Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Not Admitted-Fee/PreQual/Technical VILLAGE VILLAGE TEHSIL BAIJNATH DISTRICT KANGRA | MANDI | HIMACHAL PRADESH | 175013 | Not Admitted-Fee/PreQual/Technical Others-ONLY TWO BIDDERS QUALIFIED |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical O O SDSCO PALAMPUR PALAMPUR DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 176001 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical HIMACHAL PRADESH | Not Admitted-Fee/PreQual/Technical Others-ONLY TWO BIDDERS QUALIFIED |
Tender Value
₹1.3 Cr
EMD Value
₹1.7 L
Closing Date
5 Jan 2026, 5:00 pmClosed
District Project Manager HPCDP JICA ODA
District Project Management Unit HPCDP JICA ODA Phase-II, Opposite to Soil Testing Lab, Holta at Palampur
C/o Flow Irrigation Scheme Rori Kori, Village- Rori Kori, G.P. Rori Kori, Tehsil Dadasiba, District-Kangra (H.P.)
2025_HPCDP_124477_1
No.AGR. DPMU. KGR. F (7) Tender/13/2022-3254
Open Tender
Civil Works
Item Rate
365 days
G.P. Rori Kori, Tehsil Dadasiba, District-Kangra
Please refer Tender documents.
16 documents required · 16 mandatory
₹5,000
₹1.7 L
District Project Manager HPCDP JICA ODA
10 Feb 2026
26 Dec 2025
6 Jan 2026
26 Dec 2025
5 Jan 2026
26 Dec 2025
29 Dec 2025
Clearance of silt/malwa from channel including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 mtr complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Demolishing of cement concrete manually/ by mechanical means including disposal of material within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation, trenches or drains, pits upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, chieselling soft / hard rock including getting out the excavated soil, dressing of sides, ramming of bottoms and returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavating trenches of required width for pipes, cables, etc including excavating for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed, within a lead of 50m. pipes, cables etc. exceeding 80mm dia. but not exceeding 300mm dia. complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge.
Foundation footings bases of columns etc complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Edges of slabs and breaks in floors and walls under 20 cm wide complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Suspended floors, roofs, landing, balconies and access platform, complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
In Sides complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Side Slopes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
All work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
All work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In beams, suspended floors, roofs, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above olinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:1:2 (1cement : 1 sand : 2 graded stone aggregate 20 mm nominal size) and curing complete in and excluding cost of form work in foundation and plinth complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:1:2 (1cement : 1 sand : 2 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in walls including attached buttress pilasters and thire caps basis and string courses etc. upto floor two level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing arrangments for air ventilation in top RCC Slab complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing in position pre-cast RCC manhole cover and frame of required shape and approved quality MD-10 circular shape 600 mm internal dimensions complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing ISI marked oxidised M.S Handle conforming to IS:4992 with necessary screws ect 125 mm complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Writing new letters and figures of any shade with synthetic enamel black or any other approved colour to give an even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing, laying, jointing, testing & commissioning at site in trenches bevelled ended BIS marked MSERW pipes 300 mm dia of various grade conforming to IS/ISO-3183-2012 L260 or X42 or its equivalent specifications latest with upto date amendments of following dia with upto date amendments having wall thickness and per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code in random lengths of 6 to 7 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge. The pipe shall haves zinc coating inside & out side conforming to IS/ISO-4736-1986 or latest with upto date amendments & shall be engraved with code IS/ISO-3183-2012 or its equivalent. The laying shall conform to BIS 5822-1970 or latest with upto date amendments with provision of scour pipe after every km by providing Tee & Sluice valve etc. complete to the entire satisfaction of Engineer-in-charge (Earth work shall be measured and paid for separately).
Providing, laying, jointing, testing & commissioning at site in trenches bevelled ended BIS marked MSERW pipes 250 mm dia of various grade conforming to IS/ISO-3183-2012 L260 or X42 or its equivalent specifications latest with upto date amendments of following dia with upto date amendments having wall thickness and per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code in random lengths of 6 to 7 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge. The pipe shall haves zinc coating inside & out side conforming to IS/ISO-4736-1986 or latest with upto date amendments & shall be engraved with code IS/ISO-3183-2012 or its equivalent. The laying shall conform to BIS 5822-1970 or latest with upto date amendments with provision of scour pipe after every km by providing Tee & Sluice valve etc. complete to the entire satisfaction of Engineer-in-charge (Earth work shall be measured and paid for separately).
Flange Table-5 300 MM
Flange Table-5 250 MM
Restoration charges for road crossing as per HPPWD Norms for digging of metalled & Tarred road with bitument complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge..
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.82 MB
BIDRORIKORI.pdf
Tender Documents • 1.47 MB
BOQ_182953.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .