Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
30 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
(PH-31)
ADEN LINE
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less: where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfillment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a work contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
Defination of Similar Work :- Any civil engineering works.
20 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
General Conditions of the Contract (GCC), 2022 is applicable to this contract.
Non-compliance with any of the conditions set forth therein above is liable to result in the tender being rejected.
It shall not be obligatory on the said authority to accept the lowest tender and no tenderer/tenderers shall demand any explanation for the cause of rejection of his/their tender.
If the tenderers deliberately gives/give wrong information in his/their tender or creates/create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage.
If the tenderer/s expires after the submission of his/their tender or after the acceptance of his tender, the Rly. shall deem such tender as cancelled. If a partner of a firm expires after the submission of their tender or after the acceptance of their tender, the Railway shall deem such tender as cancelled unless the firm retains its character.
Ancillary work of level crossing in connection with TTR work & Provision of toilets and water facilities at various manned level crossings in Merta Road- Jodhpur section under ADEN/Line-I Jurisdiction.
185OF2026-27~NWR
185OF2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹5.2 L
6 Nov 2026
6 Nov 2026
16 Nov 2026
86 items across 2 schedules · ₹7,33,301 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | All kinds of soil | Sqm | 50 | 129.85 | 6,492.5 |
| 2 | All kinds of soil. | cum | 1070 | 260.3 | 2,78,521 |
| 3 | Ordinary rock | cum | 60 | 632.95 | 37,977 |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. | cum | 140 | 196 | 27,440 |
| 5 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | cum | 1040 | 700.5 | 7,28,520 |
| 6 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) | cum | 130 | 7,178.75 | 9,33,237.5 |
| 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | cum | 160 | 6,812 | 10,89,920 |
| 8 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | cum | 1.6 | 9,895.2 | 15,832.32 |
| 9 | cum | 40 | 11,505.5 | 4,60,220 | |
| 10 | Suspended floors, roofs, landings, balconies and access platform | Sqm | 220 | 927.25 | 2,03,995 |
| 11 | Lintels, beams, plinth beams, girders, bressummers and cantilevers | Sqm | 320 | 736.4 | 2,35,648 |
| 12 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | cum | 16 | 10,585.9 | 1,69,374.4 |
| 13 | Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | cum | 6 | 14,325.95 | 85,955.7 |
| 14 | Thermo-Mechanically Treated bars of grade Fe- 500D or more. | Kg | 7500 | 107.85 | 8,08,875 |
| 15 | Cement mortar 1:6 (1 cement : 6 coarse sand) | cum | 490 | 7,311.25 | 35,82,512.5 |
| 16 | Cement mortar 1:6 (1 cement : 6 coarse sand) | cum | 80 | 9,275.45 | 7,42,036 |
| 17 | Masonry work (second sort), in cement mortar 1:6 (1 cement: 6 coarse sand) | cum | 440 | 10,128.1 | 44,56,364 |
| 18 | 100x58x1.90 mm | Each | 60 | 48.2 | 2,892 |
| 19 | 250x16 mm | Each | 20 | 193.7 | 3,874 |
| 20 | 150x10 mm | Each | 20 | 59.45 | 1,189 |
| 21 | 100 mm | Each | 40 | 32.55 | 1,302 |
| 22 | Extruded section profile size 48x40 mm | Metre | 120 | 270.2 | 32,424 |
| 23 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm ( +/- 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm ( +/- 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm ( +/- 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm ( +/- 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in- charge. (For W.C. and bathroom door shutter). | Sqm | 39 | 2,969.25 | 1,15,800.75 |
| 24 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | Kg | 35800 | 133.7 | 47,86,460 |
| 25 | Electric resistance or induction butt welded tubes | Kg | 100 | 194.4 | 19,440 |
| 26 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | Kg | 200 | 172.6 | 34,520 |
| 27 | 25 mm thick | Sqm | 150 | 1,948.25 | 2,92,237.5 |
| 28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 90 | 1,096.55 | 98,689.5 |
| 29 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 290 | 1,112.7 | 3,22,683 |
| 30 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 150 | 738.65 | 1,10,797.5 |
| 31 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). | Sqm | 600 | 518.55 | 3,11,130 |
| 32 | Flush/ Ruled pointing | Sqm | 1200 | 385.4 | 4,62,480 |
| 33 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre | Sqm | 160 | 185.65 | 29,704 |
| 34 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture | Sqm | 200 | 226.25 | 45,250 |
| 35 | Lettering with black Japan paint of approved brand and manufacture | per letter per cm height | 50000 | 6.15 | 3,07,500 |
| 36 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | Sqm | 200 | 156.05 | 31,210 |
| 37 | Old work (one or more coats) | Sqm | 300 | 62.7 | 18,810 |
| 38 | One or more coats on old work | Sqm | 200 | 102.8 | 20,560 |
| 39 | Water bound macadam road | Sqm | 200 | 217.45 | 43,490 |
| 40 | bituminous road | Sqm | 200 | 428.5 | 85,700 |
| 41 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in- charge, beyond 50 m initial lead, for all leads including all lifts involved. | cum | 50 | 263.95 | 13,197.5 |
| 42 | 63 mm to 45 mm size stone aggregate | cum | 220 | 1,636.05 | 3,59,931 |
| 43 | 53 mm to 22.4 mm size stone aggregate | cum | 180 | 1,842.3 | 3,31,614 |
| 44 | Stone screening 11.2 mm nominal size (Type B) | cum | 50 | 2,247.75 | 1,12,387.5 |
| 45 | Moorum | cum | 20 | 768.25 | 15,365 |
| 46 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . | cum | 400 | 1,046.95 | 4,18,780 |
| 47 | On W.B.M / W.M.M. @ 0.4kg/sqm | Sqm | 1000 | 13.45 | 13,450 |
| 48 | On bituminous surface @ 0.25kg/sqm | Sqm | 5500 | 14.05 | 77,275 |
| 49 | With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt | Sqm | 6500 | 531.6 | 34,55,400 |
| 50 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. | cum | 300 | 7,993.8 | 23,98,140 |
| 51 | Cement concrete prepared with batch mixing machine | cum | 350 | 10,529.35 | 36,85,272.5 |
| 52 | Old work (One or more coats) | Sqm | 40 | 189.85 | 7,594 |
| 53 | Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acrylonitrile ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. | Each | 150 | 206.3 | 30,945 |
| 54 | Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in- charge and accordance with applicable specifications. | Sqm | 100 | 747.8 | 74,780 |
| 55 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. | Sqm | 900 | 131.75 | 1,18,575 |
| 56 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. | Sqm | 700 | 1,091.5 | 7,64,050 |
| 57 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 30 | 6,767.4 | 2,03,022 |
| 58 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 20 | 2,648.85 | 52,977 |
| 59 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap | Each | 10 | 1,879.2 | 18,792 |
| 60 | Sand cast iron S&S pipe as per IS: 1729 | Metre | 60 | 1,151.9 | 69,114 |
| 61 | Sand cast iron S&S as per IS - 1729 | Each | 20 | 598.5 | 11,970 |
| 62 | Sand cast iron S&S as per iron 1729 | Each | 20 | 698.05 | 13,961 |
| 63 | Sand cast iron S&S as per IS - 1729 | Each | 20 | 442 | 8,840 |
| 64 | 20 mm nominal dia Pipes | Metre | 100 | 335 | 33,500 |
| 65 | 20 mm nominal dia Pipes | Metre | 2100 | 537.6 | 11,28,960 |
| 66 | 25 mm nominal dia Pipes | Metre | 200 | 355.4 | 71,080 |
| 67 | 25 mm dia nominal bore | Metre | 100 | 551.7 | 55,170 |
| 68 | 15 mm dia nominal bore | Metre | 300 | 580.45 | 1,74,135 |
| 69 | 15 mm dia nominal bore | Metre | 400 | 322.15 | 1,28,860 |
| 70 | 25 to 40 mm nominal bore | Each | 20 | 911.9 | 18,238 |
| 71 | 15 mm nominal bore | Each | 20 | 353.25 | 7,065 |
| 72 | 25 mm nominal bore | Each | 20 | 622.4 | 12,448 |
| 73 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Per Litre | 20000 | 11 | 2,20,000 |
| 74 | 15 mm nominal bore, 122 mm long, weighing not less than 99 gms | Each | 20 | 161.2 | 3,224 |
| 75 | 20 mm nominal bore, 89 mm long, weighing not less than 88 gms | Each | 20 | 129.9 | 2,598 |
| 76 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms | Each | 20 | 156.9 | 3,138 |
| 77 | 100 mm diameter | Metre | 200 | 443.6 | 88,720 |
| 78 | 100 mm diameter S.W. pipe | Metre | 200 | 964.75 | 1,92,950 |
| 79 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | cum | 5 | 8,042.3 | 40,211.5 |
| 80 | P r o v i d i n g and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric water proofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric water proofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. | Sqm | 200 | 563.1 | 1,12,620 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
FinalSTDWorks12.2.20191.pdf
ATTACHMENT
CorrigendumintenderdocumentJU01052023.pdf
ATTACHMENT
AdvanceCorrectionSlipNo01to12.pdf
ATTACHMENT
AnnexureVofGCC.pdf
ATTACHMENT
SeekingclarificationonapplicabilityofGCCCorrectionSlipNo1024-06-2025.pdf
ATTACHMENT
GCC2022ACS102repaired2025compressed1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .