EXECUTIVE ENGINEER MECHANICAL DIVISION BARAMULLA
THE EXECUTIVE ENGINEER MECHANICAL DIVISION BARAMULLA
Construction of Snow Clearance Control Room / Accommodation of Supervisory Staff and other Infrastructure at Bandipora (Mangnipora Estate) by way of Electrification and Finishing works
2022_PWDJK_184532_1
MDB/TS/e-TENDER/2022-23/71
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
Baramulla
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
EXECUTIVE ENGINEER MECHANICAL DIVISION BARAMULLA
₹2,428
10 Nov 2022
18 Aug 2022
13 Oct 2022
18 Aug 2022
12 Sept 2022
18 Aug 2022
Amount
Providing, Installation and testing of Automatic Mainline Servo Voltage stabilizer (50v-280v) Single Phase Copper wound, conforming to relevant IS code and having following features. Phase=Single phase, Input voltage range=50-200 Volts, Output Voltage=220Volts, Capacity=5KVA, Frequency=50 Hz, Material=MS, Regulation =fully Automatic Over load protection =Via MCB (Stabilizer on/off mains) The job shall include providing and laying of cable in copper (multithread) with PVC insulation of 4mm cross section area of 20 meters long up to main switch board including thimbling and channel conduit where ever required.
Supply installation and testing of reputed make 1050 VA Pure Sine Wave Inverter, to be installed and tested at Snow clearance control room Bandipora. The job shall include providing and fitting of (two core) 1mm square copper wire (20 mtr) including 3 pin sockets (02No) ,SS combine (02No),3 pin top (02No).
Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc, including priming coat complete of Second Class Kail Wood at equal distances of 1.5 Ft. on each side. The job also includes providing and fixing of specified wood frame work for 3ftx 7 ft door consisting of battens 100x75 mm fixed with rawl plug and drilling necessary holes for rawl plug etc, including priming coat complete of Second Class Kail Wood.
Providing and fixing of 12 mm thick main plywood conforming to IS:710 over the wooden framed structure under the roof and closing the open side of the above stair area. The job includes painting of the whole structure after applying wood primer followed by two coats of white wood paint.
Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter of size 3ftx7 ft conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and paneling with panels of 12 mm thick plain grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848.
Providing and fitting of 3” dia GI pipe (A-Class) threaded on both ends as exhaust along with Chumni cap for Bukharis at Control room Bandipora up to 1mtr above the existing roof along with all fittings.
Providing and fitting of 50 watts wall mounted outdoor type flood lights at various spots ( identified by site engineer) inside the control room yard along with 2 core 1.5mm copper wire (25 Mtr each) through channel/ conduit along with16 amp MCBs as per the site Requirement. Wattage =50w Lumens output=5000 lumens 1p rating = Ip 66 water resistant Power Factor=0.9 Product Life=25000 Hrs or more Warranty= 2 years
Providing and fitting of 30 watts wall mounted outdoor type flood lights at various spots ( identified by site engineer) inside the control room yard along with 2 core 1.5mm copper wire (25 Mtr each) through channel/ conduit along with16 amp MCBs as per the site Requirement. Wattage =30wat Ip rating = Ip 65 Water resistant Product Life=25000 Hrs or more Warranty= 2 years
Providing and fitting of 63 Amp. automatic Changeover between direct line and DG set to output power supply as per the site requirement with following specifications: Capacity: 63 Amps Working range= 90 to 300 Volt Current Type = AC Single phase Operation Mode= automatic
M/s Sopore Engineering Works
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .