Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC GAGAN DEEP APARTMENT 124 124 1 BANGUR AVENUE BLOCK C KOLKATA 700 055 | 24 PARAGANAS NORTH | WEST BENGAL | 700055 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.9 L+₹2.5 L (8.00%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹35.0 L+₹3.5 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹35.4 L+₹4.0 L (12.7%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹35.6 L+₹4.2 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹57,800
Closing Date
14 Jul 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
MISCELLANEOUS REPAIR WORKS TO FENCING, BOUNDARY WALL, DRAIN, HARD STANDING, COMPOUND WALL, PCC PATH ETC AT ZONE A AND PERIODICAL SERVICES TO MARRIED AND OTM ACCN TO VARIOUS BLDG AT ZONE A AND B AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_454481_1
8523/E8
Open Tender
Civil Works
Item Rate
210 days
Barrack pore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹57,800
Yes
13 Aug 2021
24 Jun 2021
16 Jul 2021
24 Jun 2021
14 Jul 2021
9 Jul 2021
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering etc complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground embedded in concrete, brick work, masonry etc complete all as specified and directed.
Removing plant including roots by dismantling of brick work/PCC/RCC including necessary scaffolding any type in any location/position i.e. roof, parapet wall near pipes etc and applying concentrated hydrochloric or sulphuric acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC (1:2:4) type B0 & 10mm thick plaster in cement mortar (1:3) size of disturbed portion 150mm X150mmX200mm complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as foundations, filling, and mass concrete for fencing post, pillars etc complete all as specified and directed.
M&L for PCC (1:2:4) type B2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate), as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for broken glass coping on top of walls in cement mortar (1:3) complete all as specified and directed.
M&L for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410 (Gde E-250) quality 'A' complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm but not exceeding 10cm long with shank 5 to 10mm dia complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10cm but not exceeding 15cm long with shank 5 to 10mm dia complete all as specified and directed.
S&F for angle iron works as in post and struts in fencing post including cutting tops to shape as directed, drilling holes, bolting or riveting, notching for wire etc conforming to Fe. 290 Gde E-165 complete all as specified and directed.
Supply only MS round bars 10mm dia for securing chain link fencing fixed to RCC fencing posts as per Fe-410-W (Gde- E-250) quality 'A' or Fe-290 (Gde E-165) complete all as spcrified and directed.
S&F for galvanised iron chain link fencing with 4 mm dia of wire made up into matresses with mesh of any size and type and fixed with 10 mm dia MS round bars and straining including provision of binding wire for securing chain link fencing after and including dismantling of old unserviceable chain link fencing of any type including round bars and nut & bolts etc as per relevant IS specification and as approved complete all as specified and directed. (Note: 10 mm dia MS round bar shall be measured and paid separately as supply only)
S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. after and including taking down old unserviceable galvanised steel barbed wire complete all as specified and directed (Each line of wire to be measured).
Restraining resecuring of old barbed wire including making good, staples or steel pins, securing or tying at crossings with and including of galvanised mild steel wire etc complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor / hard standingcomplete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in sub base of floor/chequred tile/paver block complete all as specified and directed.
M&L for 50mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in floor, hard standing etc finished the surface fair and even by brooming complete all as specified and directed.
M&L forming contraction joints (dummy) 50mm deep X10mm wide, filled with sealing compound of Grade 'A' complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) over in and including 50mm thick compacted sand cushioning after and including dismantling old paver block complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with WPC as per manufacturer's instructions , finished even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:6) in patches not exceeding 3 Sqm (each patch) on brick work or concrete surfaces, finished even and smooth without using extra cement on plastered surface complete all as specified and directed.
M&L for rendering 15mm thick in patches not exceeding 3sqm (each patch) with cement mortar (1:4) mixing with WPC as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 5mm thick in cement mortar (1:3) in patches not exceeding 3 Sqm (each patch) on brick work or concrete surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of wall after preparation of old plastered surfaces complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of ceiling after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying one coat of white wash on old decorated wall surfaces after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying one coat of white wash on old ceiling surfaces after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying one coat of colour wash including preparation of old decorated surfaces of walls, cornices etc complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for applying one coat of cement based paint on old plastered surface of walls after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on ceiling after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkiline resistant primer on newly plastered wall surfaces after preparation of surfaces complete all as specified and directed.
M&L for applying one coat of oil emulsion distemper over old distemper plaster surfaces of wall after preparation of surfaces complete all as specified and directed.
M&L for applying one coat of oil emulsion distemper over old decorated plaster surfaces of ceiling after preparation of surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description not exceeding 10 cm width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, not exceeding 10cm in width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wood or wood base surfaces of any description not exceeding 10cm in width or girth complete all as specified and directed.
M&L for one coat of synthetic enamel paint as in camouflage pattern as existing at site including preparation of old plastered surfaces of any description complete all as specified and directed.
M&L for applying two coats of acrylic exterior emulsion paint over one coat of acrylic primer on old decorated surfaces after complete removal of existing treatment including preparation of surfaces of wall, cornices by wire brushing, rubbing down complete all as specified and directed .
M&L for applying two coats of plastic emulsion paint over a coat of primer suitable plastic emulsion paint on old wall surfaces after complete removal of existing treatment including preparation of old surfaces complete all as specified and directed.
M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation of existing surfaces complete all as specified and directed.
PUNAM ENTERPRISE
MAZUMDER AND CO
KOLAY CONSTRUCTION
M/S PAUL CONSTRUCTION
NANDY ENTERPRISE
CHATTERJEE CONSTRUCTION AND SUPPLIERS
N. MUKHERJEE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .