E.E.(E) BSNL ED Ahmedabad
BSNL ED TE Navarangpura Ahmedabad
AMC and attending faults on call base for TE / Sites at BSNL ATD Ahmedabad
2023_BSNL_179868_1
60/EEEA/BSNL2023-24
Open Tender
Electrical Works
Item Rate
365 days
AHMEDABAD
As per NIT
2 documents required · 2 mandatory
₹590
AO Cash BSNL Ahmedabd
₹46,914
Yes
20 Jan 2024
30 Dec 2023
19 Jan 2024
30 Dec 2023
18 Jan 2024
30 Dec 2023
30 Dec 2023 - 18 Jan 2024
Amount
SH-I (AMC)
Annual Comprehensive Maintenance of 1.5 / 2 TR Window / Split / HSAC units / Free Cooling Units installed at various GSM BTS Sites / exchanges under including attending fault on Comprehensive basis covering all items such as incomer MCB, Voltage stabilizer / controller / wiring / compressor / filter etc attached with existing AC / Free Cooling units of following size , incl. cleaning of Filter for FCU etc. as required for proper working of units , as required. (i) 1.5TR Window / Split AC Units ( Qty.373 Units Per Month i.e. 4476 Units for 12 Months )
(ii) 2TR Window / Split AC Units ( Qty.96 Units Per Month i.e. 1152 Units for 12 Month)
(iii) 2 x1.5 TR HSAC Units ( Qty. 4 Units Per Month Units for 12 Month)
(iv) 2 x2 TR HSAC Units ( Qty. 4 Units Per Month i.e. 108 Units for 12 Months )
SH II Call Base Repairing of AC Units (6.1.) Replacing of following faulty parts with brand new spares suitable for 1.5 / 2.0 TR WINDOW AC units i/c credit of non returning of faulty parts i/c testing, commissioning etc. as reqd.(i) Thermostate
(ii) Blower fan motor for WAC
(iii) Fan Motor capacitor 2.5/5 MFD
(iv) Condenser Fan Blade
(v) Blower Drum
Replacing of following faulty parts with brand new spares suitable for 1.5 / 2.0 TR SPLIT AC units i/c credit of non returning of faulty parts i/c testing, commissioning etc. as reqd (a)Blower Motor
(b)Blower Drum
( c ) Condenser Motor
(d) Condenser Fan Blade
(e) PCB Repair for Indoor Unit
(f) PCB Repair for Condenser Unit
(g)Rotory Compressor ( Test Certificate of manufactor will be required) (a) 1.5 TR
(h)Rotory Compressor ( Test Certificate of manufactor will be required) (b) 2.0 TR
(i)Capacitor 25-35/5 MFD
(j) 2 Ploe Contactor 25 Amp
(k)Terminal Box ( Connector ) 4/6 way
Water servicing of 1.5 / 2 TR Window AC / split AC unit / HPAC units with complete cleaning i/c cleaning condencer coil with suitable Chemical
Blower Servicing & Cleaning of 1.5 / 2 TR Split AC Units / 2 x 1.5 TR High Sensible AC Units of various BTS/TE Buildings at City area and Rural area including taking out Window AC out side ,blowring out all dust from the complete units and put in working condition etc. complete as required.
Carrying out leak testing of Window/ Split AC unit with nitrogen gas, brazing the leak points, flushing the system, vaccumizing, making the system leak proof, testing & commissioning by carging required quantity of R22 / R410 refrigerent gas etc. complete as reqd.
Replacement of 50 mm thick 600 mm x 600 mm microvee type washable synthetic filter inside the GI frame having efficiency above 90% down to the particals of 05 microns suitable for FCU installed in BTS shelter.
Supplying and fixing of Auto sequential programable mode Micro controller for two Nos. 1.5/2TR WAC/Split A C units with built in cylic timer ( 4Hrs) capable of operating on 230 Volt, 50Hz single phase A C supply having inbuilt features of temperature sensor with settable over temperature alarm and potential free contacts for extension of the alram High and low voltage cut off arrangement, over load tripping, housed in M S box of appropriate size fabricated out of 16 guage M. S. sheet powder coated having power relays for operation on 100% A C current with 20% over load including making intreconnectoions with 3 core PVC insulated PVC sheathed coper conductor wire of 2.5 sqmm cross section with following LED indications etc.complete as required. (BSNL approved make) ( Item shall be got approved from Engineer-in-charge before installation).
Replacement of faulty SPN MCB C series 25 Amps in existing DB as reqd
Site Visit for checking and attending the defects / faults with minor petty material (Costing below Rs 100/-) including attending minor complaints / faults at various BTS / Exchanges, damage of control wiring of Split AC / AC Pkg Units by the rat cutting etc. as below etc. complete as required (For payments for this item, faults must be attended) .
RESHA ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .