| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC MORKANDA ROAD BALNATH NURANI TOWER 2ND FLOOR BLOCK NO 301 JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC L1 REASONABLE | |
| 2 | L2₹22.0 L+₹83,915.20 (3.97%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹22.2 L+₹1.1 L (5.10%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹23.8 L+₹2.6 L (12.5%)Rejected-Finance 234 PKT 8 SEC 12 SURYODAYA APARTMENT DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹23.8 L+₹2.7 L (12.8%)Rejected-Finance MAHARAJA SOCIETY HAPA YARD ROAD NR ALFA PAN STREET NO 6 O S KALWADGET JAMNAGAR GUJ | L5 | Rejected-Finance NOT L1 |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
17 Oct 2023, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
PROVISION OF CERTAIN SANITARY ANNEX TO MIL HOSP, 152 AD REGT, LONG RANGE, SPORTS GRND AND MSI AT MIL STN JAMNAGAR
2023_MES_615710_2
8021
Open Tender
Civil Works
Item Wise
274 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹45,000
5 Dec 2023
3 Oct 2023
19 Oct 2023
4 Oct 2023
17 Oct 2023
9 Oct 2023
Amount
Excavation in trenches n.exc 1.5M wide and n.exc 1.5 M depth for foundation / laying of UG cables / GI pipeline and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge.
Excavation in trenches n.exc 1.5M wide and n.exc 1.5 M depth for foundation / laying of UG cables / GI pipeline and getting out in soft/loose soil soil complete all as specified and directed by Engr-in-charge.
M&L plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation & filling in Mass concrete complete all as specified and directed by Engr-in-chargeby
M&L Pre cast cement concrete block masonary with soild block type C1 1:3:6 (Using 20 mm graded stone aggregate) exc 10 CM in width and setting in CM 1;6 complete all as specified and directed by Engr-in-charge
M&L Providing precast cement concrete solid block masonary type C1 1:3:6 (Using 20 mm graded stone aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4 , complete as in walls complete all as specified and directed by Engr-in-charge
M&L for reinforced cement concrete 1:1.5:3 type A1 (20mm graded stone aggt) (nominal mix) as in lintel, beam, cantilevers, complete all as specified and directed by Engr-in-charge.
M&L RCC 1:1.5:3 type A1 using 20mm graded aggregate as in chajjas complete all as specified and directed by Engr-in-charge
M &L RCC 1:1.5:3 type A1 using 20 mm graded aggregate as in slabs supported on wall., beam and colums in floor and in shelves complete all as specified and directed by Engr-in-charge
Use and waste of formwork to sides & soffits of floor or roof beams,lintel, cantilever, selves including supports etc rough finished surfaces of concrete complete all as specified and directed by Engr-in-charge
Use and waste of formwork Form work to soffits of suspended slab such as roof slab, floor slab etc. not exceeding 200mm thick rough finished surfaces concrete complete all as specified and directed by Engr-in-charge
Use and waste of formwork to chajjas etc including edges rough finished surfaces of concrete complete all as specified and directed by Engr-in-charge
S & F TMT steel deformed or twisted bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge
S & F TMTsteel deformed or twisted bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips. Gde Fe50 or FE 500d complete all as specified and directed by Engr-in-charge
M&L rendering 10 mm thick in cm 1:6 on fair faces of concrete surfaces and rendering is to be finished smooth and even without using extra cement complete all as specified and directed by Engr-in-charge
M&L for rendering on external surfaces of walls 15 mm thick, in two layers, comprising of under layer of 10mm thick rendering in CM 1:6 and final layer of 5 mm thick in CM 1:4 on the external surfaces finished even and smooth without using extra cement with WPC complete all as specified and directed by Engr-in-charge (Note:- WPC will be measered and paid saperately as supply only.)
M&L for rendering 5 mm thick in CM 1:3 on ceiling to be finished even & smooth without using extra cement complete all as specified and directed by Engr-in-charge
Supply only water proofing compound complete all as specified and directed by Engr-in-charge
Preparing new plastered surfaces and applying two coats of oil emulsion distemper over a coat of alkali resistant priming on wall surfaces complete all as specified and directed by Engr-in-charge
M & L for preparing new plastered surfaces and applying two coats of cement based paint over a coat of primer on wall surfaces complete all as specified and directed by Engr-in-charge
M&L for preparation of new ceiling surface and applying two coats of white wash complete all as specified and directed by Engr-in-charge
Filling under floor with moorum / red bajari in floor laid in layers not exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-charge
M&L for hardcore of broken stone or boulders of gauge not exc. 63mm and deposited spread and levelled in layers not exc. 15cm thick watered and rammed to a true surface complete all as specified and directed by Engr-in-charge
M&L for cement concrete sub base 75mm thick type C2, (1:3:6) (40mm graded aggregate) complete all as specified and directed by Engr-in-charge
M&L for providing 75mm thick plain cement concrete( 1:3:6) type C-2 using 40mm graded aggregate as in plinth protection complete all as specified and directed by Engr-in-charge
M&L Non skid Ceramic coloured Joint free tiles of 7-8mm thick (area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 15mm thick bedding layer of cement mortar (1:6) complete all as specified and directed by Engr-in-charge
M & L for Glazed ceramic tiles, coloured (light colour as approved), of size 450x300x7mm / 450X 350X 7mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 10mm thick rendering in cement mortar (1:3) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engr-in-chargeby Engr-in-charge.
S&F powder coated anodised Aluminium ventilator with fixed aluminium frame of size 65mmx40mmx1.98mm fixed in vertical position with aluminium vertical members and half portion to be provided with aluminum heavy duty adjustable loovers and 4mm thick pinhead glass and remaining portion to be louvered using 4mm thick pinhead glass and louvered portion covered with S.S wire cloth 0.36mm dia wire and average width of aperture 1.40mm incl F/h type frame work, rubber neoprene packing, anodised aluminium snap beading, screws, complete all as specified and directed by Engr-in-chargeby Engr-in-charge Note : Rates include all glazing/ S.S wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading grill loovers etc
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet/ wood grain reinforced with M.S. Square tube, suppling & fixing in opening as per specification , complete all as specified and directed by Engr-in-chargeby Engr-in-charge
M&L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-charge
S&F butt hinge, 100mm long, Extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directed by Engr-in-charge
S&F150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engr-in-charge
S&F Extruded aluminium alloy handles 150mm long, fabricated type, anodised, complete all as specified and as directed.
S&F 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil.
Removing excavated soil material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
S&F Bib Taps 15mm Bore, Chromium plated fancy type copper alloy,with crutch or butterfly screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs, complete all as specified and as directed.
S&F central hole wash hand basin mixer for mixing hot and cold water screwed down for iron pipe as per cat part No 6775 of Make - Prayag or techno commercially equivalent of make specified
S&F in Towel rail 450 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastic cleats complete all as specified and directed by Engr-in-charge
S&F Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement , grating and Union for discharge pipe including fixing supply pipe to flushing cistern, trap and waste pipe)
S&F Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-chargeby Engr-in-charge
S & F PVC connections 15mm size with PTMT nuts of length 450mm. complete all as specified and directed by Engr-in-charge
S&F stop valves, cast copper alloy, screwed down , high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions 15 mm bore (ISI Marked) complete all as specified and directed by Engr-in-charge
S&F 10 Ltr capacity PVC valveless symphonic action type flushing cistern, low level with inlet , ball valve, float all as specified including necessary flush pipe as directed complete all as specified and directed by Engr-in-charge
S&F Vitreous china (WHB) wash basin, white , flat back , size 550 x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engr-in-chargeby Engr-in-charge
S&F vitrous china down water closet pan (pedestal pattern), white or ivory with and including plastic seat cover , white/ivoery , closet pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, and fixed with and including 32 mm PVC flushing pipe complete all as specified and directed by Engr-in-charge
S&F soap dish, any type fixed to plugs with chormium plated brass screws complete all as specified and directed by Engr-in-charge
S&F Galvanised iron water tubes 15 mm bore (dia), Medium Grade' with all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and directed by Engr-in-charge
S&F Galvanised iron water tubes 20 mm bore (dia), Medium Grade' with all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and directed by Engr-in-charge
S&F rotational moulded polythelene water storeage tanks, 500ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I (ISI marked)
S&F Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fix complete all as specified and directed by Engr-in-charge
S&F 75 mm dia PVC (SWR) Nahani trap plain with grating incl jointing with solvent cement complete all as specified and directed by Engr-in-charge
S&F 75 mm dia PVC(SWR) pipes single stacked in any length laid in floor /wall complete all as specified and directed by Engr-in-charge
S&F 110 mm dia PVC(SWR) pipes single stacked in any length laid in floor / wall complete all as specified and directed by Engr-in-charge
S & F PVC (SWR) bends 110mm dia bore any radius with access door complete all as specified and directed by Engr-in-charge
S & F PVC (SWR) bends 75mm dia bore any radius with access door complete all as specified and directed by Engr-in-charge
S&F 75 mm dia PVC(SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed by Engr-in-charge
S & F Grating doom 100mm dia of PTMT(Minimum weight 25gms) complete all as specified and directed by Engr-in-charge
S & F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed by Engr-in-charge
M&L 32mm dia waste fittings for pipe, brass chromium plated for glazed ware sinks, basins, etc and fly-nuts, flange end bedded in red lead cement and otherend fixed complete all as specified and directed by Engr-in-charge
M & L pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall ,fixed with self tapping screws complete all as specified and directed by Engr-in-charge
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts mplete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with uitable arrangement.
S& F joist,channels,angles , Box section,flat irons, or T section fixed independently ,with out conecting plates etc including all necessary nut and bolts in Fe 410-w (Gde E-250) Quality A, complete all as specified and directed by Engr-in-charge
Excavating in post holes(or similar holes) each n exc 0.5 cum getting out and removing surplus soil to a distance n exc 50m and making good surfaces in soft/dense soil complete all as specified and directed by Engr-in-charge
S&F MS plates (plain or chequered) channel, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W-(Gde- E--250) quality-A complete all as specified and directed by Engr-in-charge
M & L for plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in embedding of posts, filling and mass concrete complete all as specified and directed by Engr-in-charge
Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 110 mm bore drain pipe complete all as specified and directed by Engr-in-charge
Cutting chases, pinning in , for concealed water tubing on brick walls, making good to facing where required and pointing in cement mortar 1:3, not exc 10 cm girth.
M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 110 mm dia SWG pipe complete all as specified and directed by Engr-in-charge
S&F for Rolled sections as in main and cross beams, hip and jack rafters; Purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates of Fe-410-W(Gde-E-250 quality-A) (framed) etc, complete all as specified and directed by Engr-in-charge
M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified and directed by Engr-in-charge
S&F glass corner self 300mm as per cat Part No BA-08 of Make - Prayag or equivalent as make specified
S&F toilet paper holder, fancy type fixed to plugs with chromium plated screws as per cat part NO BA-08 of Make - Prayag or equivalent as make specified
S&F health faucet (with 1.50mtr tube) fixed to Angular stop cock and complete wall hanging arrangement complete all as speciifed and dircted as per cat part No BEA 86 of Make : Prayag or equivalent as s specified and directed by Engr-in-charge
S & F jet spray 1.00m long flexible LDPE pipe fabricated and jointed with jet of 100mm long on one side and socket joint of 15mm dia. on other end, steel plate with adjustable hole and a groove to adjust the nozzle of jet, shall be chromium plated brass complete all as specified and directed by Engr-in-charge
S & Fixed Vitreous China Squatting Pan ‘ORISSA’ Pattern, size 580X440 mm White, with , 'P' or 'S' trap, front and back inlets ,integral foot rest, providing Joints between Flush Pipe and Socket of WC Pan including Flush Pipe of suitable size and connected Items, complete all as specified and as directed.
M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed by Engr-in-charge
M & L for preparation of New steel surfaces of any description, over 10cm in width or girth, not otherwise described and apply two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed by Engr-in-charge
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engr-in-charge
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked including sunk in anodized pressed steel box 1.60 mm thick, 60 mm deep for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-chargeby Engr-in-charge for following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
S & F for switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed by Engr-in-charge
S & F for socket outlet 2-in-1, 5 pin, 5 amp, 230 Volts complete all as specified and directed by Engr-in-charge
S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
M & L for clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified. Note :- Punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak of size 250 mm x 150 mm x 40 mm with minimum average breaking load 200 Kg as per IS 5820:1970, ISI marked all as specified and directed.
Supply and fixing GI Pipe light grade of size 25 mm dia with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable complete all as specified and directed by Engr-in-charge
Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade of size 2 core x 10 Sqmm, XLPE insulated and PVC shealhed, armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, passing through cable trench, pipes fixed on wall etc complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe light grade) and watering pipe 20mm bore GI pipe (medium grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), MS FUNNEL with wire mesh ,coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. incl taking down old earthing complete all as specified and directed by Engr-in-chargeby Engineer-in-Charge. Note :- GI earthing wire and protected pipe 15 mm dia of same size upto 7.5m shall deemed to be included into quoted rate
Supply, fixing & laying only GI tubing medium grade with both end threaded in any length including cutting threading connection in new or old position including provision of all type of GI fittings for laid in trenches/wall/ceiling/ floor/ all as specified and directed of following size :-
(a) 25 mm dia
(b) 20 mm dia
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of following sizes complete all as specified and directed by Engr-in-charge
(a) 25 mm dia
(b) 20 mm dia
M & L for cutting existing GI tubing 40/50 mm dia in position and screwing the pipe of both sides for insertion of tee reducer 50/40 x 25 mm dia for branch line etc to new water connection complete all as specified and directed by Engr-in-charge
M & L for Construction of brick masonry valves pits, of size 600 mm x 600 mm x 600 mm internal dimension complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete.
Ravi enterprise
S H CONSTRUCTION
RACON CONSTRUCTION
sanu enterprise
M/s Punnsons India
nasreenenterprise
Pooja Enterprise
suvidhiconstruction
Nirmal Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .