Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest quoted bidder. | |
| 2 | L2₹22.7 L+₹4.7 L (26.0%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹22.7 L+₹4.8 L (26.4%)Rejected-Finance SRIPUR BICHWA VILLAGE MAJRA FARM KHATIMA UDHAM SINGH NAGAR UTTARAKHAND 262308 | KHATIMA | UDHAM SINGH NAGAR | UTTARAKHAND | 262308 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹24.3 L+₹6.3 L (35.2%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹31.3 L
EMD Value
₹63,000
Closing Date
23 Jan 2023, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
SPL REP TO BLDG NO T-20 AND PROVN OF CAR PARKING SHEDS AT O MESS AND AT PT GROUND OF JAK AT MIL STN BANBASA UNDER GE PITHORAGARH
2022_MES_571381_1
8504/BAN/E8
Open Tender
Civil Works
Item Rate
180 days
GE Pithoragarh
Class D, Category a(i)
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹63,000
Yes
13 Feb 2023
26 Dec 2022
30 Jan 2023
26 Dec 2022
23 Jan 2023
9 Jan 2023
Amount
DESCRIPTION OF ITEMS
Dismantling of AC corrugated, semi-corrugated sheets in roof coverings & ridges.
S & F of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick trapezoidal pattern of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantling 40 sq cm and over in framed work in any position.
S & F of second class hard wood timber scantling clean sawn framed and fixed in any position and direction complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
S & F of suspended false ceiling system of grid/section size 600x600mm comprising of GI powder coated main 39x24x0.8mm thick (thickness comprising of GI/0.40+PPGS/0.3), cross TEE 29X24X0.8mm thick and wall angle 22.2x22.2x0.65mm thick duly suspend with 6 mm dia GI wire hangers fixed with steel dash fasteners or from purlin of the roof with clip including 4mm thick E- Board tiles for insulation and acoustic purpose of size 600x600mm to be placed in the grid system complete all as speceified and directed.
Demolition of brick work /stone work built in cement mortar all as specified and directed.
M & L for brick work built in CM 1:6 with sub class old size bricks straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M & L for vitrified tiles (light shade) 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, laid over and including 15mm thick screed bed in CM (1:6) as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for vitrified tiles (light shade) 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, laid over and including 10mm thick rendering in CM (1:4) as in skirting/dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for glazed ceramic coloured wall tiles 300x450mm as in vertical surface such as skirting/dado tiles including 10mm thick rendering in CM(1:4) as in back coat of tiles set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade complete all as specified and directed.
M & L for machine cut Kota stone slab flooring 20-25mm thick over and including 15 mm thick screed bed in CM (1:6) laid and bedded jointed in cement slurry mixed with pigment to match to shade of the slab incuding grinding, mirror polishing complete all as specified and directed.
M & L for 20mm thick granite work of any type and shade (table rubbed and polished) in floors, steps, jambs, pillars, window cills, cooking platforms and like in CM(1:4) incl pointing in white cement(1:2) using marble dust with admixture of pigment to match the shade of granite stone including providing edge moulding . including machine polishing to edge to give high gloss finish etc. complete over and incl 15mm thick screed bed in CM(1:4) complete all as specified and directed.
Demolition of cement concrete unreinforced in Ground floor & paving n.exc 15cm thickness and removal of debris from site all as specified and directed.
M & L for 75mm thick cement concrete type C1 (1:3:6) using 20mm graded aggregate as in path, plinth protection finished surface even and smooth with out using extra cement all as specified and directed.
Taking down cement plaster of any description in any position incl raking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.
Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in cement mortar; not previously plastered; and scrubbing down with water etc. to receive plaster and removal of debris from site all as specified and directed.
M & L for 15mm thick rendering in CM (1:4) on fair faces of brick work in walls and finishing the surfaces even and fair complete all as specified and directed.
M & L for 15mm thick rendering in CM (1:6) on other than fair faces of brick work in walls and finishing the surfaces even and fair complete all as specified and directed.
M & L for preparation of new wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L for preparation of new wall surfaces and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for complete removal of existing treatment on walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed.
M & L for preparation of new wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down chowkhats or frames with shutter(without taking off shutter from the frame) area not exc. 1.5 Sqm and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down chowkhats of any description without taking of shutter from the frame exceeding 1.5 Sqm but not exc. 4.0 Sqm each and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down shutters of any description area exceeding 1.0Sqm but not exc 2.0Sqm and removing from site all as specified and directed.
M & L IInd class hard wood plain solid straight chowkats and frame wrought, framed rebated on the solid put together with glue, pinned at joints and fixed in position complete all as specified and directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles conforming to Fe 410-O 0r Fe 310-O complete all as specified and directed.
M & L for Plain Cement Concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in bed blocks for hold fast, coping, benching and similar work etc complete all as specified and directed.
S & F of 30 mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F mild steel Butt hinges of medium weight and fixed 100mm all as specified and directed
S & F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S & F of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and overall length of cover plate 150mm, fixed in floor complete all as specified and directed.
S & F of aluminium (extruded section body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S & F of standard aluminum section powder coated as approved for door frames/window & ventilator frames/ shutters / sliding / fixed / gauged/ louvered and partion etc including, jointing cleat and rubber beading /lining, pivot, stay, locking arrangement, fittings and fixed in postion with stainless steel screws including the cost of EPDM rubber/neoprene gasket required and including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc complete all as specified and directed.
S & F of anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.
S & F of tinted sheet glass 5.0mm thick ordinary quality with oil putty or rubber and aluminium beading in squares exc.0.5 Sqm in each pane complete all as specified and directed
S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair 25mm stainless steel curtain rods with fixing brackets, stops, rollers, knobs etc complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete and removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE Banbasa complete all as specified and as directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for following :- (a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(e) One bell point controlled by one, bell switch 5 Amps
Description all as per item No 52 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
Description all as per item No 52 here in before but using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point)
S & F in repair Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F in repair switch bell push piano type 5 amp, 230 Volts Complete all as specified and directed at site.
S & F in repair socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F in repair Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F in repair stepped type electronic fan regulator flushType complete all as specified and directed at site.
S & F in repair lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
S & F in repair Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
M & L in repair Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 Sqmm cable,one run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F in repair Isolator tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F in repair MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F in repair MCB Single pole rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps complete all as specified and as directed complete all as specified and as directed
Fixing only the celing fan with copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal complete all as specified and as directed.
Supply and fixing in repair LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
M&L earthing in repair complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed.
Supply and Fixing in replacement LED bulb 12W,5 star rated voltage 220-240, 50 Hz, CDL 1200 lumen B22 base type for batten/angular lamp holder as directed.
Excavation in post holes in soft/loose soil (or similar holes) each not exc 0.5 Cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm all as specified and directed.
M & L for cement concrete type C-2 (1:3:6) using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W (Gde- E- 250) quality-A complete all as specified and as directed.
S & F of rolled mild steel works as in bands, straps, supports or stays for rainwater, hook and pintle hinges, clamps, hold fasts, wall ties, hooks for hanging fans, gusset plates, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick trapezoidal pattern of any colour having tensile strength of 550 MPa as in roof covering, fixed with self tapping screws complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to a distance n. exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for hard core of broken stone aggregate of guage not exc 63 mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
M/s D K Sharma
Pushkar Dutt Bhatt
SHAHJEE FRIDGE SERVICE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .