| 1 | L1₹9.5 LAccepted-AOC AMLA TOLA DISTT KATIHAR BIHAR 854105 | KATIHAR | BIHAR | 854105 | ₹9.5 L Quoted ₹9.6 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹9.7 L+₹9,385 (0.98%)Rejected-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | ₹9.7 L+₹9,385 (0.98%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹9.8 L+₹14,361.50 (1.49%)Rejected-Finance | ₹9.8 L+₹14,361.50 (1.49%) | L3 | Rejected-Finance Higher bid value |
Tender Value
₹8.9 L
EMD Value
₹17,800
Closing Date
3 Jun 2020, 6:00 pmClosed
AGE (I) (AF) PURNEA
AGE (I) (AF) PURNEA,CHUNAPUR,PURNEA
REPAIR/REPLACEMENT OF LED STREET LIGHTS,PANELS AND ITS CONNECTED ITEMS AND ALLIED WORKS AT MOUZA DALAN AT ARMY STATION KATIHAR UNDER AGE (I) (AF) PURNEA
2020_MES_343056_1
C/8834/E8
Open Tender
Civil Works
Item Rate
210 days
AGE (I) (AF) PURNEA
AS PER NIT
7 documents required · 7 mandatory
₹500
AGE I AF PURNEA
₹17,800
Yes
11 Jun 2020
6 May 2020
8 Jun 2020
6 May 2020
3 Jun 2020
21 May 2020
Amount
Taking down care fully U/S street light fitting HPSV /HPMV/ CFL fitting from pole/ Bldg for repair / replecement of fitting after disconnecting of electrical connection all as specified & directed at site by the Engr- in- Charge.
S&F LED street light luminare 72 watt , with Penut lens powder coated pressure die cast aluminium with heat resistant toughned glass with lens and potel driver,seprate surge protection ,necessary wiring complete all as specified by Engr- in -Charge. (Make : Philips Cat Part No-BRP410 LED CW 072 MR FG S1 PSU GR
S&F LED Flood light of 150 watt Powder Coated , necessary wiring arrangment complete all as specified and directed by Engineer-in-charge.Make-Havells,Cat No-LHEPCUU7PATE150
M&L for G.I (medium grade, ISI ) pipe 32 mm dia, 1.5 Mtr long light grade, bend to shape for street light fittings bracket, with 2x pairs of MS clamps of suitable length of size 40 mm x 5 mm of MS flat iron with nuts, bolts & washer including applying two coats Synthetic enamel aluminium paint over a coat of red-oxide taking out old one.
S & F in replacement weather proof junction box made of thermoplastic polycarbonate with gasket comply with -IP 66,dust and jet water proof of size 155x210x92 mm suitable size for cable size upto 10 to 16 sqmm alongwith cable inlet with for terminal controled with MCB 6 Amp "C" curve omplete with necessary items including a pairs of MS flat iron Clamp of size 40mmx5mm with 10mm nuts, bolts of suitable length with washer, including 2 coats of synthetic enamel aluminium paint(first grade) over a coat or red oxide primer suitable to fix in Steel tubular pole/PCC pole after taking down old one all as specifid and directed. Make : Hensel Cat Part No-DK 1616G
M&L for 15mm dia steel tubes (light grade) galvanised with fittings, for wire connection to street light on pole complete all as specified and directed. (MAKE: JINDAL/PRAKASH/SURYA)
Taking out old unserviceable LT cables of any sizes & type from the trenches or pipe etc including taking out brick cable protection if required (Excavation on if any mesured & paid separately )
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core including cable glands and necessary lugs and both the ends
S&F cable PVC insulated type 2.5 sqmm 3 core copper conductor cable including taking out old and unserviceable cable from juction box to street light fiting. Make- Havell's/ finolex.
M & L Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth in foundation of pole/ laying of under ground cable and getting out in soft/loose soil complete all as specified and as directed.
M & L Returning filling incl spreading leveling watering and well ramming in layers n.esc 25 cm thick soft/loose soil complete all as specified and as directed.
M & L Removing surplus excavated soils n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M & L for Sand covering /cushioning for under ground cable protection complete all as specified and as directed
M&L for burnt bricks sub class 'B' laid perpendicular over & cushioning for cable protectioncomplete all as specified & directed at site by the Engr- in Charge.
Reuse of old bricks obtained from relevent Item Ser No laid in trenches above sand cushioning for cable protection complete all as specified and as directed. Note:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
M/S. R.K. ENTERPRISES
M/S. MAJUMDER CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .