Loading…
Loading…
Tender ID
Tender Value
₹2.0 Cr
EMD Value
₹2 L
Closing Date
17 Mar 2026, 6:00 pmClosed
Executive Engineer, Navsari (R&B) Division, Navsari
Construction of Category D Type 04 Unit at Navsari, Dist. Navsari
282759
36 of 2025-26
Open
Civil Works - Buildings
Works
Navsari
9 documents required · 8 mandatory · 1 optional
₹3,600
Yes
Executive Engineer, Navsari (R&B) Division, Navsari
₹2 L
Yes
3 Mar 2026
3 Mar 2026
3 Mar 2026
17 Mar 2026
3 Mar 2026
No figures
1 Excavation for foundation upto 1.5 m depth including 627.00 Cumt 120.01
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soil
2 Excavation for foundation for depth from 1.5 m to 414.00 Cumt 166.35
3.0 m including sorting out and stacking of useful
materials and disposing off the excavated stuff
upto 50 Meter lead.(B) Dense or Hard soil
3 Filling in foundation and plinth with sand in layers of 49.00 Cumt 471.69
20 cm. Thickness including watering ramming and
consolidating etc. comp.
4 Filling available excavated Earth (Excluding Rock) in 406.00 Cumt 133.65
trench plinth side of foundation . in layer not
excluding 20 cm in depth consolidation each
deposited layer by ramming and watering etc.
soil in layer of 20 cm in thickness including ramming
watering and consolidating etc. complete
6 Anti Termite System 231.00 Sqmt 134.33
P/L of Permenent piping technology Anti Termite
treatment before flooring work by installing LLDP
(Low linear density Polyethylene) tube of 8 mm O.D.&
6.4 mm I.D.With in Built Pressure Compenstaion chif
every 30 cm interval in the tube, having working
pressure of 2 kg/cm 2 and realese rate of 1.9 ltr/Hour
fixed by P-Clip and nails . The LLDP pipe shall be
installed at the entire periphery of the building and at
internal network of building depth of 20 to 200 mm
under floor every 2 to 3 mtr.c/c distance (adjustble as
per building layout ) & Ends of loop pass through a
PVC Elbow of minmum 32 mm ID at junction box of
wall and floor level, entring into a steel reinforcmed
grooved flexible pipe mini.22 mm LD leading into
junction box and during injecting chemicls for termite
control tretment. The anti-termite chemical
Lmidcloprid 30.5% SC Mix as per IS 6313(part-III)
shall be injected by the pressure pump diluted with
water @ 10.5 ml/5ltr of water at the rate of
kg/sq,cm.@ 5 ltr /Smt .the contractor shall submit
approved line plan for piping system and junction
boxes dully approved By Engineer -in-charge with
bond of 5 Years warnty .
Item Rate In
Description of Item Quantity Unit Amount
No figures
7 Providing and laying cement concrete 1:3:6 (1- 43.00 Cumt 3080.90
Cement : 3- coarse sand : 6- machine cut stone
aggregates 40 mm nominal size) and curing complete
excluding cost of formwork in (A) Foundation and
8 Providing and laying controlled cement concrete 93.56 Cumt 4141.10
M150 for curing complete including cost of formwork
but excluding the cost of reinforcement for reinforced
concrete work in (A) Foundations, footings,Base of
columns, Plinth Slab and Mass concrete.
9 Providing and laying controlled cement concrete 173.00 Cumt 4549.04
M250 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (A) Foundations, footings and Mass
10 Providing and laying controlled cement concrete 14.00 Cumt 7254.12
M250 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts
and struts Column Up to Ground Level
11 Providing and laying controlled cement concrete 40.00 Cumt 7204.77
M200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts
and struts Ground Floor to upto FF
12 Providing and laying controlled cement concrete 16.00 Cumt 7245.30
M200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts
and struts Second Floor
13 Providing and laying controlled cement concrete 8.00 Cumt 7285.83
M200 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars posts
and struts Third Floor
14 Providing and laying controlled cement concrete 35.00 Cumt 6154.33
M250 and curing complete including the cost of form
work but excluding the cost of reinforcement for
reinforced concrete work in Ground & Plinth BEAMS
15 Providing and laying controlled cement concrete 45.00 Cumt 5232.00
M150 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Plinth Slabs
16 Providing and laying controlled cement concrete 39.00 Cumt 6114.67
M200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Ground Floor Beams to upto FF
Item Rate In
Description of Item Quantity Unit Amount
No figures
17 Providing and laying controlled cement concrete 21.00 Cumt 6155.20
M200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Second Floor Beams
18 Providing and laying controlled cement concrete 4.00 Cumt 6195.73
M200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Third Floor Beams
19 Providing and laying controlled cement concrete 2.00 Cumt 6270.87
M200 and curing etc. complete including the cost of
form work and reinforcement for reinforced concrete
work in (C) Chhajja for Ground Floor to upto FF
20 Providing and laying controlled cement concrete 2.00 Cumt 6311.40
M200 and curing etc. complete including the cost of
form work and reinforcement for reinforced concrete
work in (C) Chhajja for Second Floor
21 Providing and laying controlled cement concrete 1.00 Cumt 6351.93
M200 and curing etc. complete including the cost of
form work and reinforcement for reinforced concrete
work in (C) Chhajja for Third Floor
22 Providing and laying controlled cement concrete 1.50 Cumt 7403.05
M200 and curing etc. complete including the cost of
form work and reinforcement for reinforced concrete
work in (C) Lintal for Ground Floor to upto FF
23 Providing and laying controlled cement concrete 1.50 Cumt 7443.58
M200 and curing etc. complete including the cost of
form work and reinforcement for reinforced concrete
work in (C) Lintal for Second Floor
24 Providing and laying controlled cement concrete 0.10 Cumt 7484.11
M200 and curing etc. complete including the cost of
form work and reinforcement for reinforced concrete
work in (C) Lintal for Third Floor
25 Providing and laying controlled cement concrete 68.00 Cumt 6619.12
M200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Ground Floor Slab to upto FF
26 Providing and laying controlled cement concrete 34.00 Cumt 6659.65
M200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Second Floor Slab
27 Providing and laying controlled cement concrete 5.00 Cumt 6700.18
M200 and curing complete including the cost of
formwork and excluding reinforcement for reinforced
concrete work in (C) Third Floor Slab
Item Rate In
Description of Item Quantity Unit Amount
No figures
28 Providing and laying controlled cement concrete 7.00 Cumt 8270.61
M200 and curing etc. complete including the cost of
form work and excluding the cost of reinforcement
etc. complete in (E) Stair case for Ground Floor to
First floor
29 Providing and laying controlled cement concrete 3.00 Cumt 8311.14
M200 and curing etc. complete including the cost of
form work and excluding the cost of reinforcement
etc. complete in (E) Stair case for Second Floor to
Third Floor
30 Providing and laying controlled cement concrete 4.00 Cumt 10319.39
M200 and curing etc. complete including the cost of
form work and excluding the cost of reinforcement
etc. complete in RCC Vertical and Horizontal wall up
31 Providing and laying controlled cement concrete 3.00 Cumt 10359.93
M200 and curing etc. complete including the cost of
form work and excluding the cost of reinforcement
etc. complete in RCC Vertical and Horizontal wall for
Second Floor
32 Providing and laying controlled cement concrete 13.00 Cumt 10400.46
M200 and curing etc. complete including the cost of
form work and excluding the cost of reinforcement
etc. complete in RCC Vertical and Horizontal wall for
Third Floor
33 Providing and laying controlled cement concrete 4.50 Cumt 6350.09
M200 for RCC work and curing complete including
the cost of form work but excluding the cost of
reinforced concrete work in Coping on Ground Floor
to upto FF
34 Providing and laying controlled cement concrete 0.50 Cumt 6390.62
M200 for RCC work and curing complete including
the cost of form work but excluding the cost of
reinforced concrete work in Coping on Second Floor
35 Providing TMT Bar FE 550D reinforcement for R.C.C. 58718.00 Kg 95.45
work including bending, binding and placing in
position complete upto floor two level
36 Providing, laying and fixing 30cm Height SS Railing 80.00 Rmt 1862.04
made from anticorrocive up of RCC Perapet Wall on
fixing Hand Railing 50 mm dia (16 Gauge) MS Round
Hollow pipe horizontal 4 Nos and 38mm dia vertical
connection pipe 3 No with all material , laboure
charges and accessories as per requirement as
directed by Engineer-in-charge etc. complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
37 Providing and fixing 90 cm high SS railing made from 24.00 Rmt 4718.72
anti-corrosive SS 304 grade pipe of 50 mm diameter
(16 gauge) as hand rail, with SS 304 grade baluster of
38 mm diameter (16 gauge) as vertical supports fixed
in RCC slab at 1.20 m centre-to-centre, including
supply and fixing of 50 mm dia SS pipe, 38 mm dia SS
pipe for supports, 25 mm horizontal members,
mm supports, round ball caps, all necessary brackets,
welding, grinding, finishing, preparation and fixing,
labour charges, tools, tackles, scaffolding, handling,
loading/unloading, and all incidental works complete
in all respects as per direction of Engineer-in-Charge.”
As per directed by Engineer-in charge for All floor .
38 Brick work using common burnt clay building bricks 31.00 Cumt 4153.07
having crushing strength not less than 35 kg./Sq.Cm.
in foundation and plinth in Cement Mortar 1:5. (1-
Cement : 5 -fine sand) (B) Conventional below plinth
39 Brick work using common burnt clay building bricks 102.00 Cumt 4434.92
having crushing strength not less than 35 kg./Sq.Cm.
in foundation and plinth in Cement Mortar 1:5. (1-
Cement : 5 -fine sand) (B) Conventional {Ground
Floor to upto FF
40 Brick work using common burnt clay building bricks 59.00 Cumt 4476.42
having crushing strength not less than 35 kg./Sq.Cm.
in super structure in Cement Mortar 1:5. (1- Cement :
5 -fine sand) (B) Conventional {Second FLoor}
41 Brick work using common burnt clay building bricks 12.00 Cumt 4517.92
having crushing strength not less than 35 kg./Sq.Cm.
in super structure in Cement Mortar 1:5. (1- Cement :
5 -fine sand) (B) Conventional {Third FLoor}
42 Half Brick masonry in common brunt clay building 47.00 Sqmt 669.34
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
coarse sand ) in foundation and plinth (B)
Conventional in super structure. for Ground Floor to
43 Half Brick masonry in common brunt clay building 47.00 Sqmt 675.49
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
coarse sand ) in foundation and plinth (B)
Conventional in super structure. for Second Floor.
44 Providing and fixing 150 mm wide, approved quality 254.00 Sqmt 295.12
chicken wire mesh at junction of brick work and RCC
work or two dissimilar surfaces, at all heights fixed by
nails, rowal plugs or tag by cement mortar 1:3 before
applying the plaster, including curing, scaffolding all
complete as directed.
Item Rate In
Description of Item Quantity Unit Amount
No figures
45 Providing 20 mm thick double coat mala cement 607.00 Sqmt 285.35
plaster on interior brick / concrete work for
plastering comprising of base coat of 12 mm thick
cement plaster in cement mortar (1 Cement : 4 coarse
sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand)
finished with trovel including scaffolding curing etc.
complete. with 10mm grooves at juction of structural
members etc. comp. For Ground Floor to upto FF
46 Providing 20 mm thick double coat mala cement 539.00 Sqmt 312.74
plaster on interior brick / concrete work for
plastering comprising of base coat of 12 mm thick
cement plaster in cement mortar (1 Cement : 4 coarse
sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand)
finished with trovel including scaffolding curing etc.
complete. with 10mm grooves at juction of structural
members etc. comp. For Second Floor
47 Providing 20 mm thick double coat mala cement 187.00 Sqmt 340.13
plaster on interior brick / concrete work for
plastering comprising of base coat of 12 mm thick
cement plaster in cement mortar (1 Cement : 4 coarse
sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand)
finished with trovel including scaffolding curing etc.
complete. with 10mm grooves at juction of structural
members etc. comp. For Third Floor
48 Providing 10 mm. Thick mala cement plaster in single 695.00 Sqmt 155.55
coat for plastering on ceiling and soffits of stairs and
finished even and smooth in : (I) Cement mortar 1:4
(1 cement : 4 sand) with 1 x1 cm grooves at juction of
structural members etc. complete. Ground Floor to
49 Providing 10 mm. Thick mala cement plaster in single 340.00 Sqmt 182.94
coat for plastering on ceiling and soffits of stairs and
finished even and smooth in : (I) Cement mortar 1:4
(1 cement : 4 sand) with 1 x1 cm grooves at juction of
structural members etc. complete. Second Floor
50 Providing 10 mm. Thick mala cement plaster in single 32.00 Sqmt 210.33
coat for plastering on ceiling and soffits of stairs and
finished even and smooth in : (I) Cement mortar 1:4
(1 cement : 4 sand) with 1 x1 cm grooves at juction of
structural members etc. complete. Third Floor
51 20mm thick double coat sand faced cement gutka 1732.00 Sqmt 369.66
plaster on walls upto height 10 metres above ground
level consisting of 12mm thick backing coat of C.M.
1:3 (1-cement : 3-sand) and 8mm thick finishing coat
of C.M. 1:1 (1-cement : 1-sand) including 1cm x 1cm
grooves etc. complete. and as per pattern sample
aprroved by the architect or directed engineer in-
Item Rate In
Description of Item Quantity Unit Amount
No figures
52 Providing throating or plaster drip and moulding to 36.00 Rmt 43.22
R.C.C. Chhajja.
53 Applying two coats of Acrylic lapy (putty) & two coats 2332.00 Sqmt 40.59
of primer of approved brand and manufacture on new
wall surface to give an even shade including
thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered
54 Wall painting (three coats) with plastic emulsion 1265.00 Sqmt 122.58
paint of approved brand and manufacture on
undecorated wall surface to give an even shade
including throughly brushing the surface free from
mortar droppings and other foreign matter and sand
papered smooth.
55 Painting (three coats) with plastic emulsion paint of 1067.00 Sqmt 86.60
approved brand and manufacture on undecorated
ceiling surface to give an even shade including
throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered
56 Providing and applying textured finish of approved 506.00 Sqmt 71.71
pattern using acrylic-based exterior/interior grade
textured paint highlight in special effect ( Royal Play)
, including preparation of surface, filling of cracks
with approved filler, sandpapering, and making good
the surface, scaffolding etc., complete as per
manufacturer’s specification and direction of
Engineer-in-Charge.
57 Wall Painting (Two coats) with weather proof 100 % 1583.00 Sqmt 117.40
acraylic water repellant emulsion paint of approved
brand and manufacture and of required shade on
exterior wall surface to give an even shade over and
including primery coat with Alkaly resistance primer
of approved brand after thoroughly brushing surface
to remove all dust and remains of loose powdered
material etc. copm. for all height
58 Providing And filling with good quality cinder (steam 13.00 Cumt 522.78
coal) as directed by engineer in charge in sunks in
layers of 15 cm thick,including watering,placing
,ramming well etc as directed, for all floor.
59 Providing Water proofing Treatment on Sunk Slab 73.00 Sqmt 388.04
including cement concrete flooring 1:2:4 (1-cement :
2-coarse sand : 4-graded stone aggregate 20mm
nominal size) laid in one layer and finished with a
floating coat of neat cement average 50mm thick to
Prepare slope including water proofing chemical etc.
Complete for Sunk Slab All Floor.
Item Rate In
Description of Item Quantity Unit Amount
No figures
60 Providing and laying water proofing treatment with 130.00 Sqmt 1165.54
china mosaic tiles flooring over avg 50 mm C.C. 1:2:4
bedding for maintaining slope for plain and curve
surface & 12 mm to 20 mm of broken piece not more
than 2.5CM of ceramic / glazed tiles ( one for more
colour as directed ) to be laid over cement mortar
bedding of C M 1:3 (1 cement : 3 sand ) contain water
proofing materials per bag of cement useas specified
by manufactured and slops to be tempered to bring
mortar up to surface with using white cement and
colour pigment including rounding of junctions and
extending them up to 15 cm along the wall and curing
with bends any patens or design as per drawing and
cleaning by using oxalic acid etc. complete.
61 Providing and fixing in position standard extruded 34.50 Sqmt 4064.24
colour anodised aluminium four track sliding window
(3 shutters + 1 mosquito net shutter) made of
aluminium sections equivalent to Jindal Series-E (30
mm thick), comprising frame bottom with weep holes
(Section No. 20928), frame top and sides (Section No.
20837), shutter top and bottom (Section No. 20993),
shutter interlock (Section No. 20550) and shutter
side/handle section (Section No. 20549), glazed with
5 mm thick transparent tinted float glass fixed with
EPDM rubber gasket, air lock strip and finishing of
joints with silicone sealant, complete with powder
coated standard aluminium fittings, accessories,
rollers, locking arrangement, mosquito mesh shutter,
fasteners etc., including all materials, labour, tools and
equipment, complete as per specifications, detailed
drawings and as directed by the Engineer-in-Charge.
62 Providing & fixing in position standard extruded 3.50 Sqmt 5114.64
Aluminum Three track (2 shutter + 1 Mosquito net
shutter) with Standard Extruded Colour Anodied
Alluminium Section Equivalent to Jindal Series E (20
mm) Section Numbered: Frame -Bottom with Weep
Holes -20697, Frame Top & Side-20978 ,Shutter Top
& Bottom 20529, Shutter Inter Lock -20566 ,Shutter
Side (handle) -20530 With 5mm thick Transparent
Tinted Float Glass With EPDM Rubber Gasket, Air
Lock Stirip and Finishing , Joint With Section Sealant,
With Power Coated Standard Alluminium Fitting.with
as per window size including all required materials
labours and equipments as per detailed drwg. as
Item Rate In
Description of Item Quantity Unit Amount
No figures
63 Providing and fixing standard extruded colour 3.00 Sqmt 2310.88
anodised aluminium section equivalent to Jindal
section Frame-21458 with 5 mm thick frosted glass
adjustable louvers of approved standard make,
including EPDM rubber gasket, fittings, screws,
sealant, labour, tools & plants complete as per
direction of Engineer-in-Charge.
64 Providing and fixing Single shuttered door fixed by 55.50 Sqmt 3541.06
zinc coated hinges with single/duble shutter of
factory made & stamped I.S 2202 grade one, type one
35 mm thick solid core, melamine faced, three
layered resin, flushed door , having decorative
lamination on both sides & 12 mm thick teak wood
beading fixed around the door, Durable Grip shall be
providing with both side 15cm long stainless steel
handle and necessary Locking system, S.S. fixtures &
fastenings etc. directed by engineer in charge.
65 Providing & fixing 25mm thick cupboards of plywood 31.00 Sqmt 4283.41
shutter including fixing 19 mm and 6mm thick back to
back flush all proof plywood & including with Teak
Wood frame 50 mm x 50 mm size as directed etc.
complete including necessary both side lamination
mm thick outer side & 0.80mm thick inner side fixing
by necessary SS hinges, handles, magnet, stoppers,
etc. as directed including fevicol, and other hardware
material required. Plywood and all fixture shall be of
ISI quality and as approved by engineer-in-charge
including cost of teak wood beading, one coat of
primer and two coats of oil painting or polishing as
66 Providing and Laying 600mm x 600mm x 10 mm 295.00 Sqmt 1280.68
Double charged Vitrified tile flooring over With 3mm
Epoxy Groove jointed over 20 mm (average) base of
cement mortar 1:6 (1cement : 6 coarse sand)on new
surface with colour cement slurry including finished
with flush pointing & cleaning the surface etc.
complete (10% Dark colour tiles for pattern of same
67 Providing and Laying 600mm x 600mm x 10 mm 36.70 Sqmt 1437.23
Double charged Vitrified tile skirting , dedo, riser
over 10 mm (average) base of cement mortar 1:3
(1cement : 3 coarse sand)on new surface With 3mm
Epoxy Groove jointed with colour cement slurry
including finished with flush pointing & cleaning the
surface etc. complete (10% Dark colour tiles for
pattern of same material)
Item Rate In
Description of Item Quantity Unit Amount
No figures
68 Providing and laying 600 × 600 mm matt finish 27.00 Sqmt 1386.73
porcelain tiles in flooring, of approved make, shade
and pattern, laid on cement mortar bed (or adhesive
as specified) over prepared base, true to line and
level, With 3mm Epoxy Groove the joints with
approved epoxy grout of matching shade, complete as
per Directed by Engineer-in-Charge.
69 Providing and Laying 600mm x 600mm x 10 mm 20.00 Sqmt 1250.38
Matt Finished Glazed Vitrified (GVT) tile flooring
overWith 3mm Epoxy Groove 20 mm (average) base
of cement mortar 1:6 (1cement : 6 coarse sand)on
new surface with colour cement slurry including
finished with flush pointing & cleaning the surface
etc. complete (10% Dark colour tiles for pattern of
same material)
70 Providing and laying coloured glazed tiles of the size 217.80 Sqmt 1477.25
mm/ 300 mm x 600 mm x 8 mm in skirting, risers of
steps and dedo on 10 mm. thick cement plaster 1:3 (1
cement : 3 coarse sand) & including Groove jointed
with white cement slurry.
71 Providing and laying polished Kota stone slab flooring 16.50 Sqmt 1079.41
over With 3mm Epoxy Groove 20mm (Average) thick
base of cement mortar 1:6 (1-cement : 6-coarse sand)
or L.M. 1.1.5 laid over and jointed with grey cement
slurry including rubbing and polishing etc. complete.
(B) 30 mm thick
72 Providing and laying 10 to 12mm thick ready made 56.50 Sqmt 2601.76
Full body vitrified anti skid Flutes step tiles of
120x30cm Tread, 120x15cm riser & 60x60cm
Landing with 1cm projecting, nosing half rounded
moulding in tread , laid over 12 mm (av.) thick bases
of cement mortar 1:3 (1-cement : 3-coarse sand)
jointed with grey or colour cement slurry including
rubbing and polishing incl. Full body vitrified tiles
approved by directed engineer in charge.
73 Providing and fixing mirror polished 18 mm thick 96.00 Sqmt 2930.01
Black Granite stone with full round edge and polished
of approved quality in clading on sill and around the
doors/ windows/ ventilation with 12 mm thick
cement mortor CM (1:4) and fixing with cement
slurry & adhesive including moulding of exposed
edges as directed by engineering in charge etc.
Item Rate In
Description of Item Quantity Unit Amount
No figures
74 Providing and fixing pre-cast Rubber Dye inter 644.00 Sqmt 704.07
locking concrete block 60mm thick with grade of
concrete M30 pnumatic compressed by mechanically
pressed and as per approved design confirming to IS
15658: 2006 including 35mm Sand layer for levelling
and filling the joint with sand in proper line and level
as per guidelines of IRC SP 63-2018 etc complete.
75 Providinfg and fixing Safty grills of required pattern 1239.00 Kg 109.08
for windows/ Door using necessary 12x12 mm M.S.
Square bar, M.S flats and other structural steel at
required spacing including cutting, welding and
fabriction etc. including one coat of primer of
approved quality and two coats of oil painting as per
detail drawing etc complete.
76 Providing erecting and fixing double coated Syntex 6000.00 Litre 3.95
PVC. (ISI) water tank of required capacity each with
all necessary fittings and connection etc. complete on
77 Providing laying and jointing in true line and level 130.00 Rmt 195.67
50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp
at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
78 Providing laying and jointing in true line and level 120.00 Rmt 148.12
40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp
at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
79 Providing laying and jointing in true line and level 80.00 Rmt 91.84
25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp
at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
80 Providing laying and jointing in true line and level 90.00 Rmt 72.65
15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp
at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Item Rate In
Description of Item Quantity Unit Amount
No figures
81 Providing, laying and jointing in true line and level 60.00 Rmt 834.38
160 diametre U.P.V.C (Type B) conforming to IS
13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp of the size 160 mm diametre x 210 mm
length x 196 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all
materials.
82 Providing, laying and jointing in true line and level 100.00 Rmt 857.65
110 diametre U.P.V.C (Type B) conforming to IS
13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp of the size 110 mm diametre x 149 mm
length x 145 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all
materials.
83 Providing, laying and jointing in true line and level 75 30.00 Rmt 737.30
mm dia. UPVC SWRType B pipe conforming to IS
13592-1992 with one end plain and other end
socketed with rubbering and fitting conforming to ISI
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp at every 2000 mm c/c or shall be conceled
in walss as directed including necessary fittings such
as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement
including cost of all materials.
84 Providing and fixing in PVC SWR cowel went 75mm 2.00 No 16.16
dia to pipes.(B) 75mm dia.
85 Providing and fixing in PVC SWR cowel went 110mm 10.00 No 29.29
dia to pipes.(B) 110mm dia.
86 Providing and fixing PVC SWR Nahni trap IS 14735 for 18.00 No 585.37
drain - 100 mm diameter with jali of the following
nominal diameter of self cleansing design with C.I
scread down or hinged grating including the cost of
cutting and making good the walls.
Item Rate In
Description of Item Quantity Unit Amount
No figures
87 Providing and fixing wash down water closet 4.00 No 2497.73
(European type W C pan) with integral P and S trap
including jointing the trap with soil pipe in cement
mortar 1:1 (1 cement five sand) including providing
and fixing plastic seat cover for wash down WC with
CP brass hinges and rubber buffers back plastic seat
with a pair of C I or MS bracket with complete fitting
such as lead valve siphon 15 mm dia brass ball valve
with polythene float CP brass handle unions and
couplings for connection with inlet out let and over
flow pipes 40 mm dia porcelain enameled flush bend
including cutting holes in walls and making good the
same connection the flush bend with cistern and
closet vitreous china.
88 Providing and fixing Anglo Indian Toilet Commode 4.00 No 13197.67
Water Closet – P Trap White Ceramic EWC 535mm D
x 455mm W x 410mm H including jointing the trap
with soil pipe in cement mortar, cutting holes in
walls/floors and making good the same. The item
includes providing and fixing plastic seat cover with
C.P. brass hinges and rubber buffers, complete fittings
such as 15 mm brass ball valve with polythene float,
C.P. brass handle, unions and couplings for inlet,
outlet and overflow connections, and 40 mm dia
porcelain enameled flush bend for connection
between cistern and water closet, complete in all
respects as per direction of Engineer-in-Charge.
89 Providing and fixing brass wall mixer faucet for 8.00 No 2777.50
bathroom, wall mounted type, comprising hot and
cold water control with provision for overhead
shower / spout, including wall mixer body, bends, C.P.
flanges, necessary fittings and accessories, fixing
arrangement complete in all respects as per direction
of Engineer-in-Charge.
90 Providing and fixing screw down bib taps of following 20.00 No 186.83
size.(A) Brass screw down bib tap polished bright. (i)
91 Providing and fixing ball cock of approved. quality as 2.00 No 189.84
directed.(A) Copper Metal (ii) 50mm dia.
92 Providing and fixing washbasin with single hole for 12.00 No 2052.32
pillar tap with C.I. or M.S. brackets painted white
including sutting holes and making good the same
including Brass waste, and M I fisher union fittings
including pvc connection and waste pipe & all
necessary fittings For All Floor (A) Vitreous China:(ii)
Flat Back washbasin 550 mm x v 400mm size. (i) In
white colour
93 Providing and fixing 15 mm chrome plated brass 10.00 No 827.19
pillar cock, heavy duty type with swan neck, including
C.P. brass flange, necessary fittings, fixing
arrangement, complete in all respects as per direction
of Engineer-in-Charge.
Item Rate In
Description of Item Quantity Unit Amount
No figures
94 Providing and fixing 15 mm chrome plated brass 10.00 No 893.85
angle cock, including C.P. brass wall flange, necessary
fittings, fixing arrangement complete in all respects as
per direction of Engineer-in-Charge.
95 Providing and fixing C.P. brass shower rose with 8.00 No 282.16
15mm or 20mm inlet.(A) 100mm dia. Each
96 Providing and fixing 600mm x 450mm bevelled edge 8.00 No 851.13
mirrror of superior glass mounted on 6mm thick A.C.
sheet or plywood sheet and fixing to wooden pluge
with C.P. brass screws and washers.
97 Providing and fixing C.P. brass towel rail comlete with 12.00 No 616.42
C.P. brass brackets fixed to wooden plugs with C.P.
brass scews.(B) 600mm x 20mm size.
98 Providing and fixing C.P. brass towel ring of approved 8.00 No 722.15
quality and size, with C.P. brass brackets fixed to
wooden cleats with C.P. brass screws, or with
concealed fittings as per manufacturer's design,
including drilling holes and making good the walls, all
complete as per the direction of the Engineer-in-
99 Providing and fixing 304 grade Stainless Steel tension- 52.00 Rmt 151.50
mounted curtain rod (drill-free installation type),
with high-strength internal spring mechanism,
adjustable length for easy customization, and rust-
resistant finish, as directed by the Engineer-in-
100 Providing and fixing screw down bib taps of following 20.00 No 214.81
size.(A) Brass screw down bib tap polished bright. (ii)
101 Providing and fixing pillar tap, capstan head, screw 12.00 No 354.69
down high pressure with screws, shanks and back
nuts. (ii) 20mm dia.
102 Providing and fixing chromium plated brass half trun 8.00 No 263.77
flush cock of approved quality including fixing in pipe
line etc. complete.(ii) 25mm dia.
103 Providing laying (to level or slopes) and jointing 196.00 Rmt 678.01
reinforced concrete Light duty non-pressure pipes I.S.
class NP2 of the following internal diameter with
collars and butt ends prepared for collar joints
including testing of joints complete. (D)
104 Providing and laying (two level or slopes) and jointing 150.00 Rmt 526.46
with stiff mixture of Cement Mortar in proportion 1:1,
Salt glazed stone ware pipes of pipes 150mm laying
lime concrete 1:2:4 (1-Lime putty :2-Fine samd : 4-
Graded brick aggregates 40mm nominal size) bedding
for stoneware pipes of following internal diameters
with necessary formwork and curing complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
105 Providing and fixing S.W. gully trap with C.I. grating 6.00 No 1246.92
brick masonry chamber and water tight C.I. cover
with frame of 300mm x 300mm size (inside) with
standard weight (i) Square mouth traps (B) 150mm x
100mm size P or R type
106 Constructing brick masonry chamber for 20.00 No 3223.92
underground C.I. Inspection chamber and bends with
briocks having croshing strength not less than 35Kg.
Cm2 in C.M. 1:5 precast RCC cover 455mm x 610mm
intenal dimensions with frame (R.C.C. top slabe with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10
inside plaster 15mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on
walls and bed concrete etc. complete (i) Inside
dimensions 455mmx 610mm and 450mm deep for
single pipe line.
107 Constructing brick masonry chamber for 11.00 No 3933.95
underground C.I. Inspection C.I. Inspection chamber
and bends with briocks having croshing strength not
less than 35Kg. Cm2 in C.M. 1:5 precast RCC cover
500mmx 700mm intenal dimensions with frame
(R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse
sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick
with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete
etc. complete (i) Inside dimensions 500mmx 700mm
and 450mm deep for single pipe line.
Extra over items for every additional depth of 0.1M. of
part thereof beyond 450mm depth for Brick masonry
chamber.(i) for 455mm x 610mm size.
Extra over items for every additional depth of 0.1M. of
part thereof beyond 450mm depth for Brick masonry
chamber.(i) for 500mm x 700mm size.
110 Providing and fixing GI Ladder of required pattern 300.00 Kg 95.95
with GI flats(30x3mm) or round or square bars
(12mm) at required spacing & with round headed
bolts and nuts or screws or welding including primer
coat of approved quality and two coats of oil paintas
as directed by engineer in charge
Item Rate In
Description of Item Quantity Unit Amount
No figures
111 Constructing kitchen Platform of 18 mm thick 12.00 Sqmt 4193.52
Polished Black Granite at top and 25 mm thick Kota
stone slab one side polished at bottom with
cementing Materials / adhsives including makeing
necessary grooves in walls with Vertical sandwich
two Kotastone 25 mm support every 60 cm centre to
centre or as required including all labour material of
approved quality incl. full moulded round front edge
granite strip of one side polished and jointed with
grey cement slurry including rubbing and polishing
etc. complete for all floors
112 Providing and fixing 25 mm thick polished kota stone 52.00 Sqmt 667.61
Shalve with full round edge and double side polished
of any required and fixing with cement slurry &
adhesive including both exposed edges cut and
Smooth Finished as directed by engineering in charge
etc. complete.
113 Providing and fixing Kitchen sink with C.I. or M.S. 4.00 No 9431.38
brackets, painted white including cutting holes in
walls and making good the same but excluding
fittings. SS Kitchen Sink (113B), Bowl Size:
114 Providing, and fixing modular kitchen base unit below 13.00 Sqmt 7397.24
platform , comprising 6 nos drawers of size approx.
0.80 m width × 0.25 m height each with 19 mm BWP
plywood sides, front and back, 8 mm plywood bottom,
finished with 1 mm laminate on front and inside,
fitted with soft-close telescopic channels, shutters of
size approx. 0.45 m width × 0.75 m height with 19 mm
BWP plywood, 1 mm laminate on both sides, SS
handles, including all internal laminated surfaces,
partitions, hardware, screws, and fixing complete as
per Engineer-in charge
115 Providing and fixing in position 300 mm high, 150 30.00 No 707.00
mm wide English letters made from 1.0 mm thick
stainless steel sheet as directed by Engineer in charge
with all necessary tools & plants etc. complete.
116 Providing and fixing in position 150 mm high, English 20.00 No 404.00
letters made from 1.0 mm thick stainless steel sheet
as directed by Engineer in charge with all necessary
tools & plants etc. complete.
117 Providing and fixing MS Box (75 mm x 50mm x 3mm) 34.00 Sqm 1848.30
with clear spacing 100 mm including fixed on wall.
Box should be Powder Coated will be fitted in
position including accessories as per requirement as
directed by Engineer-in-charge etc. complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
118 Providing and fixing temporary barricading made of 55.00 Rmt 3510.27
M.S. hollow steel sections for vertical posts and
horizontal runners, using MS square/rectangular
hollow sections of required size (minimum 32x32x2.6
mm or equivalent) spaced at suitable intervals, fixed
firmly in ground by excavation and embedded in PCC
1:3:6 (1 cement: 3 coarse sand: 6 graded stone
aggregate 20mm nominal size) . Horizontal and
vertical frames shall be securely fixed using
mechanical fasteners or welding as required.
Barricading shall be covered (0.50 mm thick) G.I.
sheet fixed with self-drilling screws with washers at
regular spacing. Top edge of GI sheet to be stiffened
with MS angle or pipe section to avoid deformation.
Work includes excavation,Pcc scaffolding/support for
stability, materials, labour, transportation, tools &
tackles, and complete installation as per drawings and
directions of Engineer-in-Charge.
119 Providing and fixing to wall ceiling and floor 10.0 Kg. 116.00 Rmt 339.05
F/Cm2 working pressure poluthene pipes of the
following outside Dia. Low densidy, complete with
special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and
floor.(G)110 mm
120 Providing and fixing to wall ceiling and floor 10.0 Kg. 100.00 Rmt 696.90
F/Cm2 working pressure poluthene pipes of the
following outside Dia. Low densidy, complete with
special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and
floor.(G)160 mm
121 Providing junction for rain water juncton chamber of 6.00 No 9102.12
size 0.60x0.60x0.75m with excavation of size
1.96x1.96 m & 0.15m thick c.c.1:2:4 bed concrete
including brick masonary wall in CM 1:6 of 0.75m
height & 0.23m thick with 15mm thick cement plaster
inside & outside & 1.06x1.06 RCC (1:2:4) slab of
thickness 0.15m with CRS steel and 0.60mx0.45m cast
iron manhole cover with frame weight not less than
35 kg as per directed by Engineer-in-charge
122 Providing Filter chamber of Brick work in C:M 1:6 of 1.00 No 16583.19
size 2.06mx1.20m x1.20m & excavation dimension of
2.66mx 1.81x1.35m including C.C 1:2:4 bed concrete
of 0.15m thick including brick work in c.m 1:6 for
23cm thick wall including 15mm thick cement plaster
inside & outside with cement slurry & 10cm thick RCC
1:2:4 top cover with frame of minimum weight of
kg & filling filter material kapchi in layers (25-40mm
& 10-20mm) & BT metal 40mm & sand as per
directed by Engineer-in-charge
Item Rate In
Description of Item Quantity Unit Amount
No figures
123 Providing Recharging pit of size 2.0m Dia. & 5.0m 1.00 No 15474.21
depth of water logging with excavation filling the pit
with gravel & sand in layers including making 300mm
dia bore depth of 5.0 mt & above concrete with kapchi
in layers (20-40mm & 10-20mm) & BT metal 40mm &
filling brick as directed by Engineer-in-charge.
124 Drilling of min. 250 mm dia. bore hole in all strata 100.00 Rmt 1270.58
including dualover burden strata by combination
DR/DTH rig including lowering 200 mm dia MS ERW
pipes in bore hole and testing etc.all work as per
directed engineer incharge.
125 Manufacture, supply and delivery of cage 70.00 Rmt 2001.82
typeTrapezoidal shape ( ' V ') wire wound low carbon,
Galvanized screen pipe and Stainless Steel Screen
pipes, confirming IS: 8110 For (B) 200mm dia 1)
1.00mm Slot size
126 Bore plug having 100 mm height made from M.S. plate 1.00 No 1161.62
with 3 holes at equal distance on circumference for
nut-bolts type, locking arrangement with nuts-bolts &
lock nuts of std. Make complete. For 250mm dia
127 Providing PVC insulated flat submersible cable as per 120.00 Rmt 121.20
detailed technical specifications of R/C of GWSSB
conforming to IS 694, IEC 60227 / 60228.d)1 R x 3 C x
128 Suppling and installing 3 Phase Borewell 15.00 HP 1.00 No 169091.17
Submersible Pump Sets Electric motor driven
conforming to I.S. 8034 and motor conforms to IS-
9283 working at 3 phase 400/440 volt 50 C/S A.C.
supply & 2900 R.P.M. cat
129 Providing and fixing check or non return pully wheel 1.00 No 1111.00
valve of 50 mm diameter.
130 Providing and fixing to wall,ceiliing and floor 120.00 Rmt 794.18
galvanised mild steel tubes ( Medium grade ) of the
following nominal bore, tube, fittings and clamps
included making good the wall, ceilling and floor (F)
Item Rate In
Description of Item Quantity Unit Amount
No figures
131 Constructing brick masonry chamber for 5.00 No. 7180.44
underground C.I. Inspection chamber and bends with
briocks having croshing strength not less than 35Kg.
Cm2 in C.M. 1:5 C.I. cover with frame (Light duty)
455mm x 610mm intenal dimensions, total weight of
cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-
graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating
coat of neat cement on walls and bed concrete etc.
complete.(iii) Inside dimensions 600mm x 850 mm
and 450mm deep for pipe lines with three or more
132 Box cutting the road surface to proper slope and 335.00 Cum. 106.81
camber for making a base for road work including
removing the excavated stuff and depositing on the
road side slope as directed upto upto All lift and lead..
133 Providing, laying and compacting natural sand & 51.00 Cum. 394.91
gravel[ C.B.R. not less than 20%] below sub base
course including carriage of materials spreading in
uniform layer manually on prepared base and
compacted with vibratory roller to achieve desired
density including all materials, labour etc. complete.
134 Construction of granular sub-base 150 mm thick by 110.00 Cum. 737.30
providing coarse graded machine crushed B.T.
material satisfying MOST specification of grading I
(B.T. stone aggregate 53 mm to 26.5 mm 35 %, 26.5 to
4.75 mm - 45 % and 2.36 mm below - 20 % )including
spreading in uniform layer with motor grader on
prepared surface, mixing by mix in place method with
rotavator at OMC and compacting with vibratory
roller to achieve the desired density etc. complete.
135 Providing and laying wet mix macadam base course 99.00 Cum. 1033.23
150-250 mm thick in two layers using machine
crushed B.T. chips as per required gradation mixing
with required optimum quantity of water, conveying
the mix to site of work, spreading in to grade and
camber with mechanical paver and consolidation each
layer with vibratory roller including cost of material
labour plant and equipment etc. complete.
136 Compaction and finishing of cement concrete road by 482.00 Sqm 63.63
trimix process providing extra Labour charges for the
trimix vacume dewatering service process on cement
concrete road sutface by using vacuum dewatering
pump floater surface vibrator including making
groves and rough finish to surface including leveling
etc complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
137 Providing and Laying homoginious Grey cement 214.00 Rmt 370.68
based concrete kerbing of size 30 cm x 30 cm x 10 cm
size as per detailed drawing having grade of concrete
M25 grade, including necessary excavation, BBCC
1:5:10 7.5 cm as per ddetailed drawing fixing in line
and level, filling joints in CM 1:3 with smooth finished,
white washing three coats etc. complete as directed
by Engineer in charge.
138 Supplying FIRE bucket round bottom of 9 litres 4.00 No 404.00
capacity made out of 24 gauge G.I Sheet with extra
handle at bottom duly painted white inside and Red
out side with FIRE mark. Filled with dry-sand and
kept on existing stand provided or hung on wall hook.
139 Supplying and erecting floor mounting Stand for 1.00 No 5050.00
keeping four nos. of FIRE buckets comprising
mm in length, 900 mm height frame made out of
30mm x 30 mm x 4 mm angle iron with cross suports
legs, welded with 4 hooks and duly painted with one
coat of red lead and two coats of approved enamelled
silver paint.
140 Supply, Filling and Fixing of following type of approve 4.00 No 5555.00
make fire Premium extinguishers CO2 type fire
extinguisher, Capacity 5.0 Kg. (conforming to IS-
141 Supply, Filling and Fixing of following type of approve 4.00 No 2525.00
make fire extinguishers Dry powder type, Capacity
Kg. (conforming to IS:2171 with cylinder fully
142 Design, supply & installation of Safety Signage made 3.38 sqmt 4595.50
of zinc sulphide based glow in the dark rigid sheet
with high luminous property enclosed in a
transparent weather proof U/V stabilized plastic
pasted on 3mm thick clear acrylic sheet such as EXIT,
EMERGENCY EXIT, CASE OF FIRE, FLOOR MARKINGS,
FIRE LIFT, STAIRCASE EXIT or any other Word etc
143 Clearing and grubbing road land including uprooting 0.30 Hectare 28455.09
rank vegetation grass bushes,shrubs,sapling and trees
girth up to 300 mm removal of stumps of trees cut
earlier and disposal of unserviceable materials (C) By
mechanical means in area of light jungle
144 Earthwork for embankment including breaking clods, 1439.00 Cum 165.25
dressing with all lead and lift (excluding watering and
consolidation)(E) From Borrow area within all lead
145 Rolling of earthwork in layers with power roller 1440.00 Cum 22.89
including filling in depressions which occur during
the process and Watering of earth work as directed.
Item Rate In
Description of Item Quantity Unit Amount
No figures
146 Providing and casting in situ controlled cement 14.00 Cum. 4785.19
concrete M-200 for Kerb/ kerb blocks including
formwork curing and finishing, complete
147 Supplying of well rotted FYM manure with all lead 20.00 Cum. 378.75
and Lift including spreading mixing dressing and
rolling with hand roller etc. complete.
148 Scarifying the surface of Soil including spreading of 765.00 Sqm 26.26
DAP fertilizer mixing with Soil properly levelling gand
dressing of the plot
149 Supplying and planting semi carpet lawn in Gunny 765.00 Sqm 121.42
Bag and Cost of labour And including maintanatce .As
per Eng-in charge
150 Supplying And Planting box hedge Shurbs of Average 15.00 No. 103.01
hight 1ft-2 ft By providing and mixing FYM 2@ rate of
0.06cmt/pit with soil pesticide & Insectiside Plant
should be deisease Free and fungs free in 6inchx
8inch polythene bag plastric bag or pots should be
remove carefully and soilt around the roots should
not be droped or distrub much bill shall be placed
after completions of maintanace period but not before
stablizing the shurbs.mortality rate to beinclusive .as
directed and approved by ECI. the ground coverage
should be dense and uniform throghout the planting
151 Supplying well Grown Shurbs Plants of Average hight 20.00 No. 101.99
3ft-4 ft and planting in 300x300x300mm size Pits By
Mixing Of FYM & Existing soil in ration 1:3 with soil
,Pesticide & insecticide .plants should be disease free
and fungus free in 8ftx10ft polythene bag plastric bag
or pots should be remove carefully and soilt around
the roots should not be droped or distrub much bill
shall be placed after completions of maintanace
period but not before stablizing the shurbs.mortality
rate to beinclusive .as directed and approved by ECI.
the ground coverage should be dense and uniform
throghout the planting area
152 Supplying well Grown Canna Bulb Plants of Average 15.00 No. 86.75
hight 1ft-2 ft and Providing in 2 row at 300mm/cc in
300x300x300mm size pits by Providing and Mixing
Of FYM @ 0.06cmt/pit with soil pesticide and
insecticide .plants should be disease free and fungus
free in 8ftx10ft polythene bag plastric bag or pots
should be remove carefully and soilt around the roots
should not be droped or distrub much bill shall be
placed after completions of maintanace period but not
before stablizing the shurbs.mortality rate to
beinclusive .as directed and approved by ECI. the
ground coverage should be dense and uniform
throghout the planting area
Item Rate In
Description of Item Quantity Unit Amount
No figures
153 Providing and planting of Khengar tree plants healthy 15.00 No. 961.70
and well-grown, of height not less than 3 ft, in
polybags or earthen pots, including excavation of pit
of required size, arrangement and placing of rubble at
bottom for proper drainage, refilling the pit with good
quality garden soil mixed with FYM, watering,
application of organic and chemical fertilizers,
pesticides, all complete including cost of labour,
materials, and as per direction of Engineer-in-
154 Bowing and developing flowering plants grown in 8.00 No. 10.10
nusery having approximate height 4 to 5 ft or Height
ad per Landscaps Plan with natural growith and
nature colour planted in alump of soil packed in
polithyline bag or Earthern pot. Including organic &
chemical fertilizer pesticides, fungicides hormones &
maintaining the plants uo to three months as deserted
green mahindi
155 Bowing and developing flowering plants grown in 5.00 No. 15.15
nusery having approximate height 4 to 5 ft or Height
ad per Landscaps Plan with natural growith and
nature colour planted in alump of soil packed in
polithyline bag or Earthern pot. Including organic &
chemical fertilizer pesticides, fungicides hormones &
maintaining the plants uo to three months as deserted
New block ficus.
156 Labour charges for planting various plantsafter 78.00 No. 40.40
proper anti termite treatment in pits including placing
property and filling the pit with requred prepared mix
soil and wetering and dispporting etc complete.
157 Maintance of the garder for 360 days after Complition 1.00 Job. 10100.00
of 3 month stipulated period is completed for
plantation o lawn and plants including applying
second round of proper antitermite tretment.
158 Providnig and fixing to wall ceiling and floor 80 100.00 Rmt 447.72
Schedule Syntex / Astra (CPCV) or equivalent of the
following nominal bore tube fittings and clamps the
wall ceiling and floor (C) 40 mm
159 Providing and fixing consealed to wall, ceiling and 90.00 Rmt 208.80
floor 80 Schedule Syntex / Astral (CPVC) or
equivalent brand of the following nominal bore tube
fittings and clamps including Making goods the wall
ceilling and floor (A) 20 mm
160 Providing and fixing brass screw doen stop cock (A) 1.00 Rmt 287.85
15 mm. Dia.
161 Rubber Hose pipe 15 mm dia of approved brand and 120.00 Rmt 25.25
162 Providnig and fixing G I Nipple as directed. 1.00 No. 20.20
Item Rate In
Description of Item Quantity Unit Amount
No figures
163 Providing and fixing LLDPE and Plastic Kids Outdoor 1.00 Nos 480255.00
Slide Set of size 35" × 19" × 14" (inch), made of high-
quality rotational molded LLDPE and durable plastic
material, suitable for children play in parks, gardens,
schools and residential areas. The slide set shall be
Brand: KHELOKUDOO, designed with smooth edges,
child-safe finish, UV-stabilized and weather-resistant
material. Including all necessary accessories,
supports, fasteners, anchoring arrangements and
fixing complete in all respects as per manufacturer’s
specifications and directions of Engineer-in-Charge.
164 Point wiring for Light / Bell with 2-1.5 sq.mm & 84.00 Pt. 485.81
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push
& accessories and earth continuity of following type,
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector
as directed. (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat.III
165 Point wiring for Light / Bell with 2-1.5 sq.mm & 18.00 Pt. 242.91
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push
& accessories and earth continuity of following type,
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector
as directed. (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete W/C Point Cat. III
Item Rate In
Description of Item Quantity Unit Amount
No figures
166 Point wiring for FAN with 2-1.5 sq.mm & earth wire 21.00 Pt. 674.68
of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step
type electronic fan regulator mounted and
accessories with earth continuity of following type
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed. (f)
with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat.III
167 Point wiring for on board Looped Plug with 6A 29.00 Pt. 257.55
Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories Cat. III
168 Providing following type of Modular Type Accessories 25.00 Ea. 151.50
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (1)One No. SP 6 Amp. Cat.III
169 Providing following type of Modular Type Accessories 25.00 Ea. 151.50
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (2) One No 5 pin plug Cat.III
170 Providing following type of Modular Type Accessories 4.00 Ea. 160.59
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (4) TV Co-axial Socket outlet
171 Providing following type of Modular Type Accessories 36.00 Ea. 25.25
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (7) Blank Plate Single Cat.III
Item Rate In
Description of Item Quantity Unit Amount
No figures
172 Providing following type of Modular Type Accessories 21.00 Ea. 180.79
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (9) 16 Amp. SP one way switch
173 Providing following type of Modular Type Accessories 29.00 Ea. 199.98
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (10) 6/16Amp. Universal
socket Cat.III
174 Providing following type of Modular Type Accessories 8.00 Ea. 410.06
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (14) 6A/ 10A/ 16A/ 20A/
25A/ 32A Double Pole Modular MCB Switch
175 Providing and erecting ISI mark Medium class RIGID 160.00 Mtr. 33.33
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed (b) 25 mm
176 Providing and erecting Mains with 1.1 KV grade FRLS 1440.00 Mtr. 82.82
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed
in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) With
medium class Rigid PVC pipe and accessories (b)
wire 2.5 sq. mm
177 providing and erecting Mains with 1.1 KV grade FRLS 700.00 Mtr. 112.11
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on
wall / ceiling with 2.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for earth
continuity of following size (A) with medium class
Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
178 providing and erecting Mains with 1.1 KV grade FRLS 180.00 Mtr. 147.46
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on
wall / ceiling with 2.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for earth
continuity of following size (A) with medium class
Rigid PVC pipe and accessories (b) 2 wire 6 sq. mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
179 providing and erecting Mains with ISI marked, 1.5KV 39.00 Mtr. 56.56
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (e) One wire 6.00 sq. mm
180 providing and erecting Mains with ISI marked, 1.5KV 21.00 Mtr. 91.91
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (f) One wire 10.00 sq. mm
181 Supplying and erecting Flexible PVC insulated multi 100.00 Mtr. 46.46
strand multi core 1.1 kv grade ISI marked copper
wires of following size to be erected as directed. (e)
1.50 Sq.mm 3 core round PVC sheathed
182 Providing & Erecting approved make following size of 200.00 Mtr. 39.39
TV Co-axial flexible cable comprising inner conductor
of solid bare copper insulated with Foam PE &
Secondary conductor made of poly - Aluminium film
bonded Al. Braids @ suitable coverage overall
sheathed with black PVC insulation. (b) RG-6
183 Supplying & erecting approved make LAN cable of 200.00 Mtr. 47.47
following size in existing pipe as per direction [C] CAT
184 Decorative call bell Ting-tong box type 250 volts 4.00 Ea. 71.71
complete erected
185 Supplying and erecting LED indoor fittings with LEDs 59.00 Ea. 535.30
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor
more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
shown.) (A) Tube Light with integral driver (v) 36-40
Watts, Surge-2 KV, IP-20, conventional 4 feet Cat.III
Item Rate In
Description of Item Quantity Unit Amount
No figures
186 Supplying and erecting led lamps with following 34.00 Ea. 112.11
wattage capacity of 220 to 240 voltage, minimum
15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable
for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED
Lamps integral type, with PC diffuser suitable LAMP
holder (ii) 5 to 8 watts Cat.III
187 Supplying and erecting LED street light / Flood light 24.00 Ea. 4997.48
fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with
smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company
mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
between the ranges shown.) (A) Street Light (IP-65),
Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (ii)
above 48 to 60 Watts Cat.III
188 Providing and erecting Approved make Four pole 2.00 Ea. 6173.12
moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V,having normal current
rating up to 25 A to 100A. with Fixed thermal &
magnetic release suitable to work on A.C. supply
c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
189 Providing and erecting Approved make Four pole 2.00 Ea. 8055.76
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having normal current
rating 125A. with Fixed thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. ICS=100% of
ICU only Cat III
190 Providing and erecting Approved make Earth fault 3.00 Ea. 4983.34
Relay suitable to mount with inter connection suitable
to following size of moulded case circuit breaker
having CT ratio & MCCB rating as following along
with shunt trip 220V AC. with all internal connections
& complete erected in existing M.S.housing.. (2)
A -200 A , CT Ratio 1/200
Item Rate In
Description of Item Quantity Unit Amount
No figures
191 Supplying and erecting triple pole & neutral 440V / 1.00 Rn.Mtr 1961.42
500V panel mounting Copper Busbars with four equal
Nos. of electrolyte bus having current density not
more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying
capacity, erected with necessary bus bar supports
/insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections.
(A) Suitable for 100 Amp. Capacity
192 Providing and erecting Miniature circuit breaker 22.00 Ea. 270.68
single pole 0.5A to 2A system and having breaking
capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark Cat.III
193 Providing and erecting Miniature circuit breaker 40.00 Ea. 112.11
single pole 6A to 25A suitable to operate on 240 V A.C.
system and having breaking capacity 10 KA to be
erected in existing box. confirming to IS 8828/1996
with ISI Mark Cat.III
194 Providing & erecting 240 V MCB double pole switch 2.00 Ea. 278.76
for lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (A) 6 to 32 Amp. Cat.III
195 Providing & erecting 240 V MCB double pole switch 7.00 Ea. 295.93
for lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. Cat.III
196 Providing & erecting 415 V MCB Four Pole for Motor 8.00 Ea. 668.62
& Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity (b)40 Amp. Cat.III
197 Providing & erecting 415 V MCB Four Pole for Motor 1.00 Ea. 737.30
& Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity (c)63 Amp. Cat.III
198 Sheets steel powder coated enclosure suitable for 12.00 Ea. 176.75
incorporating One/Two nos. MCB.
199 Providing and erecting Sheet Steel powder coated 5.00 Ea. 1680.64
MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
suitable for (A) single phase incoming and horizontal
single phase outgoing (b) sheet steel double door (IP-
Item Rate In
Description of Item Quantity Unit Amount
No figures
200 Providing and erecting Approved make RCCBs 8.00 Ea. 1969.50
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
having characteristic of quick action & tripping with
all advance feature & do not incorporate any
electronic component. for following Max. rating
erected as directed (i) 25 Amps.DP Cat. III
201 Providing and erecting Approved make RCCBs 9.00 Ea. 2235.13
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
having characteristic of quick action & tripping with
all advance feature & do not incorporate any
electronic component. for following Max. rating
erected as directed (ii) 40Amps. DP Cat. III
202 Providing and erecting HOT deep Galvanised iron 10.00 Kg. 77.77
strip wire 8 to 16 SWG.
203 Providing and erecting Pipe type earthing having 150 7.00 Ea. 368.65
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth
pit complete with necessary 8 SWG earth wire.
204 For using salt and charcoal / coke as required for pipe 7.00 Ea. 171.70
type earthing.
205 Supplying & erecting earth pit of minimum bore 6.00 Ea. 5760.03
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly
conductive compound with high charge dissipation
suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make
OEM has to submit test certificate including value of
earth resistance of installation duly stamped and
signed by agency and officer Incharge has to ensure
the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:-
ohm / meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound
should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
(b)For Electrical installation up to 11 KV in normal
Length of Pipe : 2.00 mtrs
Back filling Compound :1 no. Bag of 25 Kg.
Item Rate In
Description of Item Quantity Unit Amount
No figures
206 Providing & erecting weather proof, dust & vermin 2.00 Sq.Mtr 14902.55
proof, floor mounted front operated indoor type
cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge
made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories
supporting angles/ flats channel including cutting,
bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of
supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control
fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end
terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall
be painted with epoxy powder coating. (The rates
excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips,
meters, Fuses etc. The dimension shall be measured
excluding base beams) The panel shall be supplied
with following approved manufacturers with
following size. (B) The standard companies switch
gear shall be used and only manufacturers at CPRI
approved factory (i) with 350mm depth
207 Providing , erecting , fabricating the M.S. structure as 40.00 Kg. 77.77
per requirement on site incorporating proper size of
M.S. angles,square,round, flats, bars, channels,
sections complete with cutting, welding, grinding &
finishing duly painted with one coat of red oxide with
erection on site as per direction of engineer in charge
with necessary grouting, cementing, plastering &
finishing complete.
208 Providing and erecting XLPE(IS:7098)(I)-88 ISI 80.00 Mtr. 92.92
armoured cable Aluminium conductor for 1.1 KV. to
be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables. (B) 2 core
209 Providing and erecting XLPE(IS:7098)(I)-88 ISI 80.00 Mtr. 220.18
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (B)
3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
210 Providing and erecting XLPE(IS:7098)(I)-88 ISI 120.00 Mtr. 284.82
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (C)
3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Item Rate In
Description of Item Quantity Unit Amount
No figures
211 Providing and erecting XLPE (IS:7098)(I)-88 ISI 494.00 Mtr. 126.25
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (B) 4 core 6 Sq. mm
212 Providing and erecting XLPE (IS:7098)(I)-88 ISI 80.00 Mtr. 140.39
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (C) 4 core 10 Sq. mm
213 Making trench in soft soil of suitable width of 90 cm 530.00 Mtr. 55.55
deep for laying cable or locating the fault all over the
run and back filling the same and making the surface
as normal ground.
214 Providing & laying approved make Double walled 540.00 Mtr. 62.62
corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting accessories
of same material at required depth in existing trench
for laying of cable. below ground / road surface for
enclosing cable (A)50 mm outer dia
215 Providing and, fixing heavy duty flange type brass 172.00 Ea. 38.38
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables. (B) 2 to
4 core 6 Sq. mm
216 Providing and, fixing heavy duty flange type brass 4.00 Ea. 38.38
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables. (C) 2 to
4 core 10 Sq. mm
217 Providing and, fixing heavy duty flange type brass 6.00 Ea. 75.75
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
cables. (B) 3 & 1/2 core 35/50 Sq. mm
218 Solder less crimping type Aluminium lugs conforming 176.00 Ea. 6.06
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
219 Solder less crimping type Aluminium lugs conforming 16.00 Ea. 13.13
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (B) 10 Sq.mm
220 Solder less crimping type Aluminium lugs conforming 16.00 Ea. 20.20
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (D) 35/50 Sq.mm.
Item Rate In
Description of Item Quantity Unit Amount
No figures
221 Providing & erecting Approved make Power Saving 21.00 Ea. 1948.29
50 Watt Ceiling Fan with double ball bearing ISI mark
with Condenser 230 volt A.C. 50 Hz 1200 mm sweep
complete having 3blades with aluminium blades with
, canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in
222 Supplying and erecting 19 / 20 mm. nominal bore 21.00 Mtr. 108.07
Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation
without leakage and earthing.
223 Supplying & erecting fan hook box of 10 mm M.S. 21.00 Ea. 108.07
round bar bounded to the RCC bars up to 50mm
length each side and pierced through a 16 Gauge M.S.
box / Heavy Duty PVC box complete erected
concealed in Ceiling with necessary finishing.
224 Providing 2.5mm.thick laminated acrylic sheet to 21.00 Ea. 18.18
cover the fan hook or Fan box.
225 Supplying and erecting approved make Octagonal 14.00 Ea. 6874.06
pole made from HR sheet steel. The pole should be
made as per IS. and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box
consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable
foundation (Included) as per details given by
manufacturer considering site requirement. (C) 5 Mtr.
Long 70 mm Top X 130 mm bottom dia, 3 mm
thickness with 200mmX200mmX12mm base plate, 4-
M16 Bolts and 600mm long with necessary G.I. J Bolts
.Approx Pole weight 46 kg
226 Supplying & erecting approved make SMC press 8.00 Ea. 515.10
moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable
clamps& earth bolt of following size of box. (B)
250mm x 200mm x 100mm [deep]
Item Rate In
Description of Item Quantity Unit Amount
No figures
227 Supplying and erecting Street light pole bracket 6.00 Ea. 491.87
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class G.I. sleeve
tubing of approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of
0.5 mtr. Length with 110 deg.with vertical plane and
suitable welded stiffener reducer and nipple with
check nut complete painted with one coat.of Red
oxide / PU base primer and two coats of Aluminium /
PU paint. paint with following nos of arms. [A] Single
Arm bracket 0.5 Mtr
228 Supplying and erecting Street light pole bracket 4.00 Ea. 622.16
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class G.I. sleeve
tubing of approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of
0.5 mtr. Length with 110 deg.with vertical plane and
suitable welded stiffener reducer and nipple with
check nut complete painted with one coat.of Red
oxide / PU base primer and two coats of Aluminium /
PU paint. paint with following nos of arms. [B] Double
Arm Bracket 0.5 Mtr
229 Supplying and erecting B class galvanised iron pipe 10.00 Ea. 343.40
32 mm outside dia 45 cm long duly welded on 20 cm x
20 cm x 3 mm thick M.S. base plate, erected on wall or
corner for mounting street light luminaire with
necessary hardware materials duly painted.
230 Supplying and erecting approved make panel 1.00 Ea. 1275.63
mounting type Digital Voltmeter having 3 digits LED
display, 0 to 750 AC Volts range erected on existing
panel board with all connection, wiring etc .with
manufacturers calibration certificate.
231 Supplying and erecting approved make panel 1.00 Ea. 1558.43
mounting type Digital Ammeter having 3 digits LED
display, external CT operated, calibrated for 0 to
Amps suitable to operate on 500 Volt AC , erected on
existing panel board with all connection, wiring etc
.with manufacturers calibration certificate.
switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections.
233 Supplying and erecting approved make suitable panel 3.00 Ea. 43.43
indicator LED type lamp, lens cover, complete erected
with necessary connections.
234 Providing & erecting L.T. Current Transformer with 3.00 Ea. 274.72
bar primary 50/5 to 1000/5 ratio 15 VA burden
erected in existing CRCA box duly secured with
insulating materials connected to the meter
Item Rate In
Description of Item Quantity Unit Amount
No figures
Total Rs.
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures
and words) of the estimated rate mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
The Credit Value of Dismentalled Materials of Amount Rs. 12050.00 shall be recovered from the 1st
Running Bill of the Contractor.
The Contractor shall exhibit a board with detailed specification and details of work as directed by the
2 Engineer-In-Charge for which no extra payment shall be made.
3 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
4 Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.:
PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C.
5 items where there is a change as per actual mix design the cost of difference of cement consumption
have been deducted from the rate of original item at the rate of input rate i.e. 6176/- per mt. mentioned
in all the tender.
Deputy Executive Engineer Executive Engineer
Navsari ( R & B ) Sub Division Navsari ( R & B ) Division
Navsari Navsari
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. SBD - D Type 4 Unit Navsari.pdf
1.1 GR.pdf
2. BOQ - D Type 4 Unit Navsari.pdf
3. Specification - D Type 4 Unit Navsari.pdf
4. Building-Specification Booklet.pdf
5. Special Condition Electric.pdf
6. Nominated Ele. Sub Contractors.pdf
7. Make List.pdf
8. Specification (Electrical Work).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .