| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest Rate, Reasonable Rate | |
| 2 | L2₹4.4 L+₹12,542 (2.91%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹4.4 L+₹13,987 (3.25%)Rejected-Finance MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹4.6 L+₹33,128 (7.70%)Rejected-Finance SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹4.7 L+₹40,016 (9.30%)Rejected-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
24 Oct 2024, 6:00 pmClosed
AGE (I) Raiwala
AGE (I) Raiwala
REPAIR/ REPLACEMENT OF INTERNAL WIRING, SUBMAIN AND FITTING FIXTURE IN OTM ACCN AT RAIWALA MIL STN UNDER AGE (I) RAIWALA
2024_MES_674084_2
8946/E8
Open Tender
Civil Works
Works
150 days
AGE (I) Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Raiwala
₹20,000
Yes
17 Dec 2024
14 Oct 2024
26 Oct 2024
14 Oct 2024
24 Oct 2024
19 Oct 2024
14 Oct 2024 - 18 Oct 2024
Amount
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISImarked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per above item No.1 but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per above item No 1 but forOne 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per above item No.1 but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed .
All as per above item No.1 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed .
All as per above item No.1 above but for existing concealed conduit inside wall, ceiling etc(light, fan, call bell) complete all as specified and directed .
All as per above item No.1 but for existing concealed conduit inside wall, ceiling etc but for One 3pin/5pin 5/6 Amps socket out let on same board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per above item No.1 but for existing concealed conduit inside wall, ceiling etc but forOne 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per above item No.1 but for existing concealed conduit inside wall, ceiling etc but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed .
All as per Item No 1 above but for existing concealed conduit inside wall, ceiling etc with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed .
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian or equivalent make of L&T/ Cona
Supply and fix Modular Socket outlet, 6A - 3 pin, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz all as specified and directed by Engr-in-Charge.
Supply and fixing switch modular type single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge
Supply and fixing step socket type modular fan regulator 120/280 V 2 module with indicator, all as specified.
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals all as specified
Supply and fixing Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings all as specified and directed.
Supply and fix in repairs /replacement switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked all as specified and directed.
Supply and fix in repair/replacement switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way -ditto-.
Supply and fix in repairs/replacement, socket out let 3 pin 5/6 Amps flush type
Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC all as specified and directed of ISI marked
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
Suupply and fixing in repair step socket type fan regulator 120/280 V , ISI marked all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar. all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB VTPN 415V AC 4 way with 200 Amps rated bus bar. all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar all as specified and directed .
S& F MCCB 4 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA all as specified and directed .
Supply and fixing MCB SPN 32 Amp 240 V AC 10 KA 'C' Curve repturing capacity all as specified.
Supply and fixing MCB SP 5 to 10 Amp 'B' series 10 KA repturing capacity complete all as specified.
Supply and fixing MCB TPN/ FP 16-32 Amp, 415 V AC 'C' series 10 KA repturing capacity complete all as specified.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC all as specified.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit or more medium grade surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed .Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Material and labour for repair and replacement of existing rusted metal circuit box including hylam sheet and switch, sockets, regulators with new 1/ 2 way-6way modular type metal box with and incl decorative polycarbonate frame for housing modular switches, sockets, fan regulatrs etc including white cover plate complete and connect existing circuit wiring with new switches & testing complete all as specified and directed.Note:- 1 payment will be done for each module as per rates quoted by the contractor 2.switch /sockets /regulators will be paid seperately.
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box excluding conduit when in wiring in existing conduit, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc excluding conduit when in wiring in existing conduit complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified
M & L for remove unserviceable air termination rod and S & F Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specified and directed by Engr-in-Charge.
M & L for removing rusted terminal block and S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed by Engr-in-Charge.
M & L for removing broken strip and S & F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and connect with terminal block all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electorde of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.2 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth strip of size 25 x 4 mm earth lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 40 mm bore(medium grade) and connected to earth test point and including cement concrete pit in PCC (1:3;6) type C-!(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 300 x 300 x 50 mm thick with rain forced with 8 mm dia deformed bars both ways and one handle for lifing made with 10 mm dia mild steel bar,funrel, wire mesh 20 mm bore galvanised (medium grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate no 5 of MES Schedule Part I including taking out materials from existing on complete all as specified and directed.
janta tradrers (BID ID -3148999)
A ONE BUILDERS AND ENGINEERS (BID ID -3147434)
anant enterprises (BID ID -3145009)
TARUN ENGINEERING WORKS (BID ID -3147564)
neeraj electricals (BID ID -3149227)
S.K ASSOCIATE (BID ID -3145191)
satyabhama and co (BID ID -3145348)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .