Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC DEHRADUN | L1 | Accepted-AOC 1st Lowest, Reasonable Rate | |
| 2 | L2₹7.5 L+₹24,550.94 (3.39%)Rejected-Finance 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-Finance L2 BIDDER | |
| 3 | L3₹7.6 L+₹32,791.42 (4.53%)Rejected-Finance INDEX NO E 72 HQ CWE HILLS VILL PO MEHUWALA MAPHI NEAR RAJKIYA INTER COLLEGE DEHRADUN UK | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance L3 BIDDER | |
| 4 | L4₹7.6 L+₹41,400 (5.72%)Rejected-Finance 54 10 C JAI DEVI NAGAR MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L4 | Rejected-Finance L4 BIDDER | |
| 5 | L5₹7.8 L+₹56,671.27 (7.83%)Rejected-Finance DEHRADUN | L5 | Rejected-Finance L5 BIDDER |
Tender Value
Refer Docs
EMD Value
₹19,950
Closing Date
11 Aug 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Raiwala
AGE(I) Raiwala
REPAIRS REPLACEMENT OF ROOF LEAKAGE AND ALLIED WORKS AT RAIWALA MIL STN
2023_MES_606819_2
8903/E8
Open Tender
Civil Works
Works
180 days
AGE(I Raiwala
As per tender documents
8 documents required · 8 mandatory
₹500
AGE(I) Raiwala
₹19,950
Yes
22 Sept 2023
25 Jul 2023
12 Aug 2023
25 Jul 2023
11 Aug 2023
29 Jul 2023
25 Jul 2023 - 27 Jul 2023
Amount
Demolition of existing roof treatment i.e APP membrane incl cement screed, brick tiling incl mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material and removing unserviceable material, outside of A 1 defence land complete all as specified and directed. The work will be measured only after stage passing by AGE (I). Note: - (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items. all as specified and directed
Removal of existing roof treatment i.e APP membrane incl cement screed and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material and removing unserviceable material, outside of A 1 defence land complete all as specified and directed. The work will be measured only after stage passing by AGE (I). Note: - (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items. all as specified and directed
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof padding complete as per direction of Engr-in-Charge.. Note :- 1. Liquid water proofing compound will be measured and paid separately. 2. The work is required to be carried out at non-accessible roof for double storey The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.
Supply only Liquid intergal water proofing compoud
M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface. Note :- (i)The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these items.
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only. 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings.
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws complete all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall and gutter, fixed with self tapping screws complete all as specified and directed .
Dismantling mild steel work of any description not otherwise provided for
S & F Rolled Mild Steel sections confirming to Fe 410 - W as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates
S & F Mild steel work in hand rails, wind ties, as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
M&L preparation of old painted steel surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed .
Dismantling of cast iron or reinforced concrete drain pipes up to 100mm dia , jointed in cement mortar and taking out of trenches if required .
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S & F 75 mm bore PVC (SWR) bends of any radius
S & F 75 mm bore PVC (SWR) bends of any radius with access door
S & F 110 mm bore PVC (SWR) bends of any radius
S & F 110 mm bore PVC (SWR) bends of any radius with access door
S & F 110 mm PVC (SWR) WC connector with lip ring.
S & F PVC (SWR) reducers of size 110 mm x75 mm
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 75 mm bore PVC (SWR) Vent Cowl
S&F in repair stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe, complete all as specified and directed.
S&F in repair stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 75 mm pipe, complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick work
Taking down cement plaster in any thickness from brick or stone walls , ceiling, facia etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L Rendering 15 mm thick in CM 1:4 on brick / concrete walls surface, ceiling ,RCC facia and shaft area of toilets mixed with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ) . Note - (SBR) Latex liquid polymer rates quoted shall deemed to be included for these items. Note :- The work is required to be carried out upto double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach up torequired height . The rates quoted shall deemed to be included for these items .
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls surfaces in CM 1:6 finished to even & smooth without using extra cement.
M&L preparation of new or plastered or unplastered and applying two coat of distemper acrylic oil emulsion white or tinted over and incl of one coat of alkali resistance priming paint on wall surface.Complete all as specified and directed
M&L preparation of old plastered or unplastered and applying two coat of distemper acrylic emulsion white or tinted over and incl of one coat of alkali resistance priming paint on wall surface.Complete all as specified and directed
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 500 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
Disconnecting existing tanks 500 but n. exc 1000 ltrs, setting aside (or lowering if required) for repairs etc required reconnecting and re-fixing in position with all sutiable fitting.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
M & L for for shifting aside of MS monkey case of any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site and as directed by Engr-in-Charge
S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs.
AMARJEET SINGH AND CO.
M/s RK ENTERPRISES
Punit Jain
Malik Associates
TARUN ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .