Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.3 CrAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | ₹3.3 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹3.3 Cr+₹63,483 (0.19%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹3.3 Cr+₹63,483 (0.19%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹3.6 Cr+₹22.4 L (6.72%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹3.6 Cr+₹22.4 L (6.72%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹3.6 Cr+₹24.6 L (7.39%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹3.6 Cr+₹24.6 L (7.39%) | L-4 | Rejected-Finance Being L-4 |
| 5 | L-5₹3.6 Cr+₹26.4 L (7.94%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹3.6 Cr+₹26.4 L (7.94%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
26 Oct 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
PROVN OF FIRE DETECTION AND FIXED FIRE FIGHTING SYSTEM FOR CERTAIN BUILDINGS AT INAS 343 AT NAE PORBANDAR
2024_MES_675932_1
8914/E8
Open Tender
Civil Works
Lump-sum
365 days
Porbandar
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (NAVY) PORBANDAR
₹4.3 L
Yes
9 Dec 2024
21 Sept 2024
29 Oct 2024
21 Sept 2024
26 Oct 2024
19 Oct 2024
Amount
SCH 'A' PART-I : "(BUILDING PUMP FOR HOUSE AND UG SUMP)" brought forwarded from Serial Page No. 23 (R)
SCH 'A' PART-II : "SITE CLEARANCE" Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 24
SCH 'A' PART-III : "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 25 (R)
SCH 'A' PART-IV : "INTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 28 (R)
SCH 'A' PART-V: "LIGHTNING PROTECTION" Total of Schedule 'A' Part-V brought forwarded from Serial Page No. 29
SCH 'A' PART-VI : "FIRE FIGHTING" Total of Schedule 'A' Part-VI brought forwarded from Serial Page No. 40 (R)
SCH 'A' PART-VII "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No. 41
SCH 'A' PART-VIII "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No 42
SCH 'A' PART-IX"MISC WORKS"
"SOIL INVESTIGATION"
Drilling of 100mm bore holes upto 15m deep for UG sump in all type of strata collecting disturbed and undistrubed sample and performing SPT Test at 1.00m interval lab testing including traixial test direct shear teat liquid limit, plastic limt, liquefaction of soil, sweeling index and sweeling preassure (incase of black cotton soil). Location : Naval Air Force Porbandar
Drilling of 100mm bore holes upto 10m deep for UG sump in all type of strata collecting disturbed and undistrubed sample and performing SPT Teast at 1.00m interval lab testing including traixial test direct shear teat liquid limit, plastic limt, liquefaction of soil, sweeling index and sweeling pressure (in case of black cotton soil). Location : Naval Air Force Porbandar Note for item No, 10.01 & 10.02 : Soil investigation report to be recommended on the following parametres:- 1. SBC of all bore holes, minimum at three depth i.e. 2m 2.5m and 5m 2. SBC to be worked out for following size of footings:- (a) 1.50 x 1.50m (b) 1.50 x 2.00m (c) 2.00 x 2.50m (d) 2.00 x 3.00m 3. Submission of photographic record of geo-exploration 4. Possibility of liquidation of soil in case of saturated or partially saturated loose / uncompacted sany soils. 4. Bearing capacity calculation 5. Recommendation of filling under floors 6. Sweeling index and sweelling pressure in respect of black cotton soil
"FIRE FIGHTING"
Supply and fix Foot Valve 200mm dia conforming to IS 4038
All as per item No. 11.01 above but 100mm dia
Supply and fix Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of 10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia.
Supply, Installation,Testing & commissioning of MECHANICAL FOAM type fire extinguisher of 9 Ltrs confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Trolley Mounted MECHANICAL FOAM type fire extinguisher of 50 Ltrs Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Trolley Mounted DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 25 Kg confirm to IS : 16087, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of trolly mounted Carbon Dioxide (Co2) type fire extinguisher of 22.5 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 9 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply and installation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & Showel etc, complete.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1100 Volts grade 3 Core 1.5 sqmm
S & F escape light route indicator with in built battery back up of 3 hrs including provision of 5 Amps independent socket point wiring of nominal area 1.5 Sqmm PVC insulated & PVC unsheathed ,multi stranded copper conductor cable FRLSH and in including casing caping /pvc conduit 20 mm dia medium grade ISI marked , with modular 5 amps socket and 5 Amps modular switch , cover plate with PVC box all as specified & directed by Engr-In-Charge
"EXTERNAL WATER SUPPLY"
Geographical Survey of ground water from any approved hydrologist agency to explore the ground water potential of the area & submitting the technical report to departmment giving recommendation on feasibility of tube well at particular location complete all as specified & directed.
Trial bore of 200 mm dia upto 200meter depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc.
Development of trial bore by reaming in from 200 mm to 350mm upto 60mtrs from ground level including required PVC casing pipe of size 200mm dia and thickness 8mm ,reducer, bail plug, well cap, clamps,electric logging, sample strata box, pea garvel etc. complete all as specified & as directed.
Supply and fix PVC slotted pipe of 200 mm dia 8mm thick in lieu of casing pipe of 200 mm dia complete all as specified & as directed.
Supply & fix column pipe of size 80mm dia galvanized, medium class including fittings & all flange joints complete all as specified & as directed.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water complete all as specified & as directed.
Yield test for the bore well by continuously pumping for 16 hours to determine safe pumping yield complete all as specified & as directed.
Supply , install , commissioing of Submersible pump, electric driven ,5WHP 415 V suitable for 200/250 mm dia bore well inclusive ofsuitable size pressure gauge , 60. meter long submerssible cable , electric panel with suitable size MCCB ,starter , Phase indicating lamp , Ammeter , Voltmeter set & other accessories complete all as specified & as directed.
Testing of water samples from bore well at government recognized institute for portability & chemical analysis complete all as specified and as directed.
"EXTERNAL ELECTRIC SUPPLY"
Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 110/95 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.
Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 90 /76 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.
shree chamunda enterprise (BID ID -3148454)
Shree Ayyappa Engineering (BID ID -3149926)
cooltech engineering services (BID ID -3149964)
sapana enterprises (BID ID -3149690)
shakti engineering and electrical works (BID ID -3150443)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .