Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.7 L+₹3.7 L (16.2%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹27.7 L+₹4.7 L (20.4%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹28.2 L+₹5.2 L (22.8%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹60,380
Closing Date
17 Sept 2020, 6:00 pmClosed
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT- 133001
PROVN OF LED SECURITY LIGHTS WITH POLES AND CONNECTED ITEMS INCLUDING OTHER MISC SANCTIONED REVENUE AND MINOR WORKS FOR ACs DESERT COOLERS WATER COOLERS REFRIGERATORS AND DEEP FREEZERS UNDER GE UTILITY AMBALA CANTT
2020_MES_360619_2
GE(U)/AMB-41/2020-21
Open Tender
Civil Works
Item Rate
180 days
AMBALA CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹60,380
Yes
9 Feb 2021
28 Aug 2020
19 Sept 2020
28 Aug 2020
17 Sept 2020
4 Sept 2020
28 Aug 2020 - 3 Sept 2020
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete al las specified and directed by Engineer-in-Charge.
Description all as per Item Ser No 1.00 above but exceeding 1.5 mtr deep but not exc 3.0mtr deep.
M & L sand cushioning for cable with river washed clean dry sharp sand and punning to provide required cover as per SSR Part I complete all as specified and as directed by Engineer-in-Charge. Note- Punned thickness shall be measured and paid to the contractor.
Supply and laying old size bricks common burnt clay sub class 'B' for cable protection to provide required cover complete all as specified and as directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 (using 40mm graded aggregate, mechanically crushed stone) for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, coping, stay pits etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as specified and directed by Engineer-in-Charge.
Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces incl providing of two coats of black and white strips with synthetic enamel paint 30 cm high each alternate strip 1.5 mtr above the coping of pole starting with black strip and with black bituminous paint for embedded portion of pole all as specified and directed at site. Note: Earth work and PCC shall be measured and paid for separately. (ii) Description and matter as specified and directed by Engr-in-Charge will be printed on each pole without any extra cost.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 2.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks , removing, returning filling will be paid separately. (ii) Cost of Aluminium thimbles/lugs, laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Description all as per Item Ser No. 10 here in before but for 35 Sqmm 3.5 core
Supply & fixing factory made street light terminal box made out of fibre material complete with TPN ,aluminium bus bar including one No MCB SP 6 Amps 240 volts mounted on DIN rail including ,MS clamp made out of 20x4mm flat iron ,street light terminal box to be mounted on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge.
M&L new street light bracket made out of GI pipe light grade 40mm bore suitable for LED street light approx length not less than 120cm bent to shape including new clamps made of MS flat of size 30x4 mm thick including cutting, welding drilling holes, nut, bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
Supply & fixing GI tubing light grade 40 mm bore on poles, under floors, road crossing etc all as reqd at site and as directed by Eng-in-Charge
Supply and fixing or passing through pipe, 1100 volts grade heavy duty , PVC insulated round 3 core 2.5 sqmm copper cable including electrical connection complete all as specified and directed by Engr-in-Charge. Note: PVC pipe will be measured and paid separately under relevent items.
Supply and fixing rigid non-metallic PVC conduit of dia 25 mm , wall thickness 2mm inclusive of all tees, bends,elbows, reducers, bell mouth tube ends including MS clamps made out of 25x4mm MS flat to secure the PVC pipe with steel tubular pole/PCC pole at 2 to 3 places complete with bolts,nuts and washers etc all as specified and as directed..
Supply and fixing LED street light fitting of capacity 90 watt suitable for working on 230 volts AC supply ENDURA CITYLINER NEO/NEO N energy saving and environment friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartmentwith IP66 protecrtion and impect resistance of IK07 with 10 KV Built in surge protection device and suitable for fixing on 40 mm dia street light bracket complete all as directed by Engineer-in-charge.
Material & labour new earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge.
M & L cutting wall/road/PCC/Hard standing /Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, including making surface finished complete all as specified and as directed.
S & F of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Neutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 2EC5kW3P-VMS /Schneider/Havells/Legrand Make (i)Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof,FR rade) (v) Circuit wiring-Polycab/Finolex, Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years. (iii) Test certificate and warranty cirtificate must be provided by contractor. (iv) Cost of marking description on the box is incl quoted rates.
Supply & installation of desert cooler of size 660x660x825mm (height) with outer body made out of PGI (Plain Galvanised iron) sheet not less than 0.90mm thickness for fixed part, thickness of PGI sheet for shutter not less than 0.70mm thick, front grill made out of PGI sheet with minimum weight 2.80Kgs or plastic grill as approved. Electric driven copper wounded fan motor 500mm sweep, three speed (high /medium/low) with metalic blade duly painted with synthetic enamel anticorrosive oven cured paint fitted to body, 1400RPM, 230 Volt, 50Hz and submersible pump for required flow of water (single phase) having nominal air flow capacity 4000cum per hour, wood wool pad shall be of proper thickness as approved complete all as specified and as directed.
M&L MS work such as angle iron flat iron (40mmx40mmx5mm) for desert cooler stand in any shape and size complete welding and cutting as directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note: Size of angle iron, flat iron will be as per the direction of Engineer-in-Charge.
M&L point wiring for 3 pin socket outlet 15 Amp independent with 2.5 sqmm copper stranded conductor PVC insulated and unsheathed cable ISI marked (FRLS) and drawing in and including non metallic medium grade not less then 19mm dia PVC conduit (heavy duty) ISI marked on surface of wall/ceiling with and including all conduit fitting clamps gutties, etc for one light point control by one switch including in MS sunken box or pressed steel terminal boxes with provision of new 2.8 mm thick plastic lamination sheet and housing the switches with brass screw and washers and PVC insulated continues earth wire of size 2.5 Sqmm (FRLS) of green colour to earth metal parts of fitting as specified and directed by Engr-in-Charge.
M&L point wiring for 3 pin socket outlet 15 Amp independent with 4.00 sqmm copper stranded conductor PVC insulated and unsheathed cable ISI marked (FRLS) and drawing in and including non metallic medium grade not less then 19mm dia PVC conduit (heavy duty) ISI marked on surface of wall/ceiling with and including all conduit fitting clamps gutties, etc for one light point control by one switch including in MS sunken box or pressed steel terminal boxes with provision of new 2.8 mm thick plastic lamination sheet and housing the switches with brass screw and washers and PVC insulated continues earth wire of size 4.0 Sqmm (FRLS) of green colour to earth metal parts of fitting as specified and directed by Engr-in-Charge.
S&F socket out let 3 pin, 5/15 Amps flush type ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way 15 Amp ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% and of capacity 5.0 KVA complete all as specified and directed by Engr-in-Charge.
Supply and installation air cooled split unit air conditioner hot and cold, digital inverter driven with cordless remote control with BEE 5 star rating of capacity 2.0 TR complete all as specified and directed.
Supply and installation air cooled split unit air conditioner hot and cold, digital inverter driven with cordless remote control with BEE 5 star rating of capacity 1.5 TR complete all as specified and directed.
M&L single pole and neutral encosure with 2 pin and earth plug and socket complete with one single pole MCB SP 20 Amps ISI marked complete all as directed.
M&L wall stand for 2.0 TR capacity AC ready made out of MS angle of suitable size with stand load satisfactory complete all as directed
Supply and installation water cooler electric driven single phase 240 Volt, 50 Hz having Approx storage capacity of 120 Ltrs and nominal cooling capacity of 60 Ltrs per hour complete all as specified and directed by Engr-in-Charge.
Supply and installation water cooler electric driven single phase 240 Volt, 50 Hz having Approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs per hour complete all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% and of capacity 0.5 KVA complete all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% and of capacity 2.0 KVA complete all as specified and directed by Engr-in-Charge.
Supply and installation of refrigerator single phase, capacity 360 Liters double door BEE 5 star rated complete all as specified and directed by Engr-in-Charge.
Supply and installation of metal top Deep freezer single phase 240 volt, 50 Hz of cap 400 Ltrs complete all as specified and directed by Engr-in-Charge.
Supply and installation of hard top Deep freezer single phase 240 volt, 50 Hz of cap 320 Ltrs complete all as specified and directed by Engr-in-Charge.
Gupta Enterprises
UNITED ENGINEERING CORPORATION
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .