Loading…
Loading…
Tender Value
₹3.4 L
EMD Value
₹8,385
Closing Date
14 Jul 2026, 6:00 pm7d left
Executive Engineer(Electrical)
University of Calicut
Replacement of damaged AUG cable for main motor and panel board at IET Campus
2026_UoC_858303_1
D3/170107/E-Tender No.5/2026-27 (Re1)
Open Tender
Electrical Works
40 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹826
₹8,385
3 Jul 2026
3 Jul 2026
17 Jul 2026
3 Jul 2026
14 Jul 2026
3 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 1.10.1
Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 FRLS PVC insulated copper conductor single core cable in surface / recessed medium class conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A | - | point | - | - |
| 2 | 1.11
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | - | point | - | - |
| 3 | 1.14.1
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire | - | metre | - | - |
| 4 | 1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm | - | metre | 1 | - |
| 5 | 1.17.32
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 x 6 sq. mm | - | metre | - | - |
| 6 | 1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm | - | metre | 1 | - |
| 7 | 1.24.2
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 amps switch | - | each | - | - |
| 8 | 2.10.1
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole | - | each | 1 | - |
| 9 | 2.10.4
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole | - | each | 1 | - |
| 10 | 2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | - | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
epaymentform.pdf
Additional Documents • 0.01 MB
makeofmaterials_LAN_Electrical_Solar.pdf
Additional Documents • 0.98 MB
NIT.pdf
Additional Documents • 0.27 MB
DECLARATION.pdf
Additional Documents • 0.14 MB
BOQ_1450961.xls
BOQ • 0.32 MB
Tender_doc_IET.pdf
Tender Documents • 2.64 MB
Download all tender documents and submit your bid