Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹39.7 L+₹33,216.13 (0.84%)Rejected-Finance MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹42.1 L+₹2.7 L (6.80%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹42.1 L+₹2.7 L (6.93%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹42.9 L+₹3.5 L (8.86%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
7 Jan 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
PROVISION OF DRAIN AND TOILETS AT SHOPPING COMPLEX AND IMPROVEMENT TO CERTAIN SMQs AND OMQs AT DARJIPURA AT AF STN BARODA
2022_MES_562144_2
8752/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹79,000
Yes
11 Feb 2023
17 Dec 2022
9 Jan 2023
17 Dec 2022
7 Jan 2023
26 Dec 2022
Amount
Taking down chowkats or frame exc 1.5 Sqm and n exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and directed
Taking down chowkats or frame n exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and directed
Taking down shutter only of any description n exc 1 Sqm each complete all as specified and directed
Taking down shutter only of any description exc 1Sqm n. exc 2 Sqm each complete all as specified and directed
S&F Powder coated aluminium work for door, windows and ventilators and partition wall with one or more rebates fixed in position as per manufacturer's instruction including necessary joining cleat, glazing clips, rubber packing, beading ,plaster work on edges during fixing (if required)etc complete all as specified and directed.
S&F 4mm thick Sheet glass, ordinary quality and glazing with glazing clip and powder coated aluminium beading in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F Stainless steel wire cloth 0.36mm nominal dia wire and average width of aperture 1.14mm and fixed with powder coated aluminium beading/wood beading complete all as specified and directed
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) rubbish off the premises complete all as specified and directed
M&L for vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match premium quality as in floor etc. complete all as specified and directed
Description all as per item No 9.00 above but on vertical surfaces/skirting.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 SQM but not exceeding 0.11 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
M&L for Glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
M&L for 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 to receive tiles etc on vertical surfaces of walls complete all as specified and directed
Demolition of stone slabs and tiles of any description, laid bedded and pointed in any mortar complete all as specified and directed
M&L 20mm thick granite slab with fully rounded edges on front face fixed with adhesive or laid in neat cement slurry over and incl 15mm thick screed bed in CM 1:6 including cutting space for sink & gas pipe hole complete all as specified and directed
Taking dawn cement plaster any description on brick or stone wall/ celling including raking out joint , haking for key scrubing with water etc. complete all as specified and directed
M & L for 10 mm thick rendering in CM 1:6 on concrete surfaces / fair faces of brick masonary wall, finished even and smooth without using extra cement complete all as specified and directed
M & L for 15 mm thick rendering in two layer 10mm thick backing coat in CM 1:6 and finishing coat 5mm in CM 1:4 using water proofing compound on faces of brick masonary wall, finished even and smooth without using extra cement complete all as specified and directed Note: WPC will be measured and paid seperately under respective item.
M&L rendering 5mm thick on concrete surface of ceiling in CM 1:3 finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L Preparation of New plastered Surface of wall and application of two coats of Exterior Emulsion Paint over one Coat Primer complete all as specified and directed
M&L for preparation of New surfaces of wall and applying two coat of oil bound distemper (any tint shade as approved by GE) over application of chalk whitening complete all as specified and directed
Preaparation of new plastered ceiling surface and applying three coats of white wash complete all as specified and directed
Complete removal of existing treatment and apply TWO coat of Exterior acrylic Emulsion over a coat of primer incl preparation of surface complete all as specified and directed
M&L for Complete removal of existing treatment and applying two coat of oil bound distemper (any tint shade as approved by GE) over application of chalk whitening complete all as specified and directed
M&L preparation of old surfaces and apply 3mm thick JK/Birla Cement putty on wall/ceiling finished complete all as specified and directed
M&L for Complete removal of existing treatment and applying three coat of white wash complete all as specified and directed
Description all as per item No 27.00 above but three coat of white wash on ceiling surface complete all as specified and directed.
M&L filling surface cracks not exc 5 mm to 7 mm wide with "Dr fixit" cracks X power or equivalent polymer molified cracks filler all as per manufacturer instructions complete all as specified and directed
M&L 30mm thick 2nd class hardwood glazed and skeleton shutter open rebeted and prepared to receive glass gauze etc (without shash bar ) edges of framing plain chamfered or rounded filled with cut and mitered beads for securing, glass etc size of member of shutter as specified in SSR Part-I section 8,clause 8.24 (a) supplyed and fitted to chowkats complete all as specified and directed
M&L Factory made flush shutters 30mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides as in shutter complete all as specified and directed
M&L Factory made flush shutters 25mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides as in CB shutter complete all as specified and directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications & drawings complete all as specified and directed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings complete all as specified and directed
S&F 75mm long SS butt hinges and fixed to frame with scrwewd or welding complete all as specified and directed
S&F 200mm long aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and directed
Description all as per item No 36.00 above but 150mm long complete all as specified and directed
S&F aluminium alloy anodized sliding door bolt with hasp and staple (bolt type) and fixing clip of sheet cast or extruted section or cast aluminium alloy and fixed length of bolt 300mm complete all as specified and directed
S&F for 150mm long aluminium handle cast type anodized complete all as specified and directed
S&F Hasp and staple,safety type aluminium anodized including bolt to hinge plate and fixed with screws 150 mm size complete all as specified and directed.
S&F door stopper of 150 mm size (ISI Marked) aluminum alloy body and tongue double legged anodized with hard drawn steel spring over all length of cover plate fixed in floor complete all as specified and directed.
M&L Preparation of new wooden surface of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed
S&F 25 mm dia curtain drapery rod decorative type cut to length and fixed complete all as specified and directed.
S&F bracket suitable for 25mm dia curtain rod with steel screw/ wooden screw complete all as specified and directed.
Taking up or down steel tubing pipe and connections 15mm bore complete all as specified and directed
Taking up or down steel tubing pipe and connections 20mm bore complete all as specified and directed
S&F 15mm dia tubes ‘Medium grade’ galvanized with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed
Description all as per item No 47.00 above but fixing only 15mm GI tubing complete all as specified and directed
S&F 20mm dia tubes ‘Medium grade’ galvanized with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed
Description all as per item No 49.00 above but fixing only 20mm GI tubing complete all as specified and directed
Dismantling water tanks n exc 500ltr capacity complete all as specified and directed
S&F 500 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted complete all as specified and directed
S&F 20 mm ball brass valves,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed
S & F in repair vitreous china wash hand basin, flat back, size 450x300mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed
S&F in repair vitreous china pedestal pattern white (excluding fixing both flushing cistern and flush pipe) complete all as specified and directed.
Supply & fixing in repair plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated hinged device complete all as specified and directed
S&F in repairs 10 litres capacity PVC valveless symphonic action type, flushing cistern, low level, white, with inlet, ball valve float handle including brackets complete all as specified and directed
S&F 32mm brass chromium plated waste coupling for wash hand basin complete all as specified and directed
S&F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed to 15mm bore pipe complete all as specified and directed
S & F in repairs Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe. complete all as specified and directed
S&F in repairs Stop valves, cast copper alloy,screwed down, high pressure,with crutch or butterfly handle, screwed bothends for iron pipe or for runions and fixed to 15mm bore pipe complete all as specified and directed
S&F in repairs 32/40mm PVC waste pipe for wash hand basin., 600mm long complete all as specified and directed
S&F PVC connection 15mm size of 60cm long with PTMT nuts complete all as specified and directed
S&F Towel Rail 600mm long CP fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed
S & F Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed
Demolition of Concrete any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for providing cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate laid to stop 1:30 in padding for WPT over roof slab,filling of pressed steel door frame complete all as specified and directed
M&L for providing cement concrete type B 0, 1:2:4 using 12.5mm graded aggregate in cover fillet of 75 mm radius at junction of roof slab and parapet wall etc complete all as specified and directed
Removing of existing unserviceable water proofing treatment taking down cement plaster etc, of any description and cleaning of top surface of cement concrete flushing out junction of parapet walls & washing down with water to remove all dirt etc including preparation of surfaces to receive new treatment and removing the rubbish off premises complete all as specified and directed
M&L for applying cold bituminous primer @ 0.30 Ltr / Sqm conforming to IS 3384 laying APP polymer modified membrane 3mm thick 3 Kg/Sqm in weight with non-woven polyster reinforcement with plain finish and sealing all overlaps of 75mm in length side and 75mm on width side of membrane by torching the same as per manufacturer instruction and all as per specified particular specification including application of solar reflective aluminum paint @ 100gm / sqm complete all as specified and directed
Note:-(a) Rate quoted deemed to be inclusive of cleaning of surface to be treated properly to receve the primer all as directed by the Engr-in-Charge. (b) Necessary guirantee certificate shall be given by the manufacturer for enfficacy for the material for 10 years from the date of completion of work. (c) APP membrane treatment shall be done firstly at corners and junction of parapet wall 30cm on verticle position and 30cm on horizontal position shall be done with proper attention and work carried out by authorised applicator only. Main portion of roof treatment shall be commenced only on completion of corners/edges/junctions. (d) APP membrane shall be taken upto outside of the parapet wall to an extent of 150mm minimum. (e) Ensure while laying the treatment no bulging on surface/voids shall be found and proper care/attention be given for the treatment. (f) If any work executed at site without any authorised applicator, the same shall be rejected and no payment shall be considered (g) Contractor shall produce the certificate from the manufacturer for the authorised applicator before commencement of work.
M&L10mm thick screed bed in CM 1:4 mixed with WPT 3% by weight of cement complete all as specified and directed Note: WPC shall be measured and paid seperately.
Supply only intergral water proofing compound.
Demolition of wall of brick and stone wall built in cement mortor incl all quoins, archs, pillars,etc complete all as specified and directed
M&L Brick work with sub class B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
M&L for spl treatment to sunken portion (inc necessary dismantling of tiles and PCC along with req PCC at site of mix 1:2:4 of req thickness) with 10mm thck plaster in CM 1:4 with WPC Liq complast 421 and applying one coat each of Nitroproof 100 and Nitroproof 120 on plastered surface. Rendering again 10mm thick plaster in CM 1:4 mixed with complast 421 in sunken portion of WC and CI pipe joint shall be filled inc filling of lean conc 1:5:10 complete all as specified and directed
Dismantling of CI drain pipes 75/100mm internal dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F CI soil waste vent and rain water pipe 75 mm bore (ISI Marked) in any length with or without ears with cement joint laid in floor/fixed to wall complete all as specified and directed.
S&F CI soil waste vent and rain water pipe 100 mm bore (ISI Marked) in any length with or without ears with cement joint laid in floor/fixed to wall complete all as specified and directed.
S&F in repair cast iron floor trap 75 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1, (1:2:4) complete all as specified and directed.
S&F 100mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed
S&F 75mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed
S&F 100mm bore bend (any radius) with duck foot or heel rest complete all as specified and directed
S&F 75mm bore bend (any radius) with duck foot or heel rest complete all as specified and directed
Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed
M&L Preparation and Painting new Steel Surfaces with 2 coat Synthetic Enamel Paint of any description, over 10cm in width or girth,not otherwise described over Red Oxide Primer complete all as specified and directed
S&F in repair Chromium plated shower roses of 125mm size with or without swivel joints, anysize, including fixing to steel pipe or union complete all as specified and directed
Providing and injecting chemical emulsion along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed
Treating at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed
Treatment of soil under existing floors using emulsion @ one litre per hole,300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M & L Cement concrete 75mm thick as in plinth protection type C- 2, 1:3:6 (40mm graded aggregate) finished surface without using extra cement complete all as specified and directed
M&L Framed work ( Fe 290 gde E 165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed
S&F SS plate rack 1mm thick of Size 750mm x 900mm x 250mm Code No 1049 complete all as specified and directed
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes;including bedding in cementmortar on to dwarf wall or including fixing cantilever bracketsand connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out complete all as specified and directed
M&L Cement concrete in surface channels and drains type D2- 1:4:8 using 40mm graded agg complete all as specified and directed
M&L Cement concrete in foundations, filling, mass concrete, sub base for Interlocking etc. D2- 1:4:8 using 40mm graded agg complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removal of excavated soil to a distance n exc 50m depositing where distance at a level n.exc 1.5m heights from starting point complete all as specified and directed
M&L Pre-cast cement concrete block masonry with solid blocks 1:3:6 , exc. 10 cm in width and setting in mortar CM 1:6, complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 on brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for broken stone hardcore of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping of drain and the like including necessary form work weathering rounded or chamfered angles, throating including finishing the surface even and smooth without using extra cement complete all as specified and directed
Cement concrete in foundations filling and mass concrete type B2, 1:2:4 using 40mm graded aggregate complete all as specified and directed
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in sub base complete all as specified and directed.
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey cement and no pigment complete all as specified and directed
Description all as per Item No 107.00 Above exept Tiles.
Filleting in any position and to any shape in cement lime mortar 1:1:6 including all mitres, stops, etc complete all as specified and directed
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
M&L 75 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in sub base complete all as specified and directed
Providing precast cement concrete type B1 1:2:4 (20mm Agg) in Cement Mortar 1:4 as in window or door cills, lintels, bressumers, steps, quoin blocks complete all as specified and directed
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed
M&L for RCC M25, in foundations, including, rafts, footing, foundations beams; plinth beams,bases for columns,etc. basement slabs,under-reamed piles and mass concrete. (using 20mm graded aggregate) (Up to Ground Level) complete all as specified and directed
M&L for RCC M-25 (using 20mm aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed
M & L for RCC M-25 (using 20mm aggregate) to roof beam Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc complete all as specified and directed
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
M&L for RCC M-25 (using 20mm stone aggregate) as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M & L for TMT Bar Fe-500 (10mm dia and above) reinforcement for RCC work including bending binding and placing in postion with anneald wires etc . complete all as specified and directed
M & L for TMT Bar Fe-500 reinforcement for RCC (6-8mm as in stirrups) work including bending binding and placing in postion with anneald wires ertc . complete all as specified and directed
M&L for preparation of new surfaces of wall and applying three coats of white wash complete all as specified and directed
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed
S & F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed
S&F Grating square 150 mm size of PTMT (Minimum weight 100gms) complete all as specified and directed
M&L for bedding to drain pipes including packing under, and hawnching in PCC 1:3:6 type C2 using 40 mm graded aggregate against the side of 150mm SWG/NP2 pipes after they are laid and tested complete all as specified and directed
M&L for 150 mm bore Reinforced concrete pipe class NP2, laid and jointed complete with collars complete all as specified and directed
Taking down carefully point wiring including (light, fan, socket or power complete with fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed
M/L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed (FR) multistranded copper conductor cable 1100 volt grade enclosed in and including PVC conduit concealed wiring with accessories by means of PVC sleeves Dash fastners and cadmium plated screws all as per ISI including sunk type boxes for mounting fitting like switches, socketes fan regulators with 3 mm thick phenolic Laminated sheet top covers concealed in walls etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly complete all as specified and directed for the following:-
One light point controlled by one one/way switch.
One Fan/Ex fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with other switch.
One bell point controlled by one one/way switch.
Description all as per item No.130.00 above but wiring with 2.5 sqmm FR multistranded copper conductor unsheathed and 2.5 sqmm FR copper conductor unsheathed cable as earth continuity conductor for one 5 pin 15 Amps power socket outlet point on independent board complete all as specified and directed
M&L for sub main wiring using two run single core 6 Sqmm fire retardent PVC insulated and unsheathed cable with copper conductor 1100 vots grade, ISI mrked complete with PVC conduit accessories like bends tees etc and PVC insulatd copper cable 4 Sqmm FR for earth wire and connecting to earth dolly complete all as specified and directed
M&L for sub main wiring using two run single core 4 Sqmm fire retardent PVC insulated and unsheathed cable with copper conductor 1100 vots grade, ISI mrked complete with PVC conduit accessories like bends tees etc and PVC insulatd copper cable 4 Sqmm FR for earth wire and connecting to earth dolly complete all as specified and directed
S&F switch piano flush type single pole one way 5 Amp 240 Volts. complete all as specified and directed
S/F socket out let 2 in 1, 3 pin, 5 Amps flush type 240 Volt. complete all as specified and directed
S/F switch socket combination 3 pin 5 and 15 Amp 2 in one flush type universal complete all as specified and directed
S/F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. complete all as specified and directed
S&F Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V. complete all as specified and directed
S/F in DB's Sheet metal enclosure for SPN DB 12 way type 240 volts and 200 Amp ratings bus bar complete allas specified and directed. complete all as specified and directed
S&F MCB in the DBs given below complete all as specified and directed
MCB SP up to 32 Amp, 240 volts
MCB SPN upto 63 Amp, 240 volts
MCB 4 pole 100 Amp, 415 volts
Supply and fix exhaust fan,heavy duty steel body AC single Phase. 230V 1400 rpm of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. Make: Turboforce SKU.FHEHDSPDB120 of Havells or equivalent Usha / Bajaj/Orient. Note:- Making hole with hume pipe for fixing of exhaust fan deemed included in rate quoted and no extra payment should be made.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM, with service value 6.00 BEE. Five star,rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Supply and fix electronic meters tamper proof LCD display with polycarbonate cover 230 V, 10- 60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
Supply & fix 20 Amp Industrial metal clad plug in socket and plug top with 20 amp SP MCB complete all as specified and directed
Supply and fixing LED BULB 9 WATT Complete all as specified and directed
Supply and fixing LED light fitting 1x 20W, 220V, AC decorative aluminium body box type with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing LED inverter Tubelight fitting ENERGY Efficient 22 Watt with opal diffuser,IP 20 inbuilt battery back up aluminium body bright light with 25000 burning hours complete all as specified and directed
Supply and fixing LED Inverter Tubelight fitting ENERGY Efficient 10 Watt 2000 lumen bright light with 25000 burning hours complete all as specified and directed
Supply and fixing wall mounted light fitting including retrofit LED lamp upto 14 watt B22 champagne gold finish fixture with plastic body, Opal white PC diffuser for glare free light complete all as specified and directed. Make: CAT Part No LAFOECEITZI0014 of Havells or equivalent in Hallonix, Phillips, C&S, Orient, Syska
Supply and fixing in replacement LED inverter security light luminaire 30 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and directed
Supply and fix in replacment bracket for security light made up of 25 mm dia, 1.6 mtr long GI pipe, light grade, bend to required shape fixed to wall with 2 clamps made of 20x3mm mild steel flat minimum 15 cm long, 4 nos 8 mm dia bolts with nut complete all as specified and directed
Earthing complete as per electrical plate NO.3 of MES SSR Part I with galvanised steel plate earth electrode 600 mm x 600mm x 6 mm burried directly in ground in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and incl galvanised iron or steel earth lead wire 4 mm dia by mneans of bolts, nuts, check nuts and washers of galvanised iron or steel, earthing wire protected by galvanised iron or steel pipe 15 mm dia light grade and connected to main switch board or main control board watering pipe shall be 20 mm dia GI medium grade incl excavation and earth work in any type of soil, PCC pit, CI Frame, RCC covers complete all as specified and directed
S/F in DB's Sheet metal enclosure for SPN DB 4 way type 240 volts and 200 Amp ratings bus bar complete all as specified and directed.
S/F Exhaust fan 300 mm sweep single phase 230 volts ISI marked. complete all as specified and directed Note: all necessary arrangement such as wodden frame/cut in existing window frame/or making hole/ making good the disturbed surfacesor wall included in item rates.
Supply and fixing LED Tubelight fitting ENERGY Efficient 20 Watt 2000 lumen bright light with 25000 burning hours complete all as specified and directed
Supply and fixing LED street light fittings ENERGY Efficient 30 Watt bright light with 25000 burning hours complete all as specified and directed
Sand cushioning to underground cables with dry river sand complete all as specified in clause 19.75 of SSR Part-1 complete all as specified and directed Note:- Punned thickness shall be measured for payment.
Supply and fix burnt clay brick of size 230mm x 115mm x 75 mm complete all as specified and directed
S & F low density polyethylene pipes of pressure rating 6 kgf/square cm, 50 mm bore with all fittings, fixing on wall /laid in trenches for cable protection complete all as specified and directed
Supply and laying & testing 10 sqmm 2 core XLPE cable PVC insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable , (heavy duty), 1100 volts grade with stranded aluminium conductor complete all as specified and directed
M&L for cutting into existing steel tubing of dia 40/50 mm for laying/fixing of new connection of any size complete all as specified and directed
M&L for screwing existing steel tubing of dia 40/50 mm for laying/fixing of new connection of any size complete all as specified and directed
S & F 20 mm bore gun metel gate/globe valve with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed . Note rate of union/socket included in item rate.
M&L for concealed Point wiring complete as specified with 1100 volt grade 1.5sq.mm. (nominal area) FRLSH single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including rigid non-metallic PVC concealed conduit of minimum 20mm dia with all fittings, concealed in wall/roof /floor including with sunk type boxes suitable for decorative modular cover plates (inner and outer) for housing modular pattern switches/ sockets/ and flush mounting in the wall duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified and directed for :- Note:- Sunk type modular boxes and cover plates shall be measured and paid seperately.
One light point controlled by one one/way switch.
One Fan/Ex fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with other switch.
One bell point controlled by one one/way switch.
Description all as per item No.165.00 above but wiring with 2.5 sqmm FRLSH multistranded copper conductor unsheathed and cable 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 5 pin 15 Amps power socket outlet point on independent board complete all as specified and directed
M&L for sub main wiring using two run single core 10 Sqmm fire retardent PVC insulated and unsheathed cable with copper conductor 1100 vots grade, ISI mrked complete with PVC conduit accessories like bends tees etc and PVC insulatd copper cable 10 Sqmm for earth wire and connecting to earth dolly complete all as specified and directed
S & F Modular switch 1 way 6A, 1 module complete all as specified and directed
S & F Modular switch 1 way 16A, 1 module complete all as specified and directed
S & F Modular Bell push 6A, 1 module complete all as specified and directed
S & F modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed
S & F modular Socket, 6A / 16A - 2/3 pin combined 2 module complete all as specified and directed
Supply and fixing white cover plate with frame, 1 module with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixing white cover plate with frame, 2 module with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixing white cover plate with frame, 3module with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixing white cover plate with frame, 4 module with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixing white cover plate with frame, 8 module with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixing metal flush box 1/2 module with Brass screw and washers for mounting the fixtures including taking out the old box and making good didturbed surface after fixing the board complete all as specified and directed
Supply and fixing metal flush box 3 module with Brass screw and washers for mounting the fixtures including taking out the old box and making good didturbed surface after fixing the board complete all as specified and directed
Supply and fixing metal flush box 4 module with Brass screw and washers for mounting the fixtures including taking out the old box and making good didturbed surface after fixing the board complete all as specified and directed
Supply and fixing metal flush box 6/8 module with Brass screw and washers for mounting the fixtures including taking out the old box and making good didturbed surface after fixing the board complete all as specified and directed
Supply and fixing TV jack complete mounted on board complete all as specified and directed
Supply ad fixing PVC pipe of size minimum 20mm complete for laying submain / TV dish cable complete all as specified and directed
Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1 :3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting exceeding 20cm girth complete all as specified and directed
Supply and fixing LED Tubelight fitting ENERGY Efficient 10 watt 2000 lumen bright light with 25000 burning hours complete all as specified and directed
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, including connection Stainless steel conection pipe etc. and making surface good complete all as specified and directed. Note All necessary arrangemnt for fixing of geyser such as drilling/ancor hold fastener included in item rates.
Supply and fix Wall mounted fans, complete with three blade, accessories 230V, 450mm sweep, 5 Star rated with Squirrel cage induction motor complete all as specified and directed .
M/S HARI CONSTRUCTION
SHREE KHODIYAR TRADERS
City Light
shree nathji trading corporation
OM SREE MAHADEV TRADERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .