Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | ₹1.2 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹1.3 Cr+₹1.9 L (1.57%)Rejected-AOC 1A 1ST FLOOR BLOCK 1 SHRISTI DHARMESHWAR APPARTMENT DINESH OJHA PATH RAJGARH ROAD GUWAHATI 781005 | KAMRUP METRO | ASSAM | 781005 | ₹1.3 Cr+₹1.9 L (1.57%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
25 Jul 2022, 2:00 pmClosed
Addl. CE, PWD (Planning), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Oxygen Generation Plant 1000 LMP capacity 2 Nos. (Constructed DRDO) at Silchar Medical College and Hospital, Silchar (Providing Medical gas pipe line, security brick boundary wall alongwith 2 (two) Nos. Iron gate and External Electrif
2022_PWBNH_26251_1
CE/TB-III/60/2022/2 PMCARE-DRDO-SMCH
Open Tender
Civil Works - Building
Item Rate
30 days
Silchar
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,314
₹2.3 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
1 Nov 2022
7 Jul 2022
26 Jul 2022
7 Jul 2022
25 Jul 2022
15 Jul 2022
12 Jul 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Electric resistance or induction butt welded tubes
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement 18 mm thick
CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Medical gas pipe line Copper Pipe As Per Medical Grade v) 42mm OD x 1.2mm Thick
Supply, Installation, Testing & Commissioning of Isolation Valves with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed for the following Isolation Valves:- 42mm OD
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (7.1.1) Upto 35 sq. mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
SUB-STATION EQUIPMENT (6.2.1) Supplying, installation , testing &commissioning of 33KV/0.433 Kv or 11 Kv/0.433 Kv Sub-station equipment comprising HT panel, dry type/Oil type transformers, HT cable, bus trunking from transformer to LT panel, LT panels, automatic power factor correction panel, active harmonic filters, TVSS( transient voltage supperession system). SPD (Surge protection system), essential panel, earthing, required inter-connections, sub-station safety equipments including LT cabling from substation to the buildings fed by the substation
Generating Sets. (6.3.1) Supplying, Installation , testing & commissioning of D.G. sets, AMF panel, bus ducting/ cables from DG sets to essential panel, DG set enclose room sound insulation/ventilation/smoke excuhst as reqd., earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/exhaust piping/exhaust chimney as per CPCB norms, civil works connected with D.G. sets including foundation as reqd.
SWARAJ INFRA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .