| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹14.8 L+₹93,001 (6.70%)Rejected-Finance H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.7 L+₹1.8 L (13.0%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹15.7 L
EMD Value
₹31,100
Closing Date
25 Mar 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Electrical Division HPPWD Palampur
C/O Circuit house at Palampur in Tehsil Palampur Distt. Kangra (HP) (SH- Providing, Installation, testing and commissioning of 125 kVA Silent DG set)
2022_PWD_58241_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
30 days
Palampur in Distt. Kangra
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
₹31,100
20 Nov 2025
19 Mar 2022
25 Mar 2022
19 Mar 2022
25 Mar 2022
19 Mar 2022
120 days
Amount
Providing, installation, testing and commissioning of 'Silent' type Diesel Generating Set as per CPCB-II norms alongwith having Prime Power Rating of 125 kVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 Volt suitable for 50Hz, 3 Phase System and consisting of the following and as per specifications and conditions:
Diesel Engine:
Diesel Engine 4 Stroke cycle, Water Cooled , turbocharged charge air-cooled developing 159 BHP at 1500 RPM under NTP conditions of BS:5514. 30.35 litre/hour fuel consumption @100% load with radiator and fan, 12V DC Electrical starting system, 21.4 litre total lubrication system capacity, 26 litre total coolant capacity, exhaust pipe 4" and exhaust temperature 553°C . The engine will be fitted completed with all the required accessories.
(Makes:- Sudhir/Kirloskar/Ashok layland
Specifications:
Cummins B5.9 series, 6 cylinder, in-line 4 stroke, radiator cooled engine.
Well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator, Air to air aftercooling, optimised turbocharger for increased altitude capabilities.
Optimised fuel consumption with inline fuel pump with mechanical governing, spin on dual fuel filter with water separator.
Standard integral set-mounted radiator system, desingned and tested for 50oC ambient temperatures.
Full flow spin on lube oil filter
First fill of lube oil and coolant
Electric starter motor with soft start engagement feature
Battery charging alternator
1x12 V DC battery
Alternator:
Sychronous alternator rated at 125 kVA, 415 volts at 1500 RPM, 3 Phase 50 Hz, AC supply with 0.8 lagging power factor at 40oC, 50% RH at 1000 Meters MSL. The alternator shall be having IP23 enclosure, brushless type, continuos duty, self excited conforming to IS/IEC 60034-1, 3 phase reconnectable winding with 12 terminals brought out for connection, better motor starting capability, dynamically balanced rotor, compact design with sealed bearings for longer life and lesser maintenance and impregnation on all wound components for better mechanical strength.
(Makes:- Sudhir/Kirloskar/Ashok layland
Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangemnt as per recommendations of the manufacturer. The foundation shall be 400mm below the ground level and 150mm above the ground level.
Fuel Tank:
Daily service fuel tank of standard 290 litres capacity fabricated out of MS sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. complete with valves, level indications and accessories as required as per specifications.
Exhaust System:
Dry exhaust mainfold with Residential Silencer as per manufacturer specification.
Starting System:
12 volt DC starting system compring of starter motors: voltage regulator and arrangement for initial excitation complete with 1 No. 12 volts battery of 90 Amp. hours capacity lead acid type sealed maintenance free as required as per specifcations.
(Makes:- Sudhir/Kirloskar/Ashok layland
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air into the atmosphere as per specifications and CPCB-II norms.
Supplying, installation, testing and commissioning of automatic mains failure panel, fabricated with 2mm thick CRCA sheet duly supported with MS channels suitable for 125 KVA DG Set complete with relays, timers, set of CTs for metering and protection to indicate line currents, phase and line voltages, frequency, power factor, KWH to provide overload, short circuit, restricted earth fault, under frequency, over frequency protection, contactors and other instruments including KWH meter. power factor meter, frequency meter , control cabling from AMF Panel to diesel engine and also to MCCB on LT distribution panel and inter locking as required including following:
Current transformer 15 VA Class-I accuracy.
Frequency meter
Digital type power factor meter.
Indicating lamps for load on mains and load on set.
Fuses for instruments.
Control unit with three impulse automatic engine start/stop and failure to start lockout.
On/Off Control Circuit Switch.
Audio/Video annunciation for
i) High water temprature.
ii) Low Lubricating oil pressure.
iii) Engine over speed.
iv) Over current and earth fault.
v) Engine fails and start.
Aluminium bus bars with suitable capacity with in/outgoing terminals.
MCCB of suitable rating with overload and short circuit protections.
Providing/filling Diesel in the existing Diesel Set of Generator as required complete in all respect.
Excavation in foundation, trenches etc. in earth work, lift upto 1.50 meters stacking the excavated soil not more than 3 meters clear from the edge of excavation and then returning the stacked soil in 15 cm layers, when required into plinths sides of foundations etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 meters complete in pick and jumper work.
Providing and laying cement concrete 1:4:8 (1 Cement: 4 Sand: 8 graded crushed stone aggregate 40mm nominal size) and cutting complete excluding cost of form work in foundation and plinth.
Providing form work with steel plates 3.15mm (Three decimal one five millimeters) thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centering, shuttering, structting and propping etc. with wodden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for institu-reinforced concrete & plain contcrete work in. foundation, footings basis of columns etc. and mass concrete.
Providing and laying plain cement concrete 1:2:4 (1 Cement : 2 Sand : 4 graded stone aggregate 20mm nominal size) mechanically mixed and vibrated and curing complete excluding cost of form work in foundation and plinth etc.
Filling in plinth with sand under floors including watering ramming consolidating and dressing complete.
SUB-HEAD-II :- EARTHING & LOOP EARTHING
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip in 40 mm dia. G.I. pipe from earth electrode etc. as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
SUB-HEAD-III :- WIRING & CABLE LAYING
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-
300 mm deep (nominal)
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required. Make:- L&T, Legrand, Schneider
200 Amp. -25 KA
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required. Make:- L&T, Legrand, Schneider
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- Make:- KEI/SCI/Havells/Plaza
Armoured cable 150 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Make:- KEI/SCI/Havells/Plaza
Armoured cable 150 sq. mm (3.5 core)
Providing & laying of One No. copper conductor, PVC insulated and PVC sheathed armoured/XLPE power cable, working voltage 1100 volts grade direct in groungd to be laid 1 Meter below the ground level i/c excavation amd refilling the trench etc. as required, but excluding sand cushioning and protective covering. Make:- KEI/SCI/Havells/Plaza
2.5 sqmm 6 core
Deepak Sood
Kalra Hardware and Electric Store
stage.html
html • 0.05 MB
technical_88007.pdf
techsummary_88007.pdf
finance_88007.pdf
BOQ Comparative Chart
xlsx
finsummary_88007.pdf
cancelled_1.pdf
pdf • 0.47 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
GCC5DGset125kvaCircuitHousePalampur.pdf
Tender Documents • 3.24 MB
BOQ_88007.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .