Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹13.9 L+₹49,969 (3.72%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-AOC REJECTED |
Tender Value
₹16.2 L
EMD Value
₹32,400
Closing Date
21 Apr 2020, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR /MAINTANANCE OF INTERNAL ELECTRIFICATION, MAINTANANCE OF ACs, GEYSER AND WATER COOLER AT CG DHQ-1, CG JETTY AND CG AE PORBANDAR
2020_MES_324603_2
8486
Open Tender
Civil Works - Canal
Item Rate
180 days
DHQ No. 1, Coast Guard
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I CG Porbandar
₹32,400
Yes
15 May 2020
24 Mar 2020
22 Apr 2020
24 Mar 2020
21 Apr 2020
9 Apr 2020
Amount
SCHEDULE 'A'
Taking down carefully burnt out aluminium/copper wires from concealed point wiring without removing/ taking down conceled conduit and terminal boxes (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) and stacking materials properly for removing under schedule of credit and making good the disturbed surfaces of walls/ceilings and floors etc complete all as spd and directed. Note: (i) Existing MS sunken terminal and conduit boxes need not be removed. (ii) Cover plate of terminal box shall be removed.
Disconnecting of unserviceable sub main wiring of any size and removing wires from existing concealed conduit & removing from site and making good the disturbed surfaces. Note: (i) Existing concealed conduit boxes need be removed.
M&L point wiring complete with copper conductor 1.5 sqmm single core PVC insulated but unsheathed multistranded conductors FRLS, 1100 Volts grade, drawn through existing conduit including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with cover plate fixed on existing terminal boxes,complete all as specified and directed. Make of wire: Finolex/RR Cables/Havells/Anchor (a)One light point controlled by one, one way switch
(b)One fan point controlled by one, one way switch
(c)One bell point controlled by push button on the same board with other switches
(d) One 5 pin socket outlet 5/6 amps on the same board.
(e) One 5 pin socket oulet 5/6 amps on independent board..
M&L point wiring complete with copper conductor 2.5 sqmm single core PVC insulated but unsheathed multistranded conductors FRLS, 1100 Volts grade, drawn through existing conduit including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with cover plate fixed on existing terminal boxes,complete all as spd and directed. Make of wire: Finolex/RR Cables/Havells/Anchor
M&L point wiring complete with copper conductor 4 sqmm single core PVC insulated but unsheathed multistranded conductors FRLS, 1100 Volts grade, drawn through existing conduit including 4 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with cover plate fixed on existing terminal boxes,complete all as spd and directed. Make of wire: Finolex/RR Cables/Havells/Anchor
Supply and fixing in replacement of following items:- (a) Switch piano, flush type single pole, one way 5 Amp
(b) Socket outlet flush type 2 in 1, 5 pin, 5A
(c) Switch socket combination 2 in 1, 6 pin, 5 and 15 Amps flush type, universal
(d) Bell push, flush type, 5 amp
(e) Bell AC 230 Volt single pole multi music type .
(f) fan regulator flush & step type 120 watt, ISI marked
(g) Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body Note For Item No 7 (a) to (g) Make shall be e ANCHOR (Panta White)or equvalient/ Cona /Plaza
Supply and fix in replacement of following items (i) Modular switch 1 way 6A, 1module complete all as specified and as directed.
(ii) Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
(iii) Modular switch 1 way 16A, 1 module complete all as specified and as directed. .
(iv) Socket 6A/16A - 2/3 pin combined2 module,complete all as specified and as directed. For Item No 18 to 21 Make shall be ANCHOR (Roma) or equvalient/ Legrand/Leader
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in sotne/ concreate of slab in cement motor 1:4 complete all as spcified and as directed.
M&L sub main wiring with two single core 2.5 sq mm stranded copper conductor PVC insulated and unsheathed cable ISI marked in existing conduit concealed in wall/on surface of ceiling for sub main wiring alongwith including 2.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and directed
M&L sub main wiring with two single core 4 sq mm stranded copper conductor PVC insulated and unsheathed cable ISI marked in existing conduit concealed in wall/on surface of ceiling for sub main wiring alongwith including 4 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and directed
Supply and fix in repair of following DBs, double door type, single pole and neutral 240 Volt with standarad bus bar of following size enclosed in complete all as specified and as directed. a)KV Thermoplastic circuit breaker boxes IP-65 with knockouts for cable entry 1 row 4 modules box of size126 x 228 x111 mm with E + N terminals including with fixing accessories complete all as specified and as directed. Make model cat log No KV 7104 of Legrand/ Hager/Siemens
(b) KV Thermoplastic circuit braker boxes IP-65 with metric knockout for cable entry 1 row 9 modules box dimesnions size 202 x 238 x111 mm with E + N terminals ncluding with fixing accessories complete all as specified and as directed. Make catlog No KV 7109 of Legrand/ Hager/Siemens
(c) KV Thermoplastic circuit braker boxes IP-65 with metric knockout for cable entry 1 row 12 modules box dimesnions size 295 mm x 333 x129 mm with E + N terminals including with fixing accessories complete all as specified and as directed. Make model No KV 7109 of Legrand/ Hager/Siemens
Supply and fixing in repairs following MCBs (a) MCB SP 230 Volts, 6-32 Amps, 'C' series 10 KA complete all as specified and as directed. Make Legrand/ Siemens/Schinder
(b) MCB DP 230 Volts 40 Amps 'C' series 10 KA complete all as specified and as directed Make Legrand/ Siemens/Schinider
Comprehensive maintenance, including servicing and testing of Split type air conditioners of following capacity of any make complete for minimum service two times during the contract period of each unit by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing,compressor, greasing of blower motor, checking and removing any vibration testing after fixing at site all as directed. Note: (a) Cost of any minor nature repair / items such as nuts ,bolts,washers,screws,rubber mounting pads of compressor etc and labour required for removing / refixing including transportation of equipment to work shop and return (b) replacement of defective cooling coil, condenser fins, blower and blower motor, fan and fan motor, compressor, air filters, starting capacitors,PCB/ refrigerent charging etc as per requirment and cost of replacment of all these items is deemed to be included in unit rate quoted. (c) Replacment of outdoor/indoor unit if required shall be measeured and paid sepreatly.The decsion of requirment of replacement of inddor/outdoor unit shall be final and binding. (A) Split type AC more than 5 Yrs i)1.5 Ton
ii)2.0 Ton
(B)Split type AC with in 5 Yrs 1.5 Ton
Taking down for replacment of outdoor unit of split type AC and installing a new unit inclduing replacment of MS wall bracket,and replacment of refrigerent tubing inclduing charging with refrigerent, as per site requirment up to 6 mtrs with insulation connecting with indoor unit complete all as specified and as directed. (i) 1.5 Ton
(ii) 2.0 Ton
M & L charging of refrigerant gas (as per exsisting refrigerent) with appropriate quantity including testing for smooth functioning complete all as spd and as directed for following (fpr units other than under comprensive maintainence a)1.5 Ton Inverter AC / water coolers 40/ 80 ltr capacity / refrigerator (300 to 315 Ltr)
Repairs to Water Coolers Servicing of water cooler by cleaning the inner tank including disconnecting and reconnecting with plumbing line complete all as specified and as directed a) Water cooler 40/80 ltr capacity
Taking out burnt unserviceable condenser fan motor,and replacement with new electric motor,single phase 230V suitable for water cooler 40ltrs/hrs with condenser fan blade complete all as spd and as directed
M& L for repairs to body of water cooler in patches as per requirment by cutting and removing rusted sheet and providing new stainless steel sheet of grade 304 and as per the exsisting thickness, duly welded brazed including provision of hardware and remouting of compressor as per requirement complete all as directed
Supply and fix inreplacment of following items of water cooler (i) Thermostat for water cooler of capacity 40/80 ltr/hrs.
(ii) Bib tap Cast copper alloy 15 mm bore, Push type, chromium plated.
(iii) PVC Connection with brass unions at both ends
(iv) PVC Float valve with epoxy coated aluminium arm , with PVC polythene
(v) PVC drain out pipe 25 mm dia bore as per existing by providing necessary GI Clamps nuts bolts etc.
S& F in replacement compressor start relay suitable for any capacity of refrigerator complete all as spd and as directed Make -As per existing
S& F in replacement of condensor fan motor with fan suitable for refrigerator of capacity 180 to 310 ltrs including necessary capillary complete all as spd and as directed Make -As per existing
S& F in replacement of Temp control thermostate suitable for following capacity refrigerator including necessary capillary complete all as spd and as directed Make -As per existing (a) Refrigerator capacity 300 Ltr
(b) Refrigerator capacity 315 Ltr
(c) Refrigerator capacity 180 Ltr
Taking down fan, dismantling blades and removing fan/ hanging of ceiling fan/fixing of exhaust fan in situ all as spd and directed. (a) Ceiling Fan of size 1200 mm sweep
(b) Exhaust Fan of size 250/300 mm
(c) Exhaust Fan of size 450 mm sweep
(d) Wall mounted fan of size 300 mm sweep
Dismantling of motor of following items, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling all as spd and directed by Engineer-in-Charge. (a) Ceiling Fan 1200 mm sweep
(b)Exhaust Fan 250 / 310 mm sweep
(c)Exhaust Fan 450 mm sweep
(d)Wall mounted fan 300 mm sweep
(e) Air circulator 450 mm
Supply only spare parts of ceiling Fan of following rating all as spd and directed (a) Capacitor 2.5 MFD
(b) Capacitor 3.15 Mfd
(c)Ball Bearing No 6201
(d)Ball Bearing No 6202
(e)Supply and fix in replacement of unserviceable ‘U’ clamp with nut bolts, washers, split pins , rubbers bush of suitable length for hanging of ceiling fans complete all as required and specified and as directed.
Storage type water heater Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ all as spd and directed. Note- wornout parts shall be measured and paid seperately.
Supply & fixing in repair of following spare parts for storage type Gyser (a) Heating element 1.5 KW with rubber gasket .
(b) Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
(c) Hot/Cold water PVC connection pipe 450 mm length.
(d) Safety valve.
(e) 3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug top.
(f) Gyser assembly.
(g) LED indicator of suitable size
M&L for apply two coat of epoxy paint by sprayer on LT Panels including preparation of rusted surface of poles by means of sand paper/scrubing of dust etc and apply one coat of epoxy based primer before painting complete all as specified and directed.
S&F LED universal mounted 60 cm X 60 cm luminaire,240V, 50Hz, Nominal Lumen output 3000 lm, THD<20% ,PF>0.95Square in shape, complete all as specified and as directed by Engr-in-Charge, fixed in repair by replacing any type of fitting. Make: Smart Glow - Philips/ Lux Power - Osram/LM-25 Wipro
S&F Recessed mounted LED COB downlighter with high efficiency, housing made of extruded alluminium ,240V, 50Hz, 20W, CCT 4000 K, round in shape, complete all as specified and as directed by Engr-in-Charge, fixed in repair. Make:cat no: Wipro LD56 -251-060-40-XX/ or Equivalent from Philips / Bajaj Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
S&F Recessed mounted LED downlighter with high efficiency, housing made of extruded alluminium ,240V, 50Hz, 26 watt, CCT 5700 K, round in shape, complete all as specified and as directed by Engr-in-Charge, fixed in repair. Make:cat no: Wipro CRDL11RO17HP57*/ or Equivalent from Philips / Bajaj Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
S&F Recessed mounted LED downlighter with high efficiency, housing made of extruded alluminium with high trasluent HET diffuser ,240V, 50Hz, 17 watt, CCT 3000-6500 K, round in shape, complete all as specified and as directed by Engr-in-Charge, fixed in repair. Make:cat no: Wipro CRDL11RO33HP2765/ or Equivalent from Philips / Bajaj Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
Supply & fix LED Flood light luminaire 1x50W having IP-65 protection, with minimum system efficiency as> 80%,made of pressure die cast housing toughned glass with excellent thermal management. The fitting should have rate CCT 5000K complete with all accessories and complete all as specified and as directed, fixed in repair Make : Philips Cat no BVP 161 LED/43 NW/CW/WW 50W or Equivalent from Wipro / Bajaj
S&F LED recess mounted luminaire,240V, 50Hz, Nominal Lumen output 800 lm,6500K Square/round in shapecomplete all as specified and as directed by Engr-in-Charge, fixed in repair. Make: Philips (Green Perform) type DN 395 P /or Equivalent from Wipro / Bajaj Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate.
S&F LED recess mounted luminaire,240V, 50Hz, Nominal Lumen output 600 lm, CCT 6500K, Square/round in shape complete all as specified and as directed by Engr-in-Charge, in replacement. Make: Philips (Green perform Sleek type DN 295B or Equivalent from Wipro / Bajaj Note- cost of replacing in existing cut out of falce ceiling deemed to be included in unit rate
Supply and fix in replacement of aviation light Input Voltage : 172v-275vAC LED : 302+302 Current : 200ma Power Factor : 0.9 Body : Pressure Di Cast Aluminum complete all as specfied and as directed Make Bajaj 110731 BGAV 302 LED
M & L servicing and cleaning of solar water heater of 200Ltrs capacity including de-scaling and cleaning of cold/ Hot water tanks, complete all as directed.
M & L replacement of worn out insulation for hot water GI pipe of dia 15 mm from solar water heater system complete all as specified and as directed.
Supply & Fixing air release valve 20 mm dia of copper with operating handle complete all as specified and as directed.
M&L Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV complete all as specified and as directed by Engr-in-Charge. location as directed by EIC
S&F 19mm dia Rigid non-metallic PVC conduit inclusive of junction boxes (1 to 4 way), medium duty, including all Tees, bends, elbows, reducers, bell mouth tube ends, and fixing couplers, lock nuts, saddles, pipe hooks etc, fixed in repairs
OM ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .