Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 CrAccepted-AOC 1 50 MANGALAM RIICO INDUSTRIAL AREA KANAKPURA JAIPUR RAJASTHAN | JAIPUR | RAJASTHAN | ₹6.5 Cr Quoted ₹7.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹7.1 Cr+₹12.0 L (1.70%)Rejected-Finance | ₹7.1 Cr+₹12.0 L (1.70%) | L2 | Rejected-Finance Above Rates |
| 3 | Not Admitted-Fee/PreQual/Technical 2 CORRIGENDUM ADDENDUM 01 DATED 11 01 2024 3 YOUR TENDER SUBMITTED ON 15 01 2024 ON E TENDER WEBSITE 4 CORRIGENDUM ADDENDUM 02 DATED 06 02 2024 5 YOUR PRICE BID OPENED ON 06 02 2024 ON E TENDER WEBSITE | - | - | Not Admitted-Fee/PreQual/Technical Others-Tender rate validity on Rs. 100/- Stamp paper with Re.1/- duly signed and Pending Litigation History on Rs. 100/- Stamp paper are not submitted in hard copy at this office. |
Tender Value
Refer Docs
EMD Value
₹13 L
Closing Date
6 Dec 2021, 5:00 pmClosed
Superintending Engineer
Office of The Superintending Engineer, 11th E/M Circle, PWD, 107, Nehru Colony, Phase-II (Dharampur), Dehradun
Supply, Installation, Testing and Commissioning of Electric Panel and Cables under C.S.R. Head of Reconstruction and Restoration of Shri Kedarnath Dham and Surrounding Areas
2021_pwd_38299_1
3753/7CB(I)-11/2021
Open Tender
Electrical Works
Item Rate
270 days
Kedarnath town
Please refer Tender Documents
2 documents required · 2 mandatory
₹5,900
Executive Engineer, E/M Division, PWD, Gopeshwar
₹13 L
Dehradun
10 Aug 2022
11 Nov 2021
7 Dec 2021
11 Nov 2021
6 Dec 2021
11 Nov 2021
11 Nov 2021 - 26 Nov 2021
26 Nov 2021
Amount
All motor feeders MCCBs shall be of motor duty. Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 54 for all Indoor panel. IP 65 and double door for all outdoor panel. All MCCB’s shall be provided with operating mechanism for door interlock. All measuring instruments (Meters) shall be of digital electronic with LED of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing MCCBs shall be placed on middle portion of the vertical in single tier formation. Aprooved Makes-L&T/ABB/schnider/Legrant/SIEMENS
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel 3A Having 1000 Amp 50 kA FP ACB (01 No) Incomer.Out Going 160 Amp FP 36KA MCCB (07No) ,125 Amp FP 36KA MCCB (02 No), & 32 Amp FP 36KA MCCB (01No) (IOCL)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel 3B Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (04No),160 Amp FP 36KA MCCB (04No), (IOCL)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel 3C Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (04 No),200 Amp FP 36KA MCCB (01No) & 160 Amp FP 36KA MCCB (01No), 100 Amp FP 36KA MCCB (02No) 40 Amp FP 36KA MCCB (04No) (IOCL)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel 4A Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (02No),200 Amp FP 36KA MCCB (02No) ,160 Amp FP 36KA MCCB (03No),100 Amp FP 36KA MCCB (01No) ,63 Amp FP 36KA MCCB (02No),40 Amp FP 36KA MCCB (02No)& 32 Amp FP 36KA MCCB (01No) (IOCL)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel 4B Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (05 No),160 Amp FP 36KA MCCB (01 No), 63 Amp FP 36KA MCCB (03No),& 25 Amp FP 36KA MCCB (01No) (IOCL)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel 4C Having 200 Amp 36 kA FP MCCB (01 No) Incomer.Out Going 125 Amp FP 36KA MCCB (02 No),63 Amp FP 36kA MCCB (05No) (IOCL)
Supply, Installation, testing and commissioning of IP 65 rated Ext. Ltg. Panel 3 Having Incomer 32 Amp 16 KA FP MCB (01No) 32 Amp heavy duty contactor (02No) Out Going 16 Amp FP 10KA MCB (11No) 16 Amp SP 10KA MCB (33No) 25 Amp FP 10KA MCB (7No) 25 Amp DP 10KA MCB (2No) with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. (IOCL)
Supply, Installation, testing and commissioning of IP 65 rated Ext. Ltg. Panel 4 Having Incomer 32 Amp 16 KA FP MCB (01No) 32 Amp heavy duty contactor (02No) Out Going 16 Amp FP 10KA MCB (19No) 16 Amp SP 10KA MCB (57No) 25 Amp FP 10KA MCB (7No) 25 Amp DP 10KA MCB (2No) with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. (IOCL)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel ME-A Having 630Amp 36 KA FP MCCB (01 No) Incomer .Out Going 630 Amp FP 36KA MCCB (01No), 40 Amp FP MCCB (01 Nos),200Amp FP MCCB (01 Nos) (ONGC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel ME-B Having 630Amp 36 KA FP MCCB (01 No) Incomer.Out Going 200 Amp FP 36KA MCCB (02 No),125 Amp FP 36KA MCCB (02No) (ONGC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel ME-C Having 630Amp 36 KA FP MCCB (01 No) Incomer.Out Going 200 Amp FP 36KA MCCB (03 No),125 Amp FP 36KA MCCB (01No) & 40 Amp FP 36KA MCCB (01No) (ONGC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel ME-D Having 630Amp 36 KA FP MCCB (01 No) Incomer.Out Going 200 Amp FP 36KA MCCB (03 No),125 Amp FP 36KA MCCB (02No) & 40 Amp FP 36KA MCCB (01No) (ONGC)
Supply, Installation, testing and commissioning of IP 65 rated Ext. Ltg. Panel ME-1A Having Incomer 40 Amp 16 KA FP MCB (01No) 40 Amp heavy duty contactor (02No) Out Going 16 Amp FP 10KA MCB (11No) 16 Amp SP 10KA MCB (33No) 25 Amp FP 10KA MCB (7No) 25 Amp DP 10KA MCB (2No) with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. (ONGC)
Supply, Installation, testing and commissioning of IP 65 rated Ext. Ltg. Panel ME-1C Having Incomer 40 Amp 16 KA FP MCB (01No) 40 Amp heavy duty contactor (02No) Out Going 16 Amp FP 10KA MCB (11No) 16 Amp SP 10KA MCB (33No) 25 Amp FP 10KA MCB (7No) 25 Amp DP 10KA MCB (2No) with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. (ONGC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Pane-2A Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (02 No), 200 Amp FP 36KA MCCB (03No) , 160 Amp FP 36KA MCCB (03No) & 32 Amp FP 36KA MCCB (01N) (PFC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel-2B Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 315 Amp FP 36KA MCCB (01No), 250 Amp FP 36KA MCCB (01No), 200 Amp FP 36KA MCCB (03No),160 Amp FP 36KA MCCB (03No) , (PFC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel-2C Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 315 Amp FP 36KA MCCB (02No), 250 Amp FP 36KA MCCB (02No), 200 Amp FP 36KA MCCB (04No), (PFC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel-2D Having 1000 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (01No),200 Amp FP 36KA MCCB (02No) , 160 Amp FP 36KA MCCB (03No), 125 Amp FP 36KA MCCB (02No ) (PFC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel-2E Having 630 Amp 36 KA FP MCCB (01 No) Incomer.Out Going 200 Amp FP 36KA MCCB (03No),160 Amp FP 36KA MCCB (01No) , 100 Amp FP 36KA MCCB (01No)(PFC)
Supply, Installation, testing and commissioning of IP 65 rated EX. LTG. Panel-2 Having Incomer 32 Amp 16 KA FP MCB (01No) 32 Amp heavy duty contactor (02No) Out Going 16 Amp FP 10KA MCB (11No) 16 Amp SP 10KA MCB (33No) 25 Amp FP 10KA MCB (7No) 25 Amp DP 10KA MCB (2No) with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. (PFC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Pane-1A Having 1250 Amp 50 kA FP ACB (01 No) Incomer.Out Going 250 Amp FP 36KA MCCB (03 No),200 Amp FP 36KA MCCB (01No) & 160 Amp FP 36KA MCCB (03No), 125 Amp FP 36KA MCCB (01No) 40 Amp FP 36KA MCCB (01No) (REC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel-1B Having 1000 Amp 50 kA FP ACB (01 No) Incomer.Out Going 315 Amp FP 36KA MCCB (01No), 250 Amp FP 36KA MCCB (02No) , 200 Amp FP 36KA MCCB (01No) 160 Amp FP 36KA MCCB (02No) & 125 Amp FP 36KA MCCB (01No) , (REC)
Supply, Installation, testing and commissioning of IP 66 rated Electrical Panel-1C Having 1000 Amp 50 kA FP ACB (01 No) Incomer. Outgoing 250 Amp FP 36KA MCCB (02No) , 200 Amp FP 36KA MCCB (02No), 160 Amp FP 36KA MCCB (03No), 100 Amp FP 36KA MCCB (01No) , 40 Amp FP 36KA MCCB (01No) & 32 Amp FP 36KA MCCB (01No) (REC)
Supply, Installation, testing and commissioning of IP 65 rated EX. LTG. Panel-1 Having Incomer 40 Amp 16 KA FP MCB (01No) 40 Amp heavy duty contactor (02No) Out Going 16 Amp FP 10KA MCB (11No) 16 Amp SP 10KA MCB (33No) 25 Amp FP 10KA MCB (7No) 25 Amp DP 10KA MCB (2No) with dual digital timer for switching on off lights according to rising/setting of the Sun with combination function for creating switching program. (REC)
DISTRIBUTION BOARDS
Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But .without MCB/RCCB/Isolator) - 8way, Double door (IP43, IK09)
Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12way, Double door (IP43, IK09)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supply, installation, testing and commissioning 'B' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO) (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40A. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
MV CABLES Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95sq. mm and upto 185 sq. mm
Above 185 sq. mm
Supply of Aluminnum/Cu Conductor PVC insulated Armored,served,sheathed cable of 1.1 KV grade at Depth Of 750mm Below Ground level Over A cushion of 75 mm Thick Sand Around and Protected with Burnt Bricks on side and own Top as Directed by Engineer Incharge Complete in all respect. Approved Makes- FINOLEX / POLYCAB / KEI/Havells
3.5C x 630 Sq.mm. Aluminum XLPE armored cable
3.5C x 400Sq.mm. Aluminum XLPE armored cable
3.5C x 300 Sq.mm. Aluminum XLPE armored cable
3.5C x 240 Sq.mm. Aluminum XLPE armored cable
3.5C x 185 Sq.mm. Aluminum XLPE armored cable
3.5C x 150 Sq.mm. Aluminum XLPE armored cable
3.5C x 120Sq.mm. Aluminum XLPE armored cable
3.5C x 95 Sq.mm. Aluminum XLPE armored cable
3.5C x 70 Sq.mm. Aluminum XLPE armored cable
3.5C x 50 Sq.mm. Aluminum XLPE armored cable
3.5C x 35 Sq.mm. Aluminum XLPE armored cable
3.5C x 25Sq.mm. Aluminum XLPE armored cable
4C x 6 Sq.mm. Aluminum XLPE armored cable
4C x 16 Sq.mm. CU XLPE armored cable
4C x 10 Sq.mm. CU XLPE armored cable
4C x 6 Sq.mm. CU XLPE armored cable
3C x 10 Sq.mm. CU XLPE armored cable
3C x 6 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
3C x 2.5 Sq.mm. CU XLPE armored cable
3C x 6 Sq.mm. Aluminum XLPE armored cable
CABLE TERMINATION Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland.
3.5C x 630 Sq.mm. Aluminum XLPE armored cable
3.5C x 400Sq.mm. Aluminum XLPE armored cable
3.5C x 300 Sq.mm. Aluminum XLPE armored cable
3.5C x 240 Sq.mm. Aluminum XLPE armored cable
3.5C x 185 Sq.mm. Aluminum XLPE armored cable
3.5C x 150 Sq.mm. Aluminum XLPE armored cable
3.5C x 120Sq.mm. Aluminum XLPE armored cable
3.5C x 95 Sq.mm. Aluminum XLPE armored cable
3.5C x 70 Sq.mm. Aluminum XLPE armored cable
3.5C x 50 Sq.mm. Aluminum XLPE armored cable
3.5C x 35 Sq.mm. Aluminum XLPE armored cable
3.5C x 25Sq.mm. Aluminum XLPE armored cable
4C x 6 Sq.mm. Aluminum XLPE armored cable
4C x 16 Sq.mm. CU XLPE armored cable
4C x 10 Sq.mm. CU XLPE armored cable
4C x 6 Sq.mm. CU XLPE armored cable
3C x 10 Sq.mm. CU XLPE armored cable
3C x 6 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
3C x 2.5 Sq.mm. CU XLPE armored cable
3C x 6 Sq.mm. Aluminum XLPE armored cable
POINT WIRING Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FR PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N)+1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N)+1 x 1.5 mm²(E) Power circuit (for heater and geyser) =2x4.0 sqmm (P+N)+1x4 sqmm(E) Cost of MCB shall not be considered in point rate. Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as required- Group A
light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, onnection, painting etc. as required. (For light plugs to be used in non residential buildings).
power plug point modular type accessories: Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and flxing of Brass batten/angle holder including connection etc. as required.
CONDUIT & OTHER Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Approved Makes- Polycab /Finolex/AKG
EARTHING
G.I earth plate elctrode: Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required
S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
LIGHT FIXTURES
Supply, Installation, assembling, connection, testing & commissioning of 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.Approved Make-Philips /Crompton/Orient/Havells
Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Surface mounted LED Down light fixtures equivalent to complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. Approved Make-Philips /Crompton/Orient/ Havells
SITC of exhuast fan (450mm) Approved Make Orient/Crompton/Bajaj
DWC PIPES Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. Aproved Makes-Jindal/Crown/Polyplast
120 mm dia (OD-120 mm & ID-103 mm nominal)
315mm dia (OD-120 mm & ID-103 mm nominal)
CURRENT INFRAPROJECTS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .