Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹70.5 L+₹10.9 L (18.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹60.7 L+₹1.2 L (1.97%)Rejected-Finance VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹63.8 L+₹4.3 L (7.14%)Rejected-Finance D 2 ABHILASHA APARTMENT 11 A PURULIA ROAD RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹64.9 L
EMD Value
₹1.2 L
Closing Date
13 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Ranchi
HQ CWE RANCHI DIPATOLI CANTT
SPL REPAIR TO BLDG NO T4 T5 T6 OTM AT RAMGARH CANTT
2022_MES_516877_1
80599/1403/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH
As per tender documents
5 documents required · 5 mandatory
₹1,000
GE Ramgarh
₹1.2 L
Yes
HQ CWE RANCHI
4 Jul 2022
8 Apr 2022
19 May 2022
8 Apr 2022
13 May 2022
29 Apr 2022
8 Apr 2022 - 18 Apr 2022
18 Apr 2022
60 days
Amount
Dismantling of AC sheet (corrugated or semi corrugated) including AC ridges as in roof covering complete all as directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as diredcted.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as diredcted.
Dismantling wrought iorn or mild steel work of any description complete all as specified and as directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., and welding counter shunk for holes and necessary gusset plates etc., and similar work conforming to Fe-410-W (Gde E-250 quality A) complete all as directed by.
Preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of aluminium paint. Complete all as directed.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of aluminium paint over a coat red oxide primer complete all as directed.
Dismantling wall and ceiling boarding of any descripion , thickness including. cover fillets complete all as directed..
Dismantling of wooden scantling 40sqcm and over in section fixed in any position as in unframed work complete all as directed.
Dismantling of wooden fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section complete all as directed.
Aluminium snap grid frame work for false ceiling of size 605 mm X 605 mm ,using main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX36.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers complete all as directed.
S&F Non asbestos fibre cement building board 4 mm thick in ceiling fixed or laid/inserted to timber /GI/Aluminium frame work with screw complete all as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as directed.
Brick work with sub classification 7.5 ‘B’ bricks (old size) straight or curved plan exc 6 M mean radius built in CM (1:6) complete all as directed.
Taking down cement or cement lime plaster at any position including raking out joints, hacking for key and scrubbing down with water complete all as directed.
10mm thick rendering on fair faces of brick work/concrete surface in CM (1:6) surface finished fair & smooth without using extra cement complete all as directed.
15mm thick rendering on other than fair faces of brick work/concrete surface in CM (1:4) surface finished even & fair without using extra cement mixed with WPC as per manufacturer's instruction complete all as directed. Note:- WPC shall be measured and paid separately under relevant item
Supply only water proofing compound (liquid),ISI marked complete all as directed.
Preparation of new plastered surfaces of wall and applying two coats of white wall care putty (Each coat shall be minimum 1mm thick) to make entire surface free from undulations all as directed.
Preparing New putty wall surfaces and applying two coats of oil bound distemper over a coat of primer on walls surfaces complete all as directed.
Preparation of old surfaces of walls including washing, rubbing down and stopping of distempered surface and applying one coat of distemper oil emulsion on old decorated surface of wall complete all as directed.
Three coats of white wash including preparation of newly plastered surfaces on wall complete all as directed.
Two coats of white wash including preparation of old plastered surfaces on wall complete all as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premices complete all as directed.
Cement concrete (1:2:4), type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, coping, window cill etc complete all as directed.
Joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM (1:6), set & jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tiles complete complete all as directed.
All as per item No 26 here in before but with glazed tiles on vertical surface such as skirting/ risers including 10mm thick rendering in CM (1:4) complete all as directed.
Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc complete all as directed.
Machine cut kota stone slab flooring 16-18 mm thick over & including 20mm screed base in CM (1: 4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
All as per above Item No. 29 here in before but as in Skirting with 10mm thick rendering in CM (1:3)
16-18mm thick white Marble stone flooring as in border,etc at kota stone flooring over 20mm screed base in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
Taking down chaukhat with shutter (without taking of shutter from the frame) of any description n.exc 1.5 sqm each complete as directed.
Ditto all as per item No 32 here in before but exc 1.5 sqm but not exc 4 sqm
Pressed steel frame of size 165mm x 60 mm x 1.25mm for door with one or more rebates or single /double shutter including necessary fixing lugs,hinges ,iron strike plate etc with and including PCC(1:3:6) type B0 using 12.5 mm graded stone aggregate filling in hollow portion of frame complete all as directed.
Chowkhat 2nd class hard wood wrought , framed rebated on the solid, rounded or chamfered , put together with glue pinned at joints complete all as directed.
30 mm thick flush shutter solid core construction with block board core and ply wood face pannels commercial type on decorative face veneer both face with lipping/ frame complete all as directed.
35mm thick 2nd class hardwood glazed and skeleton shutters of 8 panels, divided into squares with plain, chamfered or rounded, mitred & rebated sash bars and prepared to receive glass, gauze etc edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkats for doors, etc complete, size of member of shutter as specified in SSR Part -I, Sec 8, clause 8.24 (a) complete all as directed.
30mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain chamfered or rounded fitted with cat and mitred beads for securing glass etc fitted to chowkats for windows, ventilators,etc complete, size of member of shutter as specified in SSR Part -I, Sec 8, clause 8.24 (b) complete all as directed.
Mild steel flat iron Fe-290 gde E -165 work as in hold fast including all nesessary cutting etc complete all as directed.
3mm thick plain sheet glass ordinary quality & glazing with oil putty n.exc 0.50 Sqm in each pane complete all as directed.
Stain less steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, wooden fillet & beds complete all as directed.
Galvanised mild steel wire cloth (as in repair), 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples fixed to wooden fillet & beads complete all as directed.
Aluminium anodised barrel tower bolt extruded section and fixed of size 200mm complete all as directed.
Aluminium anodised barrel tower bolt extruded section and fixed of size 125mm complete all as directed.
150mm long aluminium handles cast type, anodised complete all as directed.
125mm long aluminium handles cast type, anodised complete all as directed.
Mild steel butt hinges 100 mm long with galvanised mild steel hinge pin anodised and fixed complete all as directed.
Mild steel butt hinges 75 mm long with galvanised mild steel hinge pin anodised and fixed complete all as directed.
Aluminium 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or aluminium alloy and fixed complete all as directed.
Painting on new wooden based surfaces of any description not other wise described over 10cm width or girth applying two coat synthetic enamel paint over one coat of pink primer including preparation of surfaces complete all as directed .
Demoliton of cement concrete in ground floor paving n exc 15cm thickness ( below or above ground level ) complete all as directed.
75 mm thick PCC type C1 (1:3:6), (using 20mm graded stone aggregate) as in plinth protection, finished even and fair without using extra cement including 10 mm wide groove not exc 3.00 mtr in length , filled the groove with mastic complete all as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed.
Point wiring in PVC casing caping with multi stranded FRLS copper conductor cable of size 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated multistranded FRLS cable of size 1.5 Sqmm as earth continuity conductor for One light/fan point/Exhaust fan point controlled by one way switch 5 Apms. complete all as directed Note : Proper colour coding to be adopted.
All as per item no 54 above but for One 5 Amps socket outlet on same board.
All as per item no 54 above but for One 5 Amps socket outlet on independent board.
Point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated multistranded FRLS fire retardant cable of size 2.5 Sqmm as earth continuity conductor. complete all as directed. Note : Proper colour coding to be adopted.
Switch piano flush button single pole one way 5 Amps, complete all as directed.
Socket outlet 2 in1, 3 pin,5 Amps flush type,universsal complete all as directed.
Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal, complete all as directed.
Switch socket combination 2 in1, 3 pin,5 Amps flush type,universsal complete all as directed.
Ceiling rose 3 terminals PVC/Polycarbonate, isolated body, ISI marked complete all as directed.
Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as directed.
LED bulb of capacity 15 watts lumen out put (500) length 102 mm dia 56 mm base cap B22, (ISI marked) complete with all accessories base (ISI marked) all as directed.
Retro type LED lights fitting 1x 22 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed.
LED light fitting 1x 9W/1x 10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 8 way with IP-43 IK-09 protection incl. 200 Amp bus bar and neutral link (ISI marked) complete all as directed.
Miniature circuit breaker (MCB) of SPN 32 AMP current carrying capacity 240 V, 10 KA, 'C' Curve in the MCB DB complete with connection testing and commissioning complete all as directed.
Miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity 240V, 10 KA, 'C' curue in the MCB DB complete with connection testing and commissioning. complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as directed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as directed.
Sub main wiring along with earth wire with FRLS PVC insulated copper conductor, single core multistranded cable in concealed suitable size of PVC Conduit with 2x4.0 sq mm+1x4.0 sqmm earth wire.
Supply , laying commissioning & testing1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed 25 sq mm 2 core nominal cross section complete all as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and getting out in soft / loose soil complete all as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as directed.
Reinforced pre cast concrete cable cover class LV, Type - 1 , flat, size 250 mm x 150 mm x 40 mm complete all as directed.
Sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand all as directed. (Note : The depth of sand shall be measured after punning only)
GI pipe 50 mm dia light grade with all necessary fittings for cable protection complete all as directed.
M/S AMOD KUMAR PANDEY
M/S ROHIT CONSTUCTION
M/S SWASTIK HI-TECH BUILDERS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .