Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 CrAccepted-Finance | ₹1.4 Cr | L-1 | Accepted-Finance 1st lowest bidder. |
| 2 | L-2₹1.4 CrAccepted-Finance | ₹1.4 Cr | L-2 | Accepted-Finance 2nd lowest bidder. |
| 3 | L-3₹1.5 CrAccepted-Finance | ₹1.5 Cr | L-3 | Accepted-Finance 3rd lowest bidder. |
| 4 | L-4₹1.5 CrAccepted-Finance | ₹1.5 Cr | L-4 | Accepted-Finance 4th lowest bidder. |
| 5 | L-5₹1.6 CrAccepted-Finance | ₹1.6 Cr | L-5 | Accepted-Finance 5th lowest bidder. |
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
2 Feb 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer, PWD Division M-413, Under Ring Road Bypass Flyover, Opp. IGI Stadium Gate No. 09, New Delhi-110002
Construction of Under Ground Sump Well of 16 Lakh Litre Capacity at ITO Pump House under Sub Division - 3 of Division C and ND - Roads (M-413) during 2025-26.
2026_PWD_285595_1
41/SE/C and ND/PWD/2025-26
Open Tender
Civil Works
120 days
Sub. Division-3
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹4.0 L
9 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls 4.6.1 Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :
Red sand stone - Exposed face machine cut and table rubbed with rough backing. 30 mm thick
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
12 mm cement plaster of mix :
1:4 (1 cement: 4 coarse sand)
6 mm cement plaster of mix :
1:3 (1 cement: 3 fine sand)
Neat cement punning
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :.
Two or more coats on new work
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
H D - 20 Circular shape 560 mm internal diameter
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
Using rough Kota stone
Modification Estimated Cost after using correction factor on DSR 2023 on account of GST @ 0.973
Add Cost Index @ 3.00% on DSR Items
Carrying out subsurface survey at above mentioned across the road showing Water supply Pipelines, Sewer lines, Telecom Cables, Communication lines, drains, Gas Pipe Lines, Anchors, Oil Pipe Lines, Electric Cables, & other conduits etc. in the proposed corridor along with providing depth and dimensional details of Underground utilities and mapping as per sub surface utility Engineering-SUE ASCE 3802 & INDS TT :401-2018 (Indian Society for Trenchless Technology).
Dewatering of pits or ground by dewatering pump , inclusive of all consumables, diesel oil, petrol, and lubricants etc. and disposal of water in all type of soils.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.17 MB
BOQ_377968.xls
BOQ • 0.33 MB
NIT.pdf
Tender Documents • 4.15 MB
Download all tender documents and submit your bid