.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .