Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹17.3 L+₹90,599 (5.51%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹18.4 L+₹2.0 L (11.9%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹21.4 L+₹5.0 L (30.5%)Rejected-Finance | L4 | Rejected-Finance other than lowest |
| Sl No | Description | Qty | Unit | M/S SANGA SINGH AND CO L2 | shri ram enterprises L3 | R G ENTERPRISES L1 | JASSI TRADERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00Sch 'A' | |||||||
| 1.01Attending faults on call basis/requirement for normal repairs including replacement of defective & worn out parts by new spares such as filters, gaskets, V belts, Engine oil, rubber hoses, worm drive clamps, nut bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking of oil and coolant levels for the undermentioned DG sets complete all as specified and directed. Note : Spares required for above maintenance will be measured and paid separately under relevant item/parts. | |||||||
| 1.02 | DG Set 100 KVA | 4 | Each | 1,999 ₹7,996 | 500 ₹2,000 Lowest | 1,000 ₹4,000 | 1,500 ₹6,000 |
| 1.03 | DG Set 82.5 KVA | 4 | Each | 1,999 ₹7,996 | 500 ₹2,000 Lowest | 1,000 ₹4,000 | 1,400 ₹5,600 |
| 1.04 | DG Set 62.5 KVA | 8 | Each | 1,799 ₹14,392 | 500 ₹4,000 Lowest | 1,000 ₹8,000 | 1,200 ₹9,600 |
| 1.05 | DG Set 40 KVA | 6 | Each | 1,499 ₹8,994 | 500 ₹3,000 Lowest | 1,000 ₹6,000 | 1,000 ₹6,000 |
| 1.06 | DG Set 30 KVA | 6 | Each | 1,299 ₹7,794 | 500 ₹3,000 Lowest | 1,000 ₹6,000 | 900 ₹5,400 |
| 1.07 | DG Set 20 KVA | 4 | Each | 999 ₹3,996 | 400 ₹1,600 Lowest | 1,000 ₹4,000 | 800 ₹3,200 |
| 1.08 | DG Set 15 KVA | 5 | Each | 999 ₹4,995 | 400 ₹2,000 Lowest | 800 ₹4,000 | 750 ₹3,750 |
| 1.09 | DG Set 10 KVA | 4 | Each | 999 ₹3,996 | 400 ₹1,600 Lowest | 800 ₹3,200 | 700 ₹2,800 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Mar 2026, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
COMPREHENSIVE MAINT OF E/M MACHINES AND MISC AND ALLIED WORKS UNDER GE LUDHIANA.
2026_MES_754646_1
GE/LDH-92/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dholewal, CgComplex, Doraha, Baddowal and Moga
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹40,000
Yes
27 Apr 2026
27 Feb 2026
21 Mar 2026
27 Feb 2026
19 Mar 2026
13 Mar 2026
27 Feb 2026 - 12 Mar 2026
Attending faults on call basis/requirement for normal repairs including replacement of defective & worn out parts by new spares such as filters, gaskets, V belts, Engine oil, rubber hoses, worm drive clamps, nut bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking of oil and coolant levels for the undermentioned DG sets complete all as specified and directed. Note : Spares required for above maintenance will be measured and paid separately under relevant item/parts.
DG Set 100 KVA
DG Set 82.5 KVA
DG Set 62.5 KVA
DG Set 40 KVA
DG Set 30 KVA
DG Set 20 KVA
DG Set 15 KVA
DG Set 10 KVA
DG Set 7.5 KVA
S&F in replacement diesel filter element with 'O' ring for DG set of capacity 100/82.5 KVA complete all as specified and directed .
All as per item No. 2 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
All as per item No. 2 above but DG set of capacity 7.5 to 30 KVA complete all as specified and directed .
S&F in replacement lubricating oil filter DG set of capacity 100/82.5 KVA complete all as specified and directed .
All as per item No.5 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
All as per item No.5 above but DG set of capacity 7.5 to 30 KVA complete all as specified and directed .
S&F in replacement by- pass filter element Gen set of capacity 100/82.5 KVA complete all as specified and directed .
All as per item No.8 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
All as per item No.8 above but DG set of capacity 7.5 to 30 KVA complete all as specified and directed .
S&F in replacement air cleaner element (inner) for DG set of capacity 100/82.5 KVA complete all as specified and directed .
All as per item No.11 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
S&F in replacement air cleaner element (Outer) for DG set of capacity 100/82.5 KVA complete all as specified and directed .
All as per item No.13 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
All as per item No. 13 above but DG set of capacity 7.5 to 30 KVA complete all as specified and directed .
Dismantling and repair to self starter assembly 24 volt DC for DG set 100/82.5 KVA including rewinding of armature, replacement of carbon brush, bearing and worn out nut bolts etc and refixing all as original including testing complete all as specified and directed.
All as per item No.16 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
All as per item No.16 above but DG set of capacity 7.5 to 30 KVA complete all as specified and directed .
Dismantling of water pump assembly for DG set 100/82.5 KVA, reparing the same including replacement of water body repair kit, water seal and worn out nuts, bolts, gasket etc and refixing & testing complete all as specified and directed.
All as per item No.19 above but DG set of capacity 40 to 62.5 KVA complete all as specified and directed .
All as per item No.19 above but DG set of capacity 7.5 to 30 KVA complete all as specified and directed .
S&F in replacement Automatic battery charger, 24 V DC, 10 A complete complete all as specified and directed.
S&F evaporative air cooler (desert cooler) of capacity 4000 Cum/Hr discharge in steel body made out of sheet 18 SWG for main body and side covers duly painted with two coats of hammer tone paint 1st quality over a coat of red oxide primer complete inner and outer side with front grill made out of steel (heavy duty) , propeller cooler fan (aluminium blades) 500mm sweep dia with motor , AC single phase , copper wound complete all as specified and directed.
M& L for Sub main wiring for circuit/submain wiring in PVC Conduit along with earth wire with 2x1.5 sqmm + 01 x1.5 sqmm as earth wire of FRLS PVC insulated copper conductor multistranded (ISI marked) complete all as specified and directed.
Supply only calcium hypochlorite having 60% to 70% available chlorine must contain appropriate quantities of dispersants/corroson inhibitor to prevent encrustation/scaling in distribution system Note contractor supplier must submit govt lab test report of calcium hypochlorite alonbgwith each delivery, packed in 45 KG plastic drum complete all as specified & directed .
S&F in replacement on load Changeover Switch 415 V, 4 pole of capacity 63 Amps complete all as specified and directed.
S&F in replacement Over load relay 16 to 100 Amps, 415 V complete all as specified and directed.
S&F in replacement Single phase preventor suitable for motor starter VSP-3 etc complete all as specified and directed.
S&F in repairs MPRO (motor protection Relay ) Protection of Overload/Phase loss/Locked rotor/stall/phase resersal/current unbalance / Short circuit/under current/Earth fault (Residual/CBCT) Over temperature,external fault rating upto 03 to 12.5 HP Motors , 3 Phase, 415 volt connect with motor starter panel complete all as specified and directed. Make BCH/Schnider/L&T or equivalent. Note : Dismantling of old relay and placement of new one should be compatible with existing panel & rate of all deemed to be included.
S&F in replacement AVR for alternator suitable 7.5 kva to 82.5 kva DG Set as per existing model or make complete all as specified and directed.
S&F in replacement VMR relay for AMF suitable for 7.5 KVA to 82.5 KVA DG Set as per existing model or make complete all as specified.
M&L for provn for restoration and ensuring operational reliability of the existing sewage well installation by way of replacement of Non-cloging Submersible pump set 10 HP 3 Phase 50 Hz 415 volt indicating associated motor starter and connected accessories complete all as specified and directed. .Make;kirloskar,Crompton greaves,KSB or equivalent.
Supply and pouring engine oil 15 W 40 for DG Set complete all as specified and directed.
M&L for removing, rewinding and refixing of sewage disposal motor capacity of 5.5 HP at sewage installation, opening of motor,cutting removing old burnt winding coils ,cleaning filling the starter slots necessary mechanical works for shaft/bearing housing/mechnaical seal/volute/ volute base, greasing/oiling all moving parts , rewinding with suitable gauge of super enamelled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing/replacement of pump including replacement of spares , lifting eye bolt, cable gland, protection tube, cable seal, terminal board, cable bracket, brearing cover, double mechanical seal,tie for stand,support bracket, guide shoe, moisture sensor, potting cup, Gland iron box,S & F Duck foot bend, hose clip ball bearings, thermal over load protector, hose nipple, shaft bleaching, two coats of synthetic enamel spray painting on body , suitable mains connections from coil to terminal box,preparing and inserting coil running/starting winding interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and for transportation, testing at site and satisfactorily running complete all as specified and directed. Note :- (a) Lifting the moter & lowering after reapir shall be arranged by the contractor without any extra cost. (b) Transportaion form site to workshop and back to site shall be included in quoted rates.
All as per srl item No 34 above but motor capacity 7.5 HP complete all as specified and directed.
All as per srl item No 34 above but motor capacity 10 HP complete all as specified and directed.
All as per srl item No 34 above but motor capacity 12.5 HP complete all as specified and directed.
Material and labour fas in repairs of MS Structure work conforming to Fe-290 Grade E-165, with MS Angle, Fastners, Tie Rods for supporting pipe and pump footing including cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up including applying two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces and a coat of red oxide primer on un-exposed surfaces and fixing complete all as specified and directed
S&F PVC insulated copper cable with cross sectional area 2.5 sqmm, 3 core complete all as specified and directed.
M&L for provn of Industrial Mist Fans Size 26" 270W Max Mist Volume 10 L/H complete all as specified and directed. Make: Cherry Group India (Model No CH 26 N) or equivalent.
A wall mounted electrically operated Climate control unit of capacity 1.5 ton 5 star rating with cordless remote control unit & within built air ionizer and plazma filter for better indoor air quality capable of maintaining desired indoor environmental conditions throughout the year .The system shall be designed to provide temperature regulation in booth cooling and heating moodes through a reversible heat transfer mechanism. The unit shall including an indoor air distribution module and an outdoor heat exchange asssembly interconnected through insulated piping and suitable electrical connections. . Make; Voltas,panasonic,Blue star or equivalent
Taking down old unserviceable pipe line and S&F pipe 100mm bore GI heavy grade with double ends flanged, 4 hole for sewage pump fixing complete with nut bolt and gasket complete all as specified and directed. Notes :- Rates of nut, bolt and rubber washer shall be included in quoted rates
Taking down old unserviceable pipe line and S&F pipe 80 mm bore GI heavy grade with double ends flanged, 4 hole for sewage pump fixing complete with nut bolt and gasket acomplete all as specified and directed. Notes :- Rates of nut, bolt and rubber washer shall be included in quoted rates.
S&F in replacement direct online starter 3 phase , 415 volt , (DOL) in S/S housing with magnetic,thermal overload relay range 10 to 25 Amp complete suitable for electric motor upto 12.5 HP complete all as specified and directed.
Supply and replacement of 1100 volts grade heavy duty PVC insulated flat submerssible cable 6 sqmm, 3 core with copper conductor complete all as specified and directed.
M&L for repairs of Motor starter panel of sewage/STP installations by welding & painting inclding replacement of Over load realy 0 to 63 Amp 415 V, Power Contactor as per existing rating or model, Single phase preventer VSP-03, MPCB for motor protection, Digital multifunctional meter 0-200 Amp- & 415 Volt , Phase indication lamp, complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 160 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal & adj-magnetic type release including taking down old unserviceable MCCBs complete all as specified and directed.
M&L for unplasticised PVC pipes of size 110 mm pressure rating 10 Kg/sqcm and fixed complete to walls ,ceilling or in floors etc including fittings such as socket, bend, elbow, union etc. complete all as specified & directed .
Supply and fixing in replacement of cast iron sluice valve suitable for 100mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed. Note : Rates of nut bolts and rubber gasket for fixing shall be included in quoted rates.
Supply and fixing in replacement of cast iron sluice valve suitable for 80mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed. Note : Rates of nut bolts and rubber gasket for fixing shall be included in quoted rates.
M&L for provn of Industrial coolers 950 RPM/550W Air flow 18000(M3/H) Capacity 200 Ltrs dimension 1135X600X1730MM Make Cherry Group India Model No CH 200B (30") or equivalent
M&L Framed work as in repairs such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for lifting of Submerible type sewage pump ,capacity 10/ 7.5/5.5/3.0 HP and cleaing/removal of waste or chocking material, lowering after making serviceable ,complete all as specified and directed. Note:- Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 40 feet lifting arrangement portable type ) and other lifting arrangement shall be deemed included in quoted rate (b) Minor repair shall be made and including in quoted rates.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tende92202526.pdf
Tender Documents • 0.68 MB
BOQ_845236.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .