Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 CrAccepted-AOC K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹17.7 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹17.9 CrRejected-Finance | ₹17.9 Cr | L2 | Rejected-Finance Other than Lowest bidder |
| 3 | L3₹20.2 CrRejected-Finance | ₹20.2 Cr | L3 | Rejected-Finance Other than Lowest bidder |
| 4 | L4₹20.2 CrRejected-Finance | ₹20.2 Cr | L4 | Rejected-Finance Other than Lowest bidder |
| 5 | L5₹20.8 CrRejected-Finance | ₹20.8 Cr | L5 | Rejected-Finance Other than Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹8.0 L
Closing Date
14 Apr 2021, 6:00 pmClosed
Chief Engineer CG Visakhapatnam
Chief Engineer CG Visakhapatnam 530007
COMPLETION OF BALANCE LEFTOVER WORK FOR PROVISION OF DEVELOPMENT OF BALANCE LAND OF COAST GUARD AND PROVISION OF BALANCE MARRIED ACCOMMODATION AT VISAKHAPATNAM RISK COST CONTRACT AGAINST CA NO CE NAVY VIZ 14 OF 2013 14
2020_MES_386678_3
CE (CG) / VIZ/ TOKEN / 11 OF 2020-21
Open Tender
Civil Works
731 days
Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹3,000
Yes
Assistant Garrison Engineer I CG Visakhapatnam
₹8.0 L
Yes
7 Jun 2021
18 Mar 2021
16 Apr 2021
18 Mar 2021
14 Apr 2021
2 Apr 2021
Amount
Schedule "A" Part – I to Schedule "A" Part – XVII: NOTE: Schedule "A" Part – I to Part – XIV EXCEPT Schedule "A" Part –IIA , Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only Contractor shall insert their rates for Schedule "A" Part –IIA Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII under Green coloured field under Column - 6 only
Lump sum price worked out by the contractor for the “BUILDINGS WORKS”, as listed in Schedule 'A' Part I against the lump sum price of Rs. 6,22,58,900 inserted by MES in Schedule ‘A’ Part-I on Serial Page No. 35
Price worked out by the contractor for "INTERNAL WATER SUPPLY ", against the price of Rs. 4,77,007.07 inserted by MES as listed in Schedule 'A' Part - II on Serial Page No. 40
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY ", against the price of Rs. 2,94,401.80 inserted by MES as listed in Schedule 'A' Part - III on Serial Page No. 42
Price worked out by the contractor for "SITE CLEARANCE/ EARTH WORK / EXCAVATION/DEMOLITION ", against the price of Rs. 14,96,589.51 inserted by MES as listed in Schedule 'A' Part - IV on Serial Page No. 45
Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 16,58,823.19 inserted by MES as listed in Schedule 'A' Part - V on Serial Page No. 47
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 2,52,664.18 inserted by MES as listed in Schedule 'A' Part - VI on Serial Page No. 50
Price worked out by the contractor for "RETAINING WALL", against the price of Rs. 2,27,995.25 inserted by MES as listed in Schedule 'A' Part - VII on Serial Page No. 52
Price worked out by the contractor for "COMPOUND WALL ", against the price of Rs. 74,297.55 inserted by MES as listed in Schedule 'A' Part - VIII on Serial Page No. 55
Price worked out by the contractor for "ROAD/PATH / CULVERT ", against the price of Rs. 11,60,763.64 inserted by MES as listed in Schedule 'A' Part - IX on Serial Page No. 58
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 1,48,722.1 inserted by MES as listed in Schedule 'A' Part - X on Serial Page No. 60
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price of Rs. 3,97,192.48 inserted by MES as listed in Schedule 'A' Part - XI on Serial Page No. 62
Price worked out by the contractor for "INTERNAL FIRE FIGHTING, against the price of Rs. 3,92,224.69 inserted by MES as listed in Schedule 'A' Part - XII on Serial Page No. 63
Price worked out by the contractor for "EXTERNAL FIRE FIGHTING, against the price of Rs. 11,70,459.58 inserted by MES as listed in Schedule 'A' Part - XIII on Serial Page No. 65
Price worked out by the contractor for "LIGHTNING PROTECTION", against the price of Rs. 86,061.10 inserted by MES as listed in Schedule 'A' Part - XIV on Serial Page No. 66
Schedule "A" Part - IA [BUILDING / STRUCTURE WORKS]
Serial No 1 : Completion of the leftover /incomplete work for Construction of a block of sub station building complete all as shown on drawings and as specified.
Serial No 2 : Completion of the leftover /incomplete work for Construction of a block of Pump house building complete all as shown on drawings and as specified.
Serial No 5 : Completion of the leftover /incomplete work for Construction of Scooter shed for 80 Scooters complete all as shown on drawings and as specified.
Serial No 6 : Completion of the leftover /incomplete work for Construction of Septic tank 200 users complete all as shown on drawings and as specified.
Serial No 7 : Completion of the leftover /incomplete work for Construction of Soakage well of internal dia 3Mtr and 4.5 Mtr effective depth complete all as shown on drawings and as specified.
Serial No 8 : Mild steel gate of 5.50 m wide and 2 m high (with wicket gate 0f 1.2m width) made out of mild steel angle iron, mild steel sheet, mild steel square bars, flat including RCC columns, excavation and earth work in any type of soil, painting gates with two coats of synthetic enamel paint over a coat of primer complete all as shown on drawings and as specified. ENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR.
NOTE APPLICABLE TO SRL ITEM NO 8 OF SCH 'A' Pt-IA ENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR.
Schedule "A" Part - XV [MISCELLANEOUS ITEMS TO BE QUOTED BY CONTRACTOR FOR INTERNAL WATER SUPPLY, INTERNAL ELECTRIC SUPPLY, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIC SUPPLY, GEYSER, INTERNAL FIRE FIGHTING, EXTERNAL FIRE FIGHTING, LIGHTNING PROTECTION, AUTOMATIC FIRE ALARM AND DETECTION SYSTEM, DG SET AND AVIATION OBSTRUCTION LIGHT]
Sl No 1 : Point wiring with 1.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral and earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one light point controlled by one switch.
Sl No 2 : All as per Sl No.1 hereinbefore but one fan point controlled by one switch and regulator.
Sl No 3 : All as per Sl No.1 hereinbefore but for one exhaust fan point controlled by one switch.
Sl No 4 : All as per Sl No.1 hereinbefore but for one bell/buzzer point controlled by one push button on the same board with other switches or independent .
Sl No 5 : All as per item No 1 hereinbefore but for 5 amps socket outlet on independent board. .
Sl No 6 : All as per item No. 1 hereinbefore but for stair case wiring one light point controlled by two two way switches. .
Sl No 7 : Point wiring with 2.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral )and 1.5 sq mm cable for earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one 15 Amps power point on independent board. .
Sl No 8 : Electronic regulator stepped socket type for ceiling fan of 1200 mm sweep 120 W single module complete all as specified.
Sl No 9 : Telephone socket with top conector complete all as directed.
Sl No 10 : TV cable outlet complete all as directed.
Sl No 11 : Concealed PVC rigid non metallic conduit heavy grade 20 mm dia with and including one run of 2 mm dia GI wire for drawing TV cable/telephone cable complete all as specified and directed. (Note: 1 run of GI wire and 1 run of PVC conduit shall be measured as one unit)
Sl No 12 : Submain wiring in concealed PVC conduit with two runs of 2.5 sq mm and one run of 1.5 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 20 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. (Note: 2 runs of 2.5 sq mm cable and one run of 1.5 sq mm cable and 1 run of PVC conduit shall be measured as one unit) .
Sl No 13 : Submain wiring in concealed PVC conduit with two runs of 4 sq mm and one run of 2.5 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 25 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified. (Note: 2 runs of 4 sq mm cable and one run of 2.5 sq mm cable and 1 run of PVC conduit shall be measured as one unit) .
Sl No 14 : Submain wiring in concealed PVC conduit with two runs of 6 sq mm and one run of 4 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 20 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. (Note: 2 runs of 6 sq mm cable and one run of 4 sq mm cable and 1 run of PVC conduit shall be measured as one unit) .
Sl No 15 : Submain wiring in concealed PVC conduit with four runs of 10 sq mm and one run of 6 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 40 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. (Note: 4 runs of 10 sq mm cable and one run of 6 sq mm cable and 1 run of PVC conduit shall be measured as one unit)
Sl No 16 : Fluorescent tube light fitting box type 1x36 watt with CRCA steel sheet housing with white reflector cover fitted to the body with electronic ballast including 36/40 watt tube. Cat No. BJCEB 136/140 WEB of Bajaj or equivalent in Havels/ CG/ Philips (Note: Tube rod only will be issued under Sch 'B' free for fixing only)
Sl No 17 : CFL fitting 1x11 watt surface mounting type including 1x11 watt lamp. Cat No. BJC 111 of Bajaj or equivalent in Havels/ CG/ Philips
Sl No 18 : CFL fitting 1x18 watt surface mounting type including 1x18 watt lamp. Cat No. BSP of Bajaj or equivalent in Havels/ CG/ Philips
Sl No 19 : Security light fitting 2X18 watt including GI pipe bracket made out of 25/40mm dia medium grade pipe, MS clamps, nuts, bolts and washers all as specified and directed by Eng-in-charge. Make: Bajaj-Cat No.BJSLF 218 DD CFL or equivalent in CG /Philips / Wipro .
Sl No 20 : MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure double door type complete all as specified. .
Sl No 21 : Fixing only MCB DB SPN 8 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified. Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inserted there. .
Sl No 22 : MCB DB SPN 6 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified.
Sl No 23 : MCB DB SPN 4 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified.
Sl No 24 : MCB DB SPN 2 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified.
Sl No 25 : MCB TPN 0 to 30 amps capacity 415 V complete all as specified.
Sl No 26 : Fixing only MCB SPN 0 to 30 amps capacity 240 V complete all as specified. Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inserted there.
Sl No 27 : MCB SP 0 to 32 amps capacity 240 V complete all as specified.
Sl No 27 A : Fixing only MCB SP 0 to 32 amps capacity 240 V complete all as specified. Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inserted there.
Sl No 28 : Dummy plates for DBs complete all as directed. .
Sl No 29 : Sheet metal enclosure single pole neutral with two pin and earth plug socket complete with single pole MCB of 16 Amps capacity 240 volts AC supply for geyser complete all as specified.
Sl No 30 : Laying only on wall/roof/floor etc with PVC clamps XLPE insulated and PVC bedded galvanised strip armoured heavy duty electrical cable with aluminium conductor 1100 V grade conforming to IS 7098-1974 of 16 sq mm 4 core for service connection complete all as specified. Note : Cable will be issued under Sch 'B' free for laying only)
Sl No 31 : Energy saving electronic type energy meter temper proof type electrically operated 5 to 20 amps capacity AC 3 phase 415 volts complete with LED display conforming to IS-13779 complete all as specified. Make : HPL/HAVELLS/EE/ANCHOR.
Sl No 32 : Energy saving electronic type energy meter temper proof type electrically operated 5 to 20 amps capacity AC single phase 415 volts complete with LED display conforming to IS-13779 complete all as specified. Make : HPL/HAVELLS/EE/ANCHOR.
Sl No 33 : 25x4 mm galvanised iron strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified. .
Sl No 34 : Sheet metal enclosure made out of 2 mm thick mild steel sheet with doors and locking arrangement powder coated, dust and vermin proof, cubical type for housing KWH meter, MCB DBs etc including provision of 20 mm thick wooden plank of suitable size as base duly fixed with nuts and bolts of suitable size complete all as directed. .
Sl No 37 : Fixing only Cubical type bus bar chamber made out of 2 mm thick mild steel sheet, powder caoted with grouting arrangements to wall with provision of door shutter with hinges, locking arrangement etc including 3 Nos of aluminium bus bar of capacity 100 amps for phases and one number bus bar of capacity 50 amps for neutral mounted on PVC/porcelain insulators including arrangements for termination of incoming and outgoing cables/sub main wiring complete all as directed. Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inserted there.
Sl No 38 : Cubical type bus bar chamber made out of 2 mm thick mild steel sheet, powder coated with grouting arrangements to wall with provision of door shutter with hinges, locking arrangement etc including 3 Nos of aluminium bus bar of capacity 50 amps for phases and one number bus bar of capacity 25 amps for neutral mounted on PVC/porcelain insulators including arrangements for termination of incoming and outgoing cables/sub main wiring complete all as directed.
Sl No 39 : Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead of 25x4 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, 32mm dia GI light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
Sl No 40 : 4 mm dia galvanised iron wire continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified. .
Sl No 41 : Fixing only water heater storage type electrically operated 50 litres capacity complete with connecting PVC pipes, CP copper pipe, NRV etc complete all as directed. Note: Water heater will be issued under Sch 'B' free for fixing. .
Sl No 42 : Brass CP mixer for mixing hot and cold water screwed for iron pipe and fixed complete all as specified. .
Sl No 43 : Cutting the existing 150mm dia CI pipe line in position and inserting Tee 150x150x150 mm dia with required specials Note: Unit rate quoted shall include the cost of CI TEE and specials.
Sl No 44 : Ductile iron pipes 150 mm bore spigot socket centrifugally cast (spun) class K-9 with cement mortar lining inside with portland slag cement as per IS 455:1989 and outside metallic zinc coating as per IS conforming to IS-8329 of 2000 or ISO 2531 of 2009 laid in trenches, on floor/walls complete all as specified.
Sl No 45 : Ductile iron pipe fittings (spigot and socketted/flanged ends) such as bends, tees, tapers, short pieces, collors, reducers, flanged blanks/blind etc up to 150 mm bore with cement mortar lining inside with portland slag cement as per IS 455:1989 and outside metallic zinc coating as per IS conforming to IS-8329 of 2000 or ISO 2531 of 2009 complete all as specified.
Sl No 46 : Sluice valve 150 mm dia non raising stainless steel spindle, brass spindle check nut, CI gate body, brass gate ring, brass body ring IS marked IS-1485 PN 1.6 complete including jointing and jointing material complete all as specified.
Sl No 47 : Valve chamber of internal size 1000x1000x1000mm comprising of 100mm thick PCC 1:5:10 type E2 (using 40mm graded stone aggregate) foundation, 230mm thick brick walls in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally upto 150mm below GL, 100 mm thick PCC 1:3:6 type B1(using 20 mm graded stone aggregate) coping, 5mm thick MS sheet cover with suitable hinges and locking arrangement supported on angle iron frame 50x50x6mm, painting steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including necessary excavation and earthwork in any type of soil complete all as specified and directed. .
Sl No 48 : Centrifugal pump set capable of pumping 1200 litres per min at a head of 80 metres conforming to IS, coupled directly through a set of flexible coupling mounted on fabricated MS base plate, driven by and including electric motor squirrel cage induction suitable for operation on 415 V 3 phase, 50 Hz AC synchronous speed not more than 1500 RPM including copper conductor cable with flexible pipe protection from the existing panel mounted star delta starter at common supply to pump motor alongwith pressure gauge on discharge side, gun metal non return valve 50mm bore - 1 No, gun metal gate valve 50mm bore -1 No, flanged type foot valve with strainer etc 100mm -1 No and suitable PCC foundation etc complete all as directed. .
Sl No 49: Cast iron air valves 50 mmm bore with two air outlets and fixing up in cast iron water supply mains complete all as directed. .
Sl No 50 : Addition/extension 11 KV, 630A 21 KA outdoor, extensible type SF6 insulated RMU with two Nos VCB along with protection on relay and CTs Type : FBX-E/T2T2/outdoor manual extensible complete all as directed.
Sl No 51 : Cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor 11000 V grade of size 3 Core 185 Sqmm laid in trenches complete all as specified and directed.
Sl No 52 : Cable jointing kit for 11 KV (E) grade cable for out-door termination cold shrinkable type joint complete with jointing materials and accessories suitable for 3 Core XLPE armoured aluminum conductor cable of size 185 sqmm complete all as specified.
Sl No 53 : Cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and acessories suitable for 3 Core XLPE armoured alumium conductor cable of size 185 Sqmm complete all as specified.
Sl No 64 : MCCB enclosure fabricated indoor wall mounted type compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following:-( For Lift machine room ) (a) MCCB 63 Amps 3 pole 25 KA - 01 Nos(01 for lift) (b) LED indication lamps compact type (R,Y,B) -01 set .
Sl No 64 A : Fixing only MCCB enclosure fabricated indoor wall mounted type compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following:-( For Lift machine room ) (a) MCCB 63 Amps 3 pole 25 KA - 01 Nos(01 for lift) (b) LED indication lamps compact type (R,Y,B) -01 set Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'. .
Sl No 65 : Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 4 mm dia (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel 15mm dia light grade for protection of earth electrode and 20mm dia GI pipe for watering all as speicified and directed and tested on completion.
Sl No 66 : Laying only XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of following sizes complete all as specified and directed. Note: Cable will be issued under Sch 'B' free for laying only
(a) 3.5 Core x 400 sqmm
(b) 3.5 Core x 300 sqmm
(c) 3.5 Core x 240 sqmm
(d) 3.5 Core x 70 sqmm
(e) 3.5 Core x 35 sqmm
(f) 4 Core x 10 sqmm
(g) 2 core x 16 sqmm
(h) 3.5 core x 185 sqmm
(j) 3.5 core x 50 sqmm
(k) 4 core x 25 sqmm
(l) 4 core x 16 sqmm
Sl No 67 : Loop in loop out thermoplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS sheet comprising of MCB SP 6A and 3 porcelain terminals as bus terminals for cable with necessary fixing arrangement, preparing the surface and applying two coats of synthetic enamel paint over a coat of pimer complete all as directed. .
Sl No 68 : Street light fittings Single Piece, Cast AluminiumWith Full Frame Glass Cover Integral Luminaires of model ( Cat No. BGEST 150 SV IP 65 FFG WOB of Bajaj or its equivalent in Philips/CG) and luminarie HPSV T 150W complete including all fixing arrangements to the steet light pole complete all as specified .
Sl No 69 : Taking down the existing LT cable of size 3.5 core 185 sqmm and relaying carefully complete all as directed. .
Sl No 70 : Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 185 sq mm complete all as directed.
Sl No 71 : 57 degree CQBD with required fittings all as per standard practice and as directed with the following specifications (a) Material of construction - High tensile brass forging (b) Heat sensitive bulb - Quartzoid (dia 8 mm) (c) Deflector brass conforming to IS - 319 (d) Test pressure - 30 Kg/sq cm (e) Working pressure - 12.4 Kg/sq cm (f) Bulb Temp, Tange & colour - 57 degree C/135 degree F, Orange (g) Finish - Brass/Nickle & chrome plated (h) Net weight - Not less than 150 Grams
Sl No 72 : Mild steel pipe 150 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed.
Sl No 73 : Mild steel pipe 100 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed.
Sl No 74 : Mild steel pipe 80 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed. .
Sl No 75 : Mild steel pipe 50 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed. .
Sl No 76 : Cast iron flanged sluice valve 150 mm dia class 1.6 PN complete all as specified. .
Sl No 77 :Cast iron flanged sluice valve 100 mm dia class 1.6 PN complete all as specified. .
Sl No 78 : Cast iron flanged sluice valve 80 mm dia class 1.6 PN complete all as specified.
Sl No 79 : Fire alarm valve 80 NB with required fittings all as per standard and as directed Model A size, 80 NB maximum service 12 Bar (175 PSI), pressure threaded opening BSPT (NPT-optional), mounting verticle flange connection ANSL B 161 FF # 125 (optional IS 1538) TRIM Steel with brass valves, factory hydrostatic 25 kg/ sq mm (335 PSI) test pressure frictional loss 80 NB-6.46 Mtr (21.2 ft) of pipe approximate net weight with out trim 80 NB 32 kg, finish - fire red epoxy painted approval UL listed reference NEPA 13 and NEPA 25 complete all as directed.
Sl No 80 : 16 zone UL certified microprocessor based fire alarm panel with TCP-IP provision and zone wise hooters as per IS-2189, 16 zone micro processor based fire alarm panel with 4x20 Alpha numeric LCD display, event logging, real time clock & RS-485 port to connect repeater panel via 4 wires key board programming with pass word locking, provision of RS-232/485 for LAN connection, event storage painted red along with relay contact for public address system. Make : Ravel/Vijay/Notifier
Sl No 81 : 06 zone UL certified microprocessor based fire alarm panel with TCP-IP provision and zone wise as per IS-2189, 06 zone micro processor based fire alarm panel with 4x20 Alpha numeric LCD display, event logging, real time clock & RS-485 port to connect repeater panel via 4 wires key board programming with pass word locking, provision of RS-232/485 for LAN connection, event storage, painted red along with relay contact for public address system. Make : Ravel/Vijay/Notifier
Sl No 82 : Multi zone microprocessor based master fire alarm panel with 4x20 Alpha numeric LCD display, event logging, real time clock & RS - 485 port to connect panel via 2 wires, key board programming with pass word locking, provision of RS - 232/485 for LAN connection, event storage, painted red along with auto dialer to inter connect control room to fire station complete all as directed. Make : Ravel/Vijay/Notifier .
Sl No 83 : Public address system along with centralized communication system at control room complete all as directed. .
Sl No 84 : Heat/smoke detector ionization/ photoelectric type along with required base and junction boxes complete all as directed. Make : Appollo/System sensor/Notifier .
Sl No 85 : Manual call points/break glass switches with LED indication, die cast aluminium round type complete all as directed. Make : Ravel/Vijay/Notifier .
Sl No 86 : Electronic type dual type hooters 100 db complete all as directed. Make : Ravel/Vijay/Notifier
Sl No 87 : 1.5 sq mm 2 core armoured copper cable as per IS 1554 including wall mounting/ceiling mounting with saddles, clamps, screws, junction boxes steel conduit and required cable gland with necessary earthing complete all as directed.
Sl No 88 : Horizontal double mounting type single phase 220/250 volts, 6000 RPM, 500 C/s HP 1/4, range 1.5 KM including necessary cabling complete all as directed. Make : Kheraj/Target
Sl No 89 : Cast iron flanged non return valve 150 mm dia complete all as directed.
Sl No 90 : Cast iron flanged non return valve 100 mm dia complete all as directed. .
Sl No 91 : Fire hydrant valve type A (single outlet) of 63 mm dia conforming to IS - 5290 complete all as directed. .
Sl No 92 : 36 metres long first aid hose reel drum full swing of 18 mm bore as per IS - 884-1985 complete with control and 4.6 mm aluminium nozzle fitted along with enclosure and isolation ball valve complete all as directed. Make : Padmini/CRC .
Sl No 93 : Fire fighting hose 2 x 15 metres long conforming to IS - 636 complete with male and female coupling with copper wire winding conforming to IS - 903 complete all as directed. Make : Padmini/CRC .
Sl No 94 : Hose cabin of size 30"x24"x10" suitable for 2 Nos hose wall/base mounting type fabricated out of mild steel sheet 3 mm thick having glass front door with locking arrangement complete all as directed.
Sl No 95 : 63 mm gun metal branch pipe and nozzle conforming to IS - 903 complete all as directed. Make : Winco/AAG
Sl No 98 : Fixing only Exhaust fan 300mm sweep heavy duty single phase, 230 volts, 50 Hz AC supply including louver shutters all as specified. Note : Exhaust Fan will be issued under Schedule 'B' free for fixing only. .
Sl No 101 : Diesel driven pump auto control panel 180 AH batteries (02 in Nos of 12 volt 180 AH battery maintenance Free type) .
Sl No 102 : Cast iron foot valve 150 mm dia complete all as directed.
Sl No 103 : Cast iron foot valve 100 mm dia complete all as directed.
Sl No 104 : Water pressure gauge standard dia at the delivery side of pump sets complete with connecting tubing fitted with stop cocks etc as per standard practice complete all as directed.
Sl No 105 : Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead of 25x6 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel 32mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
Sl No 106 : Electrically operated water pressure switch with necessary mounting/connection with control wiring with conductor and mechanical connection to operate at pressure range 0 to 10 Kg/Sqcm for automation complete all as directed.
Sl No 107 : 150mm dia 4 way fire brigade inlet without isolation valve and with instantaneous GM couplings, 63mm dia with required fittings all as directed.
(A). Alternator :- Standard design alternator rated at 315 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722 i) Insualation class - 'H‘ ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. vi) Lub oil System : Lubricating oil filter Lubricating oil pump vii) Air Intake System : Air intake Manifold Air cleaner dry type viii) Governor :- Electronic Governor ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice igniton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xii) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiv) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames. xv) Base Frame : - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes xvi) Fuel Tank :- Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure in the sub staion building. xvii) MS pipe line to and from the fuel tank to the DG Set
D) Accoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum) vi) The accoustic should be composite in construction and fully assembled integral unit vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form viii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer. ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings. xi) The noise level should be 75 dba at 1m under free field conditions. xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade.
Sl No 109 : Terrace pump 450 ltrs per minute with minimum pressure of 3 Kg/sqm coupled with an electric motor with complete connections located on terrace connected to terrace tank with non return valve on delivery side, starting of terrace pump shall be automatic with pressure switch incorporated complete all and as directed
Sl No 110 : PVC insulated PVC sheathed cable galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 2.5 sq mm 3 core fixed on walls/roofs with saddles etc complete all specified and directed.
Sl No 111 : Aviation obstruction LED type fixed on and including GI pipe medium grade on top of roof complete all as directed. Make : Philips/ Bajaj/ Havella/K-lite
Sl No 112 : Sheet metal enclosure for DBs single pole & neutral 1 way with our bus bar 240 V complete all as specified.
Sl No 113 : MCB SPN 240 V, 5 to 30 Amps complete all as specified.
Sl No 114 : Transformer step down 11/0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 630 kVA indoor type conforming to IS 2026 with and including the following:- (a) Lifting lugs/hooks for transformer and tank (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level gauge (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335 (j) Type of connection : Delta/Star (k) Type of cooling : ONAN
(l) Vector Group : DYN 11 (m) Type of connecting arrangement : Cable termination boxes on both HT and LT side (n) Temperature rise over an ambient of 50 degree centigrade maximum (o) Provision of thermometer with pocket (p) In addition to the above all standard fittings shall be provided as per IS norms
Sl No 115 : Electro rubber mat 1000 x 2000 x 10mm all as specified.
Sl No 116 : Electro rubber mat 1000 x 2000 x 19mm all as specified.
Sl No 117 : Fire extinguisher DCP 5 Kg capacity
Sl No 118 : Fire buckets 10 ltrs capacity
Sl No 119 : Shock treatment chart board as per standard norms
Sl No 220 : Extra over rendering or plastering for arch elevation work in CM 1:2 50mm wide and 50mm thick all as directed.
Sl No 221 : Extra over rendering or plastering for arch elevation work in CM 1:2 25mm wide and 25mm thick all as directed.
Sl No 222 : Removal of 1300 bags of cement (unfit for onstruction activities) from the work site and disposal of the same outside MOD land or Coast Guard land complying the instructions of the local civil authorities in the matter all as directed.
Schedule "A" Part - XVI (DEFECTIVE/PARTIALLY COMPLETED E/M ITEMS) NOTE:- The contractor who has undertaken the work under CA No CA No : CE(Navy)/Viz/14 of 2013-14 has not executed the items of work, given below , as per the scope given in the contract for the respective item of the work and has left it incomplete / partially executed. The contractor bidding now shall inspect the site of work and make themselves fully familiar about the quantum of work required to be done for successful completion of the respective item as per CA for its functional suitability, and quote their rates accordingly. The payment to the contractor now undertaking this work will be restricted to the rate/amount now quoted and nothing extra is admissible to them on pretext of any misunderstanding. Bidders are advised to go through Annexure 'H' , in addition to the site visit, before quoting their rates.
Sl No 1 : Point wiring with 1.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral and earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one light point controlled by one switch. (Serial item No 1 of Sch A Pt XV)
Sl No 2 : All as per Sl No.1 hereinbefore but one fan point controlled by one switch and regulator. (Serial item No 2 of Sch A Pt XV)
Sl No 3 : All as per Sl No.1 hereinbefore but for one exhaust fan point controlled by one switch. (Serial item No 3 of Sch A Pt XV)
Sl No 4 : All as per item No 1 hereinbefore but for 5 amps socket outlet on independent board. (Serial item No 5 of Sch A Pt XV)
Sl No 5 : Point wiring with 2.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral )and 1.5 sq mm cable for earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one 15 Amps power point on independent board. (Serial item No 7 of Sch A Pt XV)
Sl No 6 : Submain wiring in concealed PVC conduit with two runs of 2.5 sq mm and one run of 1.5 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 20 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. (Note: 2 runs of 2.5 sq mm cable and one run of 1.5 sq mm cable and 1 run of PVC conduit shall be measured as one unit). (Serial item No 12 of Sch A Pt XV)
Sl No 7 : MCB DB SPN 8 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified. (Serial item No 21 of Sch A Pt XV).
Schedule "A" Part - XVII (DEFECTS RECTIFICATION B/R ITEMS) NOTE:- The contractor who has undertaken the work under CA No CA No : CE(Navy)/Viz/14 of 2013-14 has executed the items of work, given below , but defects have cropped up due to poor workmanship for the respective item of the work. The contractor bidding now shall inspect the site of work and make themselves fully familiar about the quantum of work required to be done for successful completion of the respective item as per CA for its functional suitability, and quote their rates accordingly. The payment to the contractor now undertaking this work will be restricted to the rate/amount now quoted and nothing extra is admissible to them on pretext of any misunderstanding.
Sl No 1 : PVC waste pipe found broken at certain places need to be replaced to the satisfaction of Engr-in-Charge. (Block No 1 of Type II & III)
Sl No 2 : Hair line cracks found in plaster at 04 different locations need to be corrected to the satisfaction of Engr-in-Charge. (Block No 1 of Type II & III, Block No 2 of Type II and Near substation and Pump house area)
Sl No 3 : Rebates of door frame not finished properly and required to be done to the satisfaction of Engr-in-Charge. (Block No 1 of Type II & III)
Sl No 4 : Honey combing in RCC parapet wall at certain places needs to be rectified to the satisfaction of Engr-in-Charge. (Block No 2 of Type II)
Sl No 5 : Surface of RCC work not finished properly at certain places needs to be rectified to the satisfaction of Engr-in-Charge. (Block No 2 of Type II)
Sl No 6 : Welding of the gate not done properly and needs to be rectified to the satisfaction of Engr-in-Charge. (Near substation and Pump house area)
Sl No 7 : Rolling shutter not painted needs to be painted as per Sch of finishes to the satisfaction of Engr-in-Charge. (Near substation and Pump house area) .
Sl No 8 : Plinth protection found damaged/broken needs to be rectified to the satisfaction of Engr-in-Charge. (Near substation and Pump house area)
Sl No 9 : Joints in plinth protection not filled properly with filler, needs to be rectified to the satisfaction of Engr-in-Charge. (Near substation and Pump house area)
Sl No 10 : Edges of RCC slab of UG Sumps (2 Nos) found broken at places, needs to be rectified to the satisfaction of Engr-in-Charge. (Near substation and Pump house area)
SVS PROJECTS
M/s Imperial Coastal Infra
Indus Projects Private Limited
Sowrya Constructions
C R R CONSTRUCTIONS
RKEC Projects Limited
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid