Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 CrAccepted-Finance | ₹27.1 Cr | L1 | Accepted-Finance OK |
| 2 | L2₹27.1 CrAccepted-Finance 1 513 VIDHYADHAR NAGAR JAIPUR 302039 RAJASTHAN | JAIPUR | RAJASTHAN | 302039 | ₹27.1 Cr | L2 | Accepted-Finance OK |
| 3 | Not Admitted-Fee | - | - | Not Admitted-Fee Fee not received |
| 4 | Not Admitted-PreQual/Technical N 29 ADINATH NAGAR OPP WORLD TRADE PARK JAI JAWAN COLONY III MALVIYA NAGAR JAIPUR 302034 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302034 | - | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹28.1 Cr
EMD Value
₹56.2 L
Closing Date
12 Apr 2023, 6:00 pmClosed
EE M and H Kota
Near Ucco Bank Kota Junction Kota
Construction of 150 Bedded District Hospital at Kota, Distt. Kota (Including Internal Electrification work) (PIP 2021-22)
2023_MEDIC_326000_1
C.E. Jaipur NIT No. 35/2022-23
Open Tender
Civil Works
720 days
Kota
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
EE M and H Kota
₹56.2 L
Yes
16 May 2023
23 Mar 2023
13 Apr 2023
23 Mar 2023
12 Apr 2023
23 Mar 2023
Amount
Part "B" Non BSR Item :Supply of Painted/ Powder coated galvanized steel Flush Fire doors of Pacific make of 2 hrs. Fire rating and tested in accordance with IS 3614 Part 2 & BS 476 Part 22 as per prototype tested and certified at CBRI Roorkee or equivalent laboratory. Door frames to be double rebate profile of 143 x 57mm manufactured from 1.6mm galvanized steel sheet, profile to have bending radius of 1.4 mm supplied in assembled form ready to install at site. Door Shutter in 46mm +2 mm thick manufactured from 1.2mm galvanized steel sheets, lock seam jointed at stile edges to form a double skin fully flush shell. Infilled honeycomb insulation material to be provided for structural rigidity & additional reinforcements & sound Insulation, The internal construction of the door should be appropriate for all hardware fixtures (SS Ball BearingHinges-4"x3"X3mmGeze,Door Closer, Dead LockWith 70mm EPC,Handle-300X19mm, Vision Panel,Flush Bolt etc.) as required, vision panel grooves wherever applicable shall be provided as per recommendations with beading and screw. (Hardwares to be paid seperately as per your requirement.) Size: 1800 x 2100mm- Double Leaf
Desisigning Development providing and fixing of Acrylic Sandwich way signages in different building. The various different sized signages like building directory,facilties, room nos. etc. are made out of A grade Acast or equivalent brands 5mm thick transparent acrylic sheet at back and 3mm thick on front side. The eco-print on 3M IJ 15-10 monomeric calandared Vinyl film sheet of approved colour pattern and shade is sandwich between two acrylic sheets with required number and size of stainless steel studs and fittings, The outer edges are tapered and finished smooth. The developer has to design the signages for different buildings as per requirement of the client and got the design and sample approved from competent authority before going in to actual execution at site. Basic dataa for clients requirement would be provided by the department.
This should be a hermetically sealed, single sliding door of 2.1 (H)X 1.8 m(W), The controller should be capable of being operated by elbow switches/foot switches as well as touch less sensor.The track should be of Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the Aluminium track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. The door material should be of HPL Color should match the interior and care should be taken to make the leaf strong and light weight. One should be able to open and close the door effortlessly incase of failure of automatic mechanism. Door opening handle should be strong and sturdy. Material should be of SS (gloss finish). Should be provided with high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100Pa.The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be 60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 52 mm nearby. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. SDA04 automation with battery backup PMDC motor. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed. Door movement should have minimum noise. The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.
Non BSR Item Electrical Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phases input three phase output. Online double conversion VFI-SS-111 technology, with sinusoidal wave form, architecture (standalone of distributed parallel up to 8 units), having input characteristics i.e. input voltage (380v, 400v, 415v, 3Ph+N+PE), input frequency (45 -65 Hz), input voltage range (Ph - Ph) : (half load 208v -467v/ full load 312v - 467v), total harmonic distortion of input current < 3% (at full linear load), compatibility with diesel generators configurable for synchronization between the input and output frequencies even for high frequency variations, input power factor > 0.99, having output characteristics i.e. output voltage (380v, 400v, 415v, 3Ph+N (adjustable from front panel), efficiency up to 96%, efficiency in ECO mode up to 98.5%, output frequency (nominal) 50 /60 Hz 0.01% free run (adjustable from front panel), crest factor 3 : 1, total harmonic distortion of output voltage < 2 % (at full linear load), output power factor 0.9, output voltage tolerance ± 1%, built in automatic and maintenance bypass, inbuilt isolation transformer, battery type (VRLA - AGM maintenance free). Communication & management i.e. 30 KVA (3 phase input & 3 phase output) For 30 minute backup, min. 24000 VAH
Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications. EPABX system consists of 64 nos. extensions, 16 nos of junction & upto 128 nos. of expandable eport, with one operating console, 3 Amp max. current
Supply, installation, testing and commissioning of telephone instrument as approved by architect (Siemens/ Panasonic/ Tata/ BPL)
Bidder Name
Amount
MS ANKIT CONSTRUCTION(GSTN-08ABLFA3541Q1ZY)
LNA Infraprojects Pvt. Limited(GSTN-08AADCL1585B1ZQ)
LNA Infraprojects Pvt. Limited
LNA Infraprojects Pvt. Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid