| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.1 Cr+₹3.7 L (3.60%)Rejected-Finance | ₹1.1 Cr+₹3.7 L (3.60%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.1 Cr+₹7.3 L (7.14%)Rejected-Finance | ₹1.1 Cr+₹7.3 L (7.14%) | L3 | Rejected-Finance Rejected |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
25 Oct 2021, 12:00 pmClosed
SUPRINTENDENT ENGINEER RWD CIRCLE PITHORAGARH
SUPRINTENDENT ENGINEER RWD CIRCLE PITHORAGARH TAKANA
RAJKIY INTER COLLAGE NACHNI BULDING NIRMAN AT NACHNI
2021_RES_37159_2
769/2-Lekha/Nivida/2021-22 Dated 06-10-2021
Open Tender
Civil Works - Buildings
Item Rate
365 days
NACHNI
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Yes
EE RWD DIVISION PITHORAGARH
₹2.4 L
Yes
19 Sept 2023
8 Oct 2021
26 Oct 2021
8 Oct 2021
25 Oct 2021
8 Oct 2021
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level 1:5:10 (1 Cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing upto floor five level precast cement concrete solid block including hoisting and setting in position with cement mortar 1:5 (1 cement: 5 coarse sand), cost of required centring, shuttering and finishing exposed surfaces complete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and laying cement concrete in plain window sills, fillets etc upto floor five level, excluding the cost of centring, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shap wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge.
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-incharge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
12 mm cement plaster of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. 40mm thick with 20mm nominal size stone aggregate. complete.by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick.
Structural steel work riveted, bolted or welded in built kilogram up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete Fixed to steel windows by welding. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing panelled or panelled and glazed shutters for d and clerestory windows including ISI marked black enamelled M.S necessary screws excluding panelling which will be paid for separa 30 mm thick shutters
windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm.With 12 mm mild steel U beading. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm.
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Colour washing such as green, blue or buff to give an even shade New work (two or more coats) with a base coat of white washing with lime as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm).
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st conforming to IS :15622 of approved make in all colours, shades, exceptquality laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (75 mm diameter )
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (110 mm diameter )
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item Coupler 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved each design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete. 110 mm. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing to the inlet mouth of rain water pipe each cast iron grating 15 cm diameter and weighing not less than 440 grams. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing ball valve (brass) of approved quality complete. High or low pressure with plastic floats. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given 20 mm nominal bore
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. as per direction of Engineer -in- charge, work to be execuated as per specification a rate of above given (Flexible pipe 32mm dia)
Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall -Iinternal work 15 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work) 20 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W, pipe .
Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing square-mouth S.W. gully trap grade 'A'' complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With F.P.S. Bricks class designation 75 as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finished with a floating coat of neat cement complete as per standard design : as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given (With F.P.S. bricks)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Excavation in soil in Hilly Area by manual means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5m and a lead upto 20 m as per drawing and Technical Specification Clause 1603.1.
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Random Rubble Masonary laid dry in breast wall,retaining wall, parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications) as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item .
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 120 ,(Nominal mix 1:3.6 (Hand mixing)
GDS INFRASTRUCTURE
KAILASH CHANDRA UPRETI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .