Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹39.6 L+₹34,070 (0.87%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹39.7 L+₹45,005.55 (1.15%)Rejected-Finance 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | COCHIN | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹42.6 L+₹3.4 L (8.68%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹43.8 L+₹4.6 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
REPAIRS TO TILES, PCC FLOOR, WALL, ROOF, ROOF SHEET, REPAIRS TO SUNKEN FLOOR, PLASTERING, PLINTH PROTECTION ETC, UNDER AGE B/R ALWAYE.
2021_MES_445989_1
8805/E8
Open Tender
Civil Works
Item Rate
330 days
ALWAYE.
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹90,000
Yes
29 Sept 2021
27 May 2021
17 Jul 2021
27 May 2021
15 Jul 2021
13 Jun 2021
27 May 2021 - 12 Jun 2021
60 days
Amount
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness below or above ground level complete all as specified and directed.
Material & Labour for 75 mm thick cement concrete 1:3:6, type C2 (40 mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and as directed.
Material & Labour for non-skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors over 15mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
Material & Labour for non-skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors over 15mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
All as per Serial item No 5 but as in skirting on 10mm thick backing coat in CM 1:3.
Material & Labour for non-skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over 15mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
All as per Serial item No 7 but as in skirting on 10mm thick backing coat in CM 1:3.
Material & Labour for glazed coloured ceramic tiles of size 300x200x7mm thick in vertical surface over 10mm thick backing coat in cement mortar (1:3) as back coat, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
All as per Serial item No 9 but size of tile 450x300x7mm thick.
Material & Labour for Kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment match the shade of the slab including rubbing and polishing complete all as specified and as directed.
All as per item No 11 but in skirting dado over 10mm thick as backing coat in CM 1:3.
Dismantling plain or corrugated steel sheet/MS sheet of any gauge thickness and in any position complete all as directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheet in roof covering complete all as directed.
Dismantling of Mangalore pattern or similar tiles in roofing complete all as directed.
Dismantling of ceiling boards (Fibre, pulp, insulation etc) of any thickness/description, including cover fillets fixed in any position with screws complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in any section, in any position and in any description of work complete all as directed.
Dismantling of fillets, rails, posts, rafters, purlins etc, under 40 sq. cm in section complete all as directed.
Supply & Fixing pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550MPa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
All as per Serial item No. 19 but for galvalume aluminium zinc coating GI based plain steel sheet 0.50mm.
Material & Labour for 0.63mm thick CGI sheet as in roof coverings with normal zinc coating of 275 g/Sqm with two corrugation side lap (and not less than 150mm end laps) fixed with galvanized crank 'J' or 'L' hook bolts and nuts not less than 8mm dia including embossed galvanized washers and bituminous washers complete all as specified and directed.
All as per Serial item No 21 but for except sheet
Material & Labour for 0.80mm thick plain GI Sheeting as in ridge, hips, and valleys gutters (length and girth as fixed) with 'J' or 'L' hooks and bitumen washers etc complete all as specified and as directed.
Material & Labour for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed.
All as per Serial item No 24 but except tiles.
Material & Labour for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
Supply & Fix 6mm thick asbestos cement, corrugated or semi corrugated sheets in roofs fixed with L- type or J- type cranked hook bolts complete all as specified and directed.
All as per Serial item No 27 but except sheet.
Material & Labour for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws for ceiling complete all as specified and directed.(Make: Everest/Charminar/Rhino)
Material & Labour for 2nd class hard wood (well seasoned) scantling clean sawn,as in timber fixed work complete all as specified and directed.
All as per Serial item No 30 but except timber.
Material & Labour for 2nd class hard wood (well seasoned) plain fillets, square, rectangular or triangular in section area exceeding 13 Sqcm and not exceeding 25 Sqcm and secured with nails complete all as specified and directed.
Fixing only plain fillets, square, rectangular or triangular in section area exceeding 13 Sqcm and not exceeding 25 Sqcm.
All as per Serial item No 32 but section area exceeding 3 Sq cm but not exceeding 6 Sqcm complete all as specified and directed.
Material & Labour for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coat of creosote oil complete all as directed.
Material & Labour for Anodised aluminium snap grid frame work for false ceiling and Hangers 4 mm dia.(upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Demolition of precast cement concrete articles and precast concrete block walling built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc complete all as specified and directed.
Taking down cement plaster or brick or stone wall including raking out joints, hacking for key scrubbing down with water complete all as specified and directed.
Material & Labour for Pre-cast cement concrete block masonry with solid block type C1, (1:3:6) (20 mm graded aggregate) setting in CM 1:6 complete all as specified and directed.
Material & Labour for precast cement concrete solid building block or slabs type C1, 1:3:6 (20mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in CM 1:4 in walls complete all as specified and directed.
Material & Labour for Rendering 15 mm thick on concrete surface in CM 1:6 on walls even and smooth without using extra cement complete all as specified and directed.
Material & Labour for Rendering 15 mm thick on concrete surface in CM 1:4 on walls even and smooth without using extra cement complete all as specified and directed.
Material & Labour for Rendering 10 mm thick on concrete surface in CM 1:3 on ceiling surfaces even and smooth without using extra cement complete all as specified and directed.
Taking down existing steel rolling shutters from brackets area not exceeding 25 Sqm with all connected fittings such as shaft, helical spring, bearings, gear box, bottom plates, locking arrangements etc checking for its function replacing any worn out and unserviceable small parts like nuts & bolts etc as required, servicing and complete overhauling for smooth function and refixing to its original position as directed.
Supply & Fix main axial including top gear, connected rod and bottom up and down gear box system complete area of shutter not exceeding 25 Sqm complete all as specified and as directed.
Supply & Fix for rolling shutter lath made out of 1mm thick and 75mm width including one coat of red oxide primer complete all as specified and directed by Engineer-in- Charge.
Supply & Fix bottom plate for shutter 12 cm width 2.5mm thick to position including riveting bolting etc, area of shutter not exceeding 25 Sqm, complete all as specified and directed.
Supply and fixing shutter cover made out of 1mm thick MS Sheet including moulding, bending, welding same pattern as existing covers with complete fittings all as specified and directed by Engineer -in- Charge .
Supply & fix lock set made out of flat iron 40x5mm including welding bolting etc at bottom side as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Supply & Fix structural steel work in tubular trusses and as in purlin, rafter etc on roof including special shaped washer etc or including butt welded tubes conforming to IS:1161-1979 grade St-240 complete all as specified and as directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (without taking off shutter from the frame) and removing material from the site complete all as specified and directed.
All as per Serial item No 52 but not exceeding 1.5 Sqm each.
Taking down shutter of any description not exceeding 1 sqm each.
Taking down shutter of any description exceeding 1 sqm but not exceeding 2 sqm each.
Supply & Fix Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube,complete all as specified and directed.
Material & Labour for factory made solid single extruded panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gape inside for top rail and bottom rail: paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed PVC the style & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
Material & Labour for 2nd class hard wood well seasoned plain solid straight chowkhats framed wrought framed, rebated on the solid, round or chamfered put together with glue and pinned at joint and fixed in wall complete all as specified and directed.
Material & Labour for 35 mm thick well seasoned 2nd class hard wood paneled shutter any number of panels with panels of timber flat on both sides or commercial of veneered faced particle board, 12mm thick or 9-12 mm thick commercial ply wood BWP grade fitted to chowkhats complete all as specified and directed.
Material & Labour for 30 mm thick well seasoned 2nd class hard wood glazed and skeleton shutters as per open rebated and prepared to receive glass, gauge etc without sash bar, edge of framing plain chamfered or rounded mitered beads for securing glass any numbers complete all as specified and directed.
Material & Labour for 35 mm thick well seasoned 2nd class hard wood glazed and skeleton shutters as per open rebated and prepared to receive glass, gauge etc without sash bar, edge of framing plain chamfered or rounded mitered beads for securing glass any numbers complete all as specified and directed.
Material & Labour for 40 mm thick flush shutter, solid core construction, with particle board core and plywood face panel, commercial type on both sides complete all as specified and directed.
Material & Labour for 25 mm thick flush shutter, solid core construction, with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
Material & Labour for hold fast made out of Flat Iron (25X5)mm confirming Fe-410-1 or 310-0 complete all as specified and directed.
Material & Labour for cutting holes in to block wall built in cement mortar for inserting hold fast exceeding half brick not exceeding one brick and making good to dismantled portion with PCC (1:2:4) type B1 and CM (1:3) complete all as directed by EIC.
Supply & Fix MS butt hinges 100mm long cold rolled medium weight complete all as specified and as directed.
Supply & Fix MS butt hinges 75mm long cold rolled medium weight complete all as specified and as directed.
Supply & Fix 150 mm long Aluminium anodised tower bolt fixed with screw complete all as specified and directed.
Supply & Fix 100 mm long Aluminium anodised tower bolt fixed with screw complete all as specified and directed.
Supply & Fix 300 mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing and sliding bolt of extruded section and fixed to shutter with screw complete all as specified and directed.
Supply & Fix 150 mm long aluminium door handle cast type fixed to shutter with screw complete all as specified and directed.
Supply & Fix 125 mm long aluminium door handle cast type fixed to shutter with screw complete all as specified and directed.
Supply & Fix 100 mm long aluminium door handle cast type fixed to shutter with screw complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality) from wooden frames, glazed with putty or fixed with beads complete as directed by EIC.
Supply & Fix 100 mm size Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Supply & Fix 3mm thick sheet glass ordinary quality and glazing with oil putty/beading in squares or rectangular in squares not exceeding 0.5 Sqm each pane complete all as specified and directed
Supply & Fix aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of aperture 1.4mm cut to size and fixed to doors/window shutters and fixed with aluminium wire staples as ordered complete all as specified and directed.
All as per Serial item No 77 but fixing only in repair.
Demolition of unreinforced concrete in roof floor (other than ground floor) beams stair case and similar suspended work including removal of debris from the site complete all as directed.
Supply and Brushing neat cement slurry @ 3.00 Kg of cement per Sqm with WPC. Note: - WPC will be measured and paid separately.
Material and Labour for 25 mm thick Cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor finished even and fair.
Rendering 15mm thick on fair faces of concrete surfaces in CM 1:3 finished even and smooth without using extra cement with using WPC. Note: - WPC will be measured and paid separately.
Supply only Integral water proofing compound.
Material & Labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces.
Material and Labour for applying oil bound bitumen primer @ 200gm/Sqm providing and laying 4 mm thick APP modified water proofing membrane weighing not less than 4 Kg/Sqm having reinforced with non woven Polyester matt weighing not less than 160 gms/sqm softening point not less than 140 degree centigrade , longitudinal tensile strength of 180 N by torch on application including min 10 cm side overlap and 15 cm end laps applying a coat of blown grade hot bitumen 90/15 @ 1.2 Kg/Sqm over the membrane and finishing with solar reflective bituminous aluminium paint @ 100 gm/Sqm complete all as specified and as directed
Material & Labour for two coat of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces over 10 cm width or girth complete all as specified and as directed.
Material & Labour for two coat of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces not exceeding 10 cm width or girth complete all as specified and as directed.
Material and Labour for one coat of synthetic enamel paint including preparation of old wooden surface over 10 cm width or girth complete all as specified and as directed.
Material and Labour for three coat of white wash on ceiling surface including preparation of new surface complete all as specified and as directed.
Material and Labour for preparation of new plastered surfaces of wall and applying two coat of OBD over one coat of priming coat complete all as specified and as directed.
Material and Labour for one coat of OBD including preparation of old wall surfaces complete all as specified and directed.
Material and Labour for two coats of cement paint over one coat of alkali resistant primer including preparation of new wall surfaces complete all as specified and directed.
Material and Labour for one coat of cement paint including preparation of old wall surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces exceeding 10 cm width or girth after preparation of surfaces complete all as specified and as directed
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces not exceeding 10 cm width or girth after preparation of surfaces complete all as specified and as directed
Supply & Fix in repair 20mm dia aluminium anodised curtain rod including brackets finials for holding curtain rod and ring complete all as directed.
Supply & Fix glazed aluminium anodized (15 Micron) aluminium door made out of aluminium extruded section 100x45x2.6mm thick for shutter section, 47x45x2.6mm thick for rails except bottom rail. The section for bottom rail shall be 100x45x2.6mm complete with hydraulic floor mounted door closer ISI marked, aluminium extruded handles 300mm long, six lever, cylindrical lock (make-Godrej) 150mm long tower bolt-03 Nos, 5.5mm thick glass pane including neoprene dry set rubber gasket entire complete all as specified and directed.
Supply & Fix glazed aluminium anodized (15 Micron) sliding window with three track. All section will be 90x30mm and 2.6mm thick all material complete with suitable aluminium anodized handle, cleat, glazing clips, 4.8 mm thick glass sheet with neoprene dry set rubber gasket with and including aluminium deco grill of suitable size complete all specified and directed.
Supply, fabricated and fixed aluminium channel, angle in bay section as in partition including glazing clip rubber gasket, fixing in wall and floors using dash fastener with chromium plated MS screws etc complete all as directed.
Supply & Fix 5mm thick sheet glass ordinary quality, and glazing with oil putty/wooden beads in squares exceeding 0.5 sqm each pane complete all as specified and directed.
Supply and Fix in repair Towel rail 600mm long of PTMT fixed with and including CP brass crews and wooden/plastic cleats complete all as specified and as directed
Supply and Fix in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed
Supply and Fix in repairs grating doom 100mm dia of PTMT complete all as specified and as directed
Supply & Fix in repair 15mm bore Pillar taps, cast copper alloy, CP, chromium plated, screwed down high pressure, screwed for iron pipe or CPVC pipe and fixed complete all as specified and as directed.
Supply and Fix in repair for WC vitreous china squatting pan Orissa pattern 580x440mm white with integral foot rest fixed complete all as specified and as directed
Supply & Fix in repair wash basins white flat black size 580x450mm excluding taps, waste couple & waste pipe but including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed.
Attending internal/External electric complaints for maintenance/breakdown round the clock for maintenance, Checking, Fault finding and rectification of fault in LT Panels/Overhead HT/LT Lines, HT/LT underground cables, Transformers, Switchgears internal electric faults, geysers, fans etc including internal/external water supply complaints and carry out repairs and resume electric supply and water supply complete all as specified and directed by Engineer-in-Charge. Notes: - (a) Day to day complaint rectified by the electrician shall be written in complaint register and complaint document slip, rectified complaints only shall be measured and paid. Complaint attender shall have minimum qualification of ITI electrician cum plumber having 2 years experience of same nature of work is to be employed. (b) The Spares required for rectification of faults shall be measured under relevant items. (c) All necessary Tools shall be available with the contractor while executing the compliant. (d) All consumables other than mentioned in Schedules are deemed to be included in the rate quoted. (e) All kind of transport for the complaint attender/materials and mobile / cell charges are deemed to be included in the rate quoted. (f) All safety aspects are to be taken and if any accident/hazardous incidents happen during execution shall be the sole responsibility of the Contractor.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed
Material and labour for point wiring on surface/ceiling/Trusses/existing concealed conduit with 1.5 sqmm PVC insulated unsheathed single core multistranded copper conductor cable, FRLS, ISI marked drawn through and including PVC conduit of suitable size and all accessories, fire resistant, ISI marked including 2 mm thick and 60mm depth GI sheet pressed terminal box ( recessed) with 3 mm thick laminated hylum sheet top cover including 1.50 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity conductor and making good the disturbed surfaces of walls, floors, ceiling etc all as specified and directed for One light point controlled by one switch.
Ditto as per item No 110 but for One ceiling fan point controlled by one switch.
Ditto as per item No 110 but for One exhaust fan point controlled by one switch.
Ditto as per item No 110 but for One 3 pin 5 Amps socket outlet controlled by one switch on independent board.
Ditto as per item No 110 but for One 3 pin 5 Amps socket outlet controlled by one switch in the same board with other switches.
Ditto as per item No 110 but for One bell point controlled by one bell push.
Ditto as per item No 110 but for One light point controlled by 2 Nos two way switches.
All as per item No. 110 above but with 2.5 Sq mm cable for wiring and 1.50 Sqmm cable as earth continuity conductor for one 16 Amps switch socket outlet on independent board.
Material and labour for point wiring on surface/ceiling/Trusses/existing concealed conduit with 1.5 sqmm FRLS single core multi stranded copper conductor cable drawn through and including ERW steel conduit of suitable dia including 1.5 sqmm FRLS copper conductor cable as earth continuity conductor complete for one light/exhaust fan point controlled by one switch.
All as per item No. 118 above but for One 3 pin socket outlet, 15 amps, independent, with cables 4 Sqmm size
Supply and Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified directed.
Supply and fix in repairs switch piano, flush type, 6 Amps, SP, one way, all as specified and directed.
Supply and fix in repairs switch piano, flush type, 6 Amps, SP, two ways, all as specified and directed.
Supply and fix in repairs bell push, flush type, 6 Amps, all as specified and directed.
Supply and fix in repairs socket outlet, flush type, 6 Amps, 2/3 pin, all as specified and directed.
Supply and fix in repairs switch socket combination, 2/3 pin, 06Amps, flush type, all as specified and directed.
Supply and fix in repairs switch socket combination 6 pin 6/16Amps, flush type, multipurpose, all as specified and directed.
Supply and fix in repairs ceiling rose, surface type, bakelite, 65x50mm, 3 terminals, all as specified and directed.
Supply and fix in repairs plug top, 3 pin 16 Amps, 240V, Bakelite body, all as specified and directed.
Supply and fix in repairs call bell, AC, 230 Volts, single pole, all as specified and directed.
Supply and fix in repairs, fan regulator, electronic socket type, hum proof, AC, 240 Volts, 5 step, two module all as specified and directed.
Supply and fix in repairs, fan regulator, electronic socket type, hum proof, AC, 240 Volts, single module all as specified and directed.
Supply and fix in repairs lamp holder, pin type, insulated body with back plate suitable for batten fittings, AC, 240V, all as specified and directed.
Supply and fix fluorescent LED tube light fitting, 1x20W, 230V,with extruded aluminium housing and high quality PC Diffuser, efficacy of 110/125 Lumen/watt including LED lamp of 20W complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fix fluorescent LED tube light fitting, 1x10W, 230V,with extruded aluminium housing and high quality PC Diffuser, efficacy of 100 Lumen/watt including LED lamp of 10w complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fix LED Tube lamp suitable for 4 feet, 18/20w all as specified and directed.
Supply and fix CIMFR certified LED flameproof batten suitable for twin T8/T5 tube of 20W. Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected including LED lamp 20W.
Supply and fix CIMFR certified LED flameproof batten suitable for single T8/T5 tube of 20W. Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected including LED lamp 20W.
Supply and fix CIMFR certified LED fitting flameproof 60W Well glass in die cast aluminium housing with heat resistant toughened glass. Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP 65 Protected.
Material and labour for sub main wiring with 2 runs of 4 Sq mm PVC insulated unsheathed single core multistraded copper conductor cable, FRLS, ISI marked and one run of 4 Sq mm multistranded insulated copper conductor cable, FRLS, ISI marked as earth continuity conductor drawn through and including PVC conduit of suitable size and all accessories, not less than 2mm thick, fire resistant, ISI marked and making good the disturbed surfaces of walls / floors / ceiling etc and including removing the existing aluminium sub main wiring cable, all as specified and directed.
Ditto all as per item Sl Item No 139 but drawn through ERW Steel conduit
Supply and fix in repairs sheet metal enclosure for MCB DB TPN 4 ways, 415V with 200 Amps bus bar, double door, all as specified and directed.
Supply and fix in repairs sheet metal enclosure for MCB DB SPN 8 ways, 240V, with 200 Amps bus bar, double door, all as specified and directed.
Supply and fix thermoplastic polycarbonate VTPN DB, 4 way, 415 Volts with 125A bus bar, in accordance with IEC 61439-3 hinged double door type shock proof, Rust free, Corrosion free, acid and chemical resistance, fire retardant, self extinguishing, PE+N terminals suitable to fix MCB/RCCB as incomer, IP 66 Protection, Flush type with glands, lux etc for connection of cables including dismantling old one all as specified and directed.
Ditto as per item No 143 But for SPN 12 way/Module with DIN rail.
Supply and fix thermoplastic polycarbonate SPN DB, 4 way/module, 220 Volts, in accordance with IEC 61439-3 hinged flap type shock proof, Rust free, Corrosion free, acid and chemical resistance, fire retardant, self extinguishing, PE+N terminals, IP 65 Protection including dismantling old one all as specified and directed.
Ditto as per item No 145 But for SPN 8 way/module.
Supply and fix in repairs MCB SP, 6 to 32 Amps, 220 Volts, 10 KA, 'C' series all as specified and directed.
Ditto as per item No. 147 above, but MCB SPN 32 Amps,220 Volts, 10 KA, 'C' series
Ditto as per item No. 147 above, but MCB TPN 63 Amps, 415 Volts, 10/16 KA, 'C' series.
Supply and fix in repairs SPN sheet metal enclosure with a two in and earth plug and socket complete with one MCB SP 10 Amps, 240V and connecting complete, all as specified and directed.
Ditto all as per item Sl Item No 150 but with one MCB SP 20 Amps.
Supply and fix in repairs SPN sheet metal enclosure with a three pin and earth plug and socket complete with one MCB TP 32 Amps, 415V and connecting complete, all as specified and directed.
Ditto all as per item Sl Item No 152 but with one MCB TP 63 Amps.
Supply and fix in repairs RCCB, double pole, 40A, 30mA, and 240V, all as specified and directed.
Supply and fix in repairs RCCB, four pole, 63A, 30mA, and 415V, all as specified and directed.
Supply and fix Thermoplastic polycarbonate IP 65 energy meter enclosure environment friendly, Corrosion proof, chemical resistant weather proof suitable to fix energy meter inside Size of 600 x 600 x 170 mm.
Supply and fix Thermoplastic polycarbonate IP 65 energy meter enclosure environment friendly, Corrosion proof, chemical resistant weather proof suitable to fix energy meter inside Size of 300 x 300 x 170 mm.
Material and labour for Earthing with galvanised MS earth plate of size 600 x 600 x 6 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by GI earth strip of size 32 x 6 mm thick, soldered and riveted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009. Note: - Main earthing lead from earth plate to test point & up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Ditto as pr item Sl Item No 158 But using 4 mm dia earth wire
Disconnecting and taking down fans, any size, any make, from various satellite area locations, for repair /painting / replacement of defective parts and re-hanging / re-fixing in its original location after reconditioning, complete as specified and directed for Ceiling Fan 1200mm/1400 mm Sweep, Wall fan upto 450 mm and exhaust fan upto 450 mm sweep. Note: - Items for reconditioning will be measured and paid separately.
Material and labour for removing the burnt out winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, varnishing, drying etc, replacement of body screws, testing and commissioning on full load for 8 hours continuous running, for Ceiling Fan 1200mm/1400mm Sweep complete as specified and directed. Note: - Items for reconditioning will be measured and paid separately.
Ditto as per item No 161 But for Wall Fan and Exhaust fan upto 450mm Sweep
Material and labour for Preparing the surface by scraping and removing the existing painting, cleaning, filling the cavities and applying 2 coats of spray paint of synthetic enamel white / brown colour over a coat of red oxide zinc chromate primer, including writing the MES Nos. as specified & directed for Ceiling Fan 1200mm/1400mm Sweep.
Ditto as per item No 163 But for Wall Fan/Exhaust fan upto 450mm Sweep
Supply and replacement of Condenser / Capacitor 2.5/4 MFD, 240V, AC suitable for fans, all as specified and directed.
Supply and replace ball bearing made out of high carbon steel, as per existing, suitable for any type, any make, any size fan, all as specified and directed.
Supply and replace bush bearing, made out of brass alloy, as per existing, suitable for any type, any make, any size fan, all as specified and directed.
Supply and replace down rod, suitably holed, made out of 15mm dia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size, all as specified and directed.
Supply and replace nut, bolt, split pin made out of nickel plated mild steel with rubber reel insulator, suitable for ceiling fans any type, any make, any size, including dismantling old one all as specified and directed.
Supply and replace, bakelite body nichrome connectors, 2 way, with fixing screws of suitable size for ceiling fans of any type, any make, all as specified and directed.
Supply and replace 1100 Volts grade PVC flexible twisted twin core cable with multistranded copper conductor of size 23/0.0076, all as specified and directed.
Taking down defective Geyser of capacity 25/ 50 litres of any make from its existing position after disconnecting inlet/outlet water connection and opening of geyser for checking and repairing the defective parts including testing and commissioning the same after successful repairing painting with synthetic enamel paint(duco) by spraying after preparation of the steel surfaces and re-fixing the same on its existing position and making connection inlet/outlet water connection complete all as specified and directed. Notes:- (i)The replaced defective parts will be measured and paid separately as supply only items under the relevant items of this BOQ (ii)Labour charges required for replacement of spares shall deemed to be included in the unit rate quoted by the tenderer. (iii) Items for reconditioning will be measured and paid separately.
Supply and replace Heating element any type for 1.5KW/2KW capacity, 240V, AC, with heat resistant rubber washer complete, all as specified and directed.
Supply and replace Thermostat control unit suitable for 25/50 Litres capacity geysers, 30-90 degree rating, any type, 240V, AC and connecting complete, all as specified and directed.
Supply and replace indicator lamp round / rectangular type, standard quality, AC, SP, 230V, Red or Green and connecting complete, all as specified and directed.
Supply and replace fusible plug with internal or external threading suitable for geysers of capacity 25/50 liters, all as specified and directed.
Supply and replace non-return valve, made out of brass 15mm bore, all as specified and directed.
Supply and replace PVC sheathed, multi stranded copper conductor, 3 core, flexible cable, 1100 V grade, size 40/0.0076, AC and connecting complete, all as specified and directed.
Fabricate and replace, GI bottom cover / inspection plate, 2 mm thick, split type, as per sample, duly painted with 2 coats synthetic enamel paint over a coat of red oxide zinc chromate primer to match with the existing colour for any type/size of Geysers all as specified and directed.
Preparing the surface of 25/50 Litres capacities of geyser by scraping and removing the existing painting, cleaning, filling the cavities and applying two coats of spray paint with synthetic enamel white paint over a coat of red oxide zinc chromate primer, including writing the MES Nos. complete all as specified & directed.
Material and labour for making 4 Nos of holes in wall, grouting 4 Nos rag bolts of size 125mm long x 12mm dia with PCC including necessary nuts and washers for 25/50 Litres capacities of geyser on wall complete, all as specified and directed.
Supply and replace inner assembly made out of brass with chromium plating, suitable for any type of Geysers for 25/50 Litres capacities all as specified and directed.
Material and labour for filling the glass wool between outer cover and inner tank of Geysers, 50/25 litres capacity, horizontal / vertical, complete all as specified and directed.
Supply and fix metallic outer cover including bottom and top cover duly spray painted with 2 coats of synthetic enamel paint over a coat of red oxide chromate primer, suitable for any type of geyser for 25/50 Litres capacities complete all as specified and directed.
Supply and replace inner tank made out of copper alloy, suitable for any type of geyser, for 25/50 Litres capacities complete, all as specified and directed.
Material and labour for repairs to metallic inner tank, arresting the leakage by welding, brazing etc, pressure testing after repairs, for any type of geyser for 25/50 Litres capacities complete, all as specified and directed.
Supply and replace pressure / air release valve suitable to fix in inlet of geyser, made out of brass 15mm bore, all as specified and directed.
Material & Labour for disconnecting from position, Transporting to local workshop for servicing including cleaning of interior parts and body with solvent materials, replacement of unserviceable spares / parts if required, necessary repairs, Transporting back, Installing at its original location, Connecting, Testing and commissioning of water cooler upto 120 litres, Ozone based filter type hot and cold water cooler 85 litres cap, Refrigerator upto 310 litres cap all as specified & directed. Note:- Spares will be measured and paid separately
Material & Labour for disconnecting from position or electric supply, servicing at same location including cleaning of interior parts and body with solvent materials, replacement of unserviceable parts, necessary repairs, Re-Connecting, Testing and commissioning of water cooler upto 120 litres, Ozone based filter type hot and cold water cooler 85 litres cap, Refrigerator upto 310 litres cap all as specified & directed. Note:- Spares will be measured and paid separately
Supply & Fix factory reconditioned Hermetically sealed compressor unit suitable for water cooler upto 120 litres, Refrigerator upto 310 litres for exchange of the existing unserviceable sealed compressor unit including initial charging of gas and oil all as specified & directed.
Supply & Fix Condensing coil made out of copper tube and aluminium fins suitable for water cooler upto 120 litres, Refrigerator upto 310 litres including necessary brazing, gas charging, leak testing, Vacuumising etc all as specified and directed.
Supply & Fix Evaporator coil of made out of Copper tube suitable for Refrigerator of capacity upto 310 Litres
Supply & Fix D S Candle suitable for Hot and Cold water cooler
Supply & Fix Filter Carbon suitable for Hot and cold water cooler
Supply & Fix main board suitable for Hot and cold water cooler
Supply & Fix power supply PCB suitable for Hot and Cold water cooler
Supply & Fix Transformer suitable for Hot and cold water cooler
Supply & Fix Solenoid valve suitable for Hot and cold water cooler
Supply & Fix Pressure Pump suitable for Hot and cold water cooler
Supply and Fix Heater coil suitable for Hot and cold water cooler
Supply and Fix Thermostat set suitable for Hot and cold water cooler
Supply and Fix Compressor suitable for Hot and cold water cooler
Supply and Fix Cooling Thermostat for Hot and cold water cooler
Supply and Fix 3 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5Sqmm.
Ditto as per item No 204 but for 4.0Sqmm x 3 core
Supply and charging refrigerant gas up to required level including connected works such as pressure testing/Leak test with nitrogen before filling refrigerant gas complete for Split AC upto 3 TR all as specified and directed by Engineer-in-Charge
Ditto as per item No 206 but for Water cooler upto 120 litres cap/Refrigerator upto 310 litres capacity.
Material & Labour for servicing of Split AC indoor/outdoor unit upto 3 TR comprising through cleaning, lubricating of all moving parts, replacement of worn out screws, bolts, rectifying electric wiring defects etc to make the unit for smooth operation
Supply and replace compressor sealed unit of Split AC upto 3TR, replacement of copper tubing/capillary strainer etc including gas charging complete, testing and commissioning all as specified and directed by Engineer-in-Charge. Note: Cost of gas charging included in the quoted rates.
Supply and replace capacitors 6/10/36 mfd.
Supply and replace capacitors 80/100/120 mfd and 45 + 6 mfd.
Supply and replace starting relay suitable for Split AC upto 3TR, Water cooler upto 120 litres, Refrigerator upto 310 litres capacity.
Supply and replace thermostats suitable for Split AC upto 3TR, Water cooler upto 120 litres, Refrigerator upto 310 litres capacity.
Supply and replace overload protector suitable for Split AC upto 3TR, Water cooler upto 120 litres capacity.
Supply and replace condenser unit suitable for Split AC upto 3TR, including making of all connections as specified and directed by Engineer-in-Charge.
Supply and replace magnetic door gasket of refrigerator upto 310 Litres
Supply and replace top cover gasket of water cooler upto 120 litres capacity.
Servicing of voltage stabilizers AC single phase 2 to 5 KVA of any make by opening of the body, cleaning of internally, checking and tightening of all terminal connections including replacement of worn out terminal connectors, screws, bolts etc complete as directed by Engineer-in-Charge.
Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for Split AC upto 3TR and water cooler upto 120 litres capacity.
Supply and fixed Air filter suitable for 1.5/2.0/3.0 ton split type AC of any make complete all as directed.
Supply and fixed insulation for copper tubes of split type AC units, insulation type superior of size 3/8" diameter.
Supply and fixed insulation for copper tubes of split type AC units, insulation type superior of size 5/8"diameter.
Supply and fixed in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter.
Supply and fixed in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter.
Supply and fixed PCB circuit board complete suitable for 1.5/2.0/3.0 ton capacity split type air conditioner
Supply and fixed push cock/tap as per existing suitable upto 120 litres capacity water cooler as per existing.
Supply and fix 20mm outer dia high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings, fixed to walls/floors /ceiling or concealed in wall and jointed with yellow solvents cement including taking down Unserviceable GI tubing complete all as specified and directed.
Supply and fix 20 mm bore CPVC ball valve suitable for CPVC pipe including necessary fittings, and taking down the old unserviceable gun metal gate/globe valve etc. complete all as specified and as directed.
Supply and fix in replacement of 20mm stop valves concealed fancy type chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends for unions or CPVC/GI pipe, complete all as specified and as directed.
Supply and fix in repair 15mm bore angle valve quarter turn with wall flange type chromium plated for fixing with CPVC/GI pipe, complete all as specified and as directed.
Supply and fix in repair 15mm bore bib tap Chromium plated quarter turn with flange , fancy type short body/long body cast copper alloy with crutch or butterfly handle screwed for GI/CPVC pipe including taking down the Unserviceable one complete all as specified and as directed.
Supply and fix in replacement shower rose brass chromium plated fancy type swivel type of bore 15mm and face dia 50mm (minimum) with CP cup and shower arm of 195 mm long with a bend of 45 degree all as specified and directed.
Supply and fix in repairs low density polyethylene (LDPE) pipe 16 mm dia (outer), 450 mm long suitable for hot/cold water application with brass union on both sides to suit 15 mm bore G.I pipe, complete as specified and directed.
Supply and fix in repair 15mm size health faucet, ABS body, with wall hook and 1 metre stainless steel braided rubber hose pipe including taking down the unserviceable one complete all as specified and as directed.
Supply and fix in repair PVC valve less, syphonic action type, flushing cistern, low level, and white, with inlet, ball valve, float and handle including brackets.
Supply and fix 20 mm bore float valve synthetic (PTMT) high pressure with polythene ball of size 6" dia and fly nut including taking down the Unserviceable one complete all as specified and as directed.
Material and labour for Cleaning and removing all scale and dirt, etc, from inside of Rotational moulded polyethylene water storage tanks and from mouths of circulating pipes, etc of tank size exceeding 250 Litres and not exceeding 500 litres capacity.
Ditto as per item No 237 but of Size exceeding 500 litres & not exceeding 1000 litres capacity.
Ditto as per item No 237 but of Size exceeding 1000 litres & not exceeding 2000 litres capacity.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
RASNA ENTERPRISES
ZOOM ENTERPRISES
Palakkal Agencies
PHEJAYS AGENCIES
M-TECH ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .