Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC H NO 107 A RAJENDRA NAGAR DIGARI KALAN JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹41.6 L+₹1.9 L (4.70%)Rejected-Finance PLOT NO 361 FLAT NO 06 FIRST FLOOR SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹42.2 L+₹2.4 L (6.14%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹44.1 L+₹4.3 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹44.5 L+₹4.7 L (11.9%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
SPL REPAIR TO SEWAGE LINE OF OFFRS MD ACCN FROM BLDG NO P 623 TO P 670 RIGHT SIDE OF GATE AND CERTAIN PLACES OF JCOS OR S MD ACCN AT HAMID BAGH AND OTHER SANCTIONED WOKS IN THE AREA OF AGE BR II UNDER GE ARMY CENTRAL JODHPUR (9136/E8)
2022_MES_549637_1
GE/J/A OF 2022-23 (9136/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹98,000
Yes
6 Oct 2022
3 Sept 2022
27 Sept 2022
3 Sept 2022
24 Sept 2022
17 Sept 2022
Amount
B/R WORKS
Excavating in trenches in any type of soil, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc not exc. 10 Sqm on plan and not exc 1.5 m in depth and getting out, complete all as specified and as directed.
All as per item No. 1.00 here-in-above, but depth exceeding 1.50 m but not exceeding 3.00 m, complete all as specified and as directed.
Returning filling in including spreading ,levelling,watering and well ramming in layers not exc 25cm thick, complete all as specified and as directed.
Removing excavated material at a level not exc 1.5 m above the starting point, complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately.
All as per item No. 7.00 here-in-above, but 200 mm bore pipe
Supply & laying jointing and testing 150mm bore reinforced cement concrete pipes class NP-2 laid and jointed in cement mortor 1:1 complete, with collars or socket/spigot type laid jointed and haunching at side in cement complete all as specified and directed.
All as per item No. 9.00 here-in-above, but 200 mm bore RCC pipe class NP-2, complete all as specified and as directed.
Precast cement concrete block masonry using PCC 1:3:6, type C-1 solid blocks and setting in cement mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on stone masonary surfaces , finished fair & even, mixing with water proofing compound without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in coping/ benching, DPC, pier caps, bed blocks, for hold fast etc., including mixing with WPC and necessary form work, complete all as specified and as directed by Engr-in-Charge. Note:- WPC shall be measured and paid separately.
S&F in replacement precast steel fibre reinforced concrete (SFRC) any colour, 75-100mm thick manhole cover with frames (ISI marked) of overall covered area not exceeding 3.00 Sqm with clear opening not less than 0.36 Sqm, any shape (round, square, rectangular etc;) provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks which are duly protected against corrosion laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required including cranking, bending & binding with MS wire (annealed ) not less than 0.9mm dia or securing with clips, as in stirrups, complete all as specified and as directed.
S&F rolled mild steel sections like angle, channel, flat, square etc as in framed work such as manhole cover, grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars barred iron doors; chowkhat, doors with MS sheet, ladders ;framed balusters walk ways railings framed work of water tanks and similar work conforming to Fe-290Gde E-165 complete all as specified & directed by Engineer-in-charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms , moulds , mitred/stopped ends etc. complete all as specified and as directed .
Demolition of old abondoned existing manholes any depth with debbris and making good to earth, complete all as specified and as directed.
Dismantling of cast iron of CI drain pipe/PVC (SWR) pipe jointed in cement mortor of size 110/100mm bore, complete all as specified and as directed.
Dismantling of cast iron of CI drain pipe / PVC (SWR) pipe jointed in cement mortor of size 75mm bore, complete all as specified and as directed.
S&F 100mm bore spun cast iron (soil waste and vent) pipes in any length with or without ears with cement joints laid in trenches, including cutting hole where required, complete all as specified and as directed.
S&F 75mm bore spun cast iron (soil waste and vent) pipes in any length with or without ears with cement joints laid in trenches, including cutting hole where required, complete all as specified and as directed.
S & F cast iron bends [any radius], diminishing pieces or tapers [larger bore measured] of 100mm bore, for cast Iron soil / waste / vent pipes, complete all as specified and as directed.
All as per item No. 24.00 here-in-above, but bends with ovall access door, complete all as specified and as directed.
All as per item No. 24.00 here-in-above, but size of pipe 75 mm bore, complete all as specified and as directed.
All as per item No. 24.00 here-in-above, but size of pipe 75 mm bore bends with ovall access door, complete all as specified and as directed.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & as directed.
M&L walling of random rubble, un-coursed ,well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
All as per item No. 29.00 here-in-before, but except stone, complete all as specified and as directed.
Extra over stone walling for hammer dressing to face granite or trap stones with maximum depression on face from a straight edge held against the dressed surface not exceeding 40mm and dressing face beds and joints as specified of random rubble walling un-coursed or brought upto courses complete all as specified and as directed .
M & L for PCC 1:3:6, type C-1 [using 20 mm graded crushed stone aggregate] in surface channels and drains including forming fair finished drain or channel using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150/200 mm bore of pipe complete all as specified and as directed.
Cleaning/taking out sludge/mud/silt from manhole and septic tanks of any size and capacity manually or mechanically including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed. Note :-Sludge/mud/silt shall be measured before taking out from manholes/septic tank.
Cutting and grubbing of bushes grass and tree surrounding sewage line and levelling of ground around the sewage line, finish the surface and removing the waste material to distance exc. 50m and n exc. 250m and clearing the site, complete all as specified and as directed.
M&L for Jodhpur stone slab, machine cut 4cm to 5cm thick, 25cm to 35cm wide , as in drain cover hoisted and set jointed and grouted in cm 1:3, complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L 50 mm thick PCC 1:3:6 type C -1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair wothout using of extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight complete all as specified and as directed.
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
M&L for hard core broken stone of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, water and rammed to a true surface, with 10-12 tonne power roller, complete all as specified and as directed by Engr-in-Charge.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
Preparation of new concrete surfaces and applying two coats of synthetic enamel paint over & including one coat primer, complete all as specified and as directed by Engr-in-Charge.
M&L for squared rubble walling Jodhpur type regular coursed well bonded, bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick rendering in CM 1:6 on stone masonry finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint of approved quality & tint, over & including one coat of chalk white, complete all as specified and as directed.
Preparing new plastered or unplastered surfaces and applying 2-3 mm thick wall care putty in two coats including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper on walls, complete all as specified and as directed. Note:- OBD shall be in one or more colours/ shades all as approved by GE.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate), as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
M&L sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed.
M &L for Framed work as in door or gates of angle ,MS hollow pipes, solid SQ sections Flat iron etc or other section with gusset plates, rails, braces etc complete with steel sheetingas required to br prepared for hanging or sliding with and including MS Channel as posts & hold fasts & suitable arrangements for locking etc complete all as specified & directed conforming to Fe 290.Gde E165, complete all as directed by Engr-in-charge.
M&L Prepainted galvalume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws, complete all as specified and as directed by Engr-in-Charge.
Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in ridge, valley gutters, hip etc., fixed with self tapping screws all as specified and as directed.
S&F aluminium snap grid frame work of 600 X 600 mm panel size for false ceiling with Aluminium "T" section of size 38 X 25 X 1.50 mm thick for main runners, 25 X 25 X 1.5 mm thick for cross runners and angle of size 25 X 25 X 1.50 mm thick along the walls suspended with and including 4 mm dia, galvanized mild steel wire as in suspenders of ceiling members fixed in proper position, including high pressure steam curved (HPSC) 4mm thick prepainted and designer type E-boards and fixed with screws on snap grid as per manufacturer's specifications, complete all as required at site complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and apply two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
S&F chequered cement concrete tiles with rubberised finish of size 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with no pigment, over & including 15 mm thick screed bed in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
S&F of PVC (SWR)125mm /110mm dia gully trap, setting and jointing with solvent cement complete all as specified and as directed.
Cleaning/taking out sludge/mud/silt from manhole of any size and capacity mechanically including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed.
Cleaning of blockage from sewage pipe line of 150 mm bore by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover, including testing & commissioning complete all as entire satisfaction of Engg.-in-charge.
E/M Work M&L point wiring using approved colour coding as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI marked, in and including (flame proof) stove enamelled steel conduit of 20mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) with 3 mm thick plastic laminated sheet (ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & unsheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and as directed.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and as directed.
M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 4.00 Sqmm and one run of 4.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in stove enamelled steel conduit (flame proof) , (ISI marked) surface mounted/concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 4.00 sqmm cable with one run of 4.00 sqmm cable as earth wire and one run of steel conduit shall be measured & paid for as one length.
S&F Prewired distribution board (sheet metal enclosures) with suitable rated 200 Amps bus bar for Double door IP-43 DB's of apporved gauge conforming to IS relevant, SPN 4 way, 240 volt complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron earth lead wire of size 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
S&F in replacement, MCB SPN 240 volts rating from 10 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, including taking down old u/s material, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F in replacement, MCB SPN 240 volts rating from 5 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, including taking down old u/s material, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F detectors complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence as per IS:11360, complete all as specifed and dierected by Engg.-in-charge
S&F fire alarm sounders / sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db measured at 1.5 m with sound output variation of +5 db with 500 m range, complete all as specifed and dierected by Engg.-in-charge
S&F addressable manual call point break glass type with alarm LED , complete all as specifed and dierected by Engg.-in-charge
NOTE:- (i)- Quantities are clubbed in BOQ for different Jobs. For which ref. Annexure-I on Sl. page. No. 27 (R) to 28 (R) of tender document. (ii)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
M/s Ajay kumar Garge
m/s Firoz khan
M/S IK CONSTRUCTION
JB INFRA
Mahesh Dave
M/S KAUTILYA GARG
Bhawna Emporium
Bhairav Infra Projects
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .