| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC Contract Awarded | |
| 2 | L2₹3.5 L+₹47,256 (15.9%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹3.6 L+₹60,296 (20.2%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹3.8 L+₹85,996 (28.9%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹3.9 L+₹88,606 (29.7%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹4.4 L
EMD Value
₹8,800
Closing Date
18 Sept 2023, 6:00 pmClosed
AGE (I) RnD Haldwani
AGE (I) RnD Haldwani PO Arjunpur UK 263139
REPAIR / SERVING OF SPLIT ACs, WINDOW ACs, WATER COOLER, REFRIGERATOR, DESERT COOLER ETC AT DIBER HALDWANI
2023_MES_615033_1
AGE (I)/RnD/HLD-27 OF 2023-2024
Open Tender
Civil Works
Item Rate
270 days
DIBER Haldwani
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) RnD Haldwani
₹8,800
Yes
25 Oct 2023
22 Aug 2023
20 Sept 2023
22 Aug 2023
18 Sept 2023
5 Sept 2023
Amount
Contract Details
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position working upto five storey building, strip opening for servicing and maintanance of Split AC 1.5/2.0 ton capacity complete indoor/outdoor unit for routine check up for smoth functioning, checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical/electronic circuit, functioning of remote, functioning cooling system, cleaning and servicing of the AC with using liquid caustic soda/detergent solution, cleaning of suction air filter, cooling coil,condenser coil, blower motor, fan motor, brazing the discharge and suction line, complete indoor/out door unit, reassembling, fixing and testing of the AC complete all as specified and directed. by Engr-in-charge. Note: The replacement of defective / non functional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’.
Disconnecting, dismantling and taking out the existing Air conditioner Window type of any description, any make and in any position working upto five storey building, strip opening for servicing and maintanance of Window AC 1.5/2.0 ton capacity for routine check up for smoth functioning, checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical/electronic circuit, functioning of remote, functioning cooling system, cleaning and servicing of the AC with using liquid caustic soda/detergent solution, cleaning of suction air filter, cooling coil,condenser coil, blower motor, fan motor, brazing the discharge and suction line, complete unit, reassembling, fixing and testing of the AC complete all as specified and directed. by Engr-in-charge. Note: Spares required will be measured and paid separately. Note: The replacement of defective / non functional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’.
Taking out existing burnt / unserviceable compressor unit from 1.5 ton capacity of window/split type air conditioner and replacing the same with factory built hermetically sealed rotary compressor unit including necessary accessories and mounting materials, welding, leak testing by charging with CO2/dry nitrogen gas. Evacuating the system and charging of R-22 Refrigerant gas after ensure leak proof condition and testing complete all as directed by Engineer-in-Charge etc. Make - Godrej/Techmesh/Blue star/Hitachi. Note - Refrigerant gas shall be measured and paid separately.
All as per item No 4 here-in- before but of capacity 2.0 ton
Taking Down of existing damaged / burnt blower motor from split/window AC and supply & fixing of new blower motor with capacitor & mounting materials single phase, 230 Volts 50 Hz suitable for 1.5 ton & 2 ton capacity of window/Split type AC
Taking out the defective thermo static switch, supply and fix new thermostatic switch for 1.5/2 ton window/split type AC
Disconnecting and taking out defective / nonfunctional relay contactor and Supply & fixing relay contactor suitable for Split A/C 1.5/2.0 Ton capacity complete all as specified and directed.
Taking out defective / non functional fan motor capacitor and Supply & fixing of fan motor capacitor of existing capacity 2.5 MFD to 4.0 MFD for Window A/C 1.5/2.0 Ton capacity complete all as specified and directed.
Taking out existing damaged air filter pad. Supply and fix new air filter pad of existing size of 1.5/2 ton window/split type AC
Taking out the existing defective starting capacitor, supply and fix new starting capacitor of existing capacity upto 60 MFD suitable for 1.5 ton & 2 ton window/split type AC.
Taking out damaged fan blade from window/split AC 1.5/2 ton. Supply & fix new PVC fan blade of existing size and rotation suitable for 1.5/2 ton window/split type AC
Taking out the unserviceable fan motor, supply and fix new fan motor suitable for 1.5/2.0 ton window/split type AC
Taking out the existing mounting rubber ring, supply and fix new mounting rubber ring for fan motor / compressor etc as per existing size/type suitable for 1.5/2.0 ton window/split type AC
M&L for charging of refrigerant gas R-22 in Split/Window AC 1.5/2.0 Ton capacity including cost of leakage detection, welding, and refitting the same in entire system as required, including replacing defective liquid strainer, capillary tube and testing complete all as directed by Engineer-in-Charge. Note: However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item .
M&L for taking out unserviceable PCB unit from split/window AC 1.5/2.0 capacity and replace the burnt unserviceable electronic parts, refixing the same after repair and testing its proper function all as directed by Engr -In - Charge
M&L for taking out unserviceable burnt PCB unit from split/Window type AC and supply and fixing new PCB unit suitable for existing Split/window AC 1.5/2.0 Ton capacity
M&L for front grill suitable for window type AC 1.5/2.0 Ton as per existing size .
S&F PVC insulated and round sheathed multi core industrial cable 4 sq mm 3 core copper conductor heavy duty 1100 volt grade
Taking out unserviceable swing motor from split AC indoor unit and supply and fixing new swing motor suitable for 1.5/2.0 Ton split AC
Taking out unserviceable existing cooling coil from window/split AC of 1.5/2.0 ton capacity and supply and fixing of new cooling coil with thermostat complete all as directed
Taking out existing burnt / unserviceable compressor unit from water cooler & replacing the same with factory built hermetically sealed rotary compressor unit including necessary accessories and maintaining material, welding, leak testing by dry Nitrogen gas and charging R-134A refrigerant gas after ensuring leak proof condition and testing of water cooler 40 / 80 ltrs capacity all as directed by Engineer-in-Charge
Taking out defective / unserviceable relay contractor , supply and fixing of relay contractor suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable starting capacitor , supply and fixing of starting capacitor suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable fan motor capacitor , supply and fixing of fan motor capacitor suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable over load protector , supply and fixing of over load protector suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable thermostatic switch , supply and fixing of thermostatic switch suitable for water cooler of capacity 40 / 80 ltrs
Taking out old unserviceable chromium plated push cock / lifting cock of 15 mm dia , supply and fixing of chromium plated push cock / lifting cock of 15 mm dia suitable for water cooler of capacity 40 / 80 ltrs
Taking out unserviceable PVC connection pipe, supply and fixing of PVC connection pipe 15 mm dia 450 mtr long suitable for water cooler of capacity 40 / 80 ltrs
Supply and charging of refrigerant R-134A including cost of welding, leak detection and rectification in the entire system with replacement of liquid strainer and capillary tube including testing of water cooler of capacity 40 / 80 ltrs all as directed by Engineer-in-charge.
Taking out defective / burnt auto transformer. Supply and replacement of new auto transformer of voltage stabiliser 4 KVA / 5 KVA capacity
Taking out defective / burnt auto transformer. Supply and replacement of new auto transformer of voltage stabiliser 3 KVA capacity
Taking out defective PCB (Printed Circuit Board) complete with components. Supply and replacement of new PCB complete with components of capacity 4 KVA / 5 KVA Voltage stabiliser
Taking out defective PCB (Printed Circuit Board) complete with components. Supply and replacement of new PCB complete with components of capacity 3 KVA Voltage stabiliser
Taking out faulty relay. Supply and replacement of new relay for voltage stabiliser upto 5.0 KVA capacity
Supply and grouting MS anchor fastener heavy duty 12 mm dia 10 cm long with complete accessories all as directed.
Supply and fixing of 3 pin plug top 15 Amps including taking out old u/s plug top
S&F mounting bracket of Split AC out door unit suitable for fixing of 1.5/2.0 Ton AC on wall surface upto 5 storey building, heavy duty including mounting accessories such as MS fastener, nuts, bolts, washers, etc complete all as specified and directed by Engr-in- Charge
Supply & fixing of PVC flexible drain water pipe suitable for window/split AC standard size of 3 meter long complete all as specified and directed.
Supply and fixing of 20 mm dia medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Supply and fixing of 25 mm dia medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp including taking out old unserviceable plug complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Servicing of desert cooler of different size and capacity including cleaning ,greasing, painting of whole body inner and outer ( inner body should be painted by red oxide paint , the joints and corner should be filled by black bituminius paint, the outer body should be painted by sky blue paint,) The minor parts such as nut bolts and washer is deemed in the quated rate and should be tightned and fastned properly.
Taking out & removing old burnt-out windings of Desert cooler fan motor of any description and servicing/rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site and re- assembling the complete, connecting and testing on full load to the entire satisfaction of Engineer-in-charge.
Supply & fixing of new wood pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.
Supply and fixing of submersible pump for Desert cooler 230 volts, 45 watt, 1400 RPM, with ball bearings complete all as specified and directed (Make : Crompton / AUE / Khaitan/ Bajaj )
Material and labour for fabrication of iron frame work suitable for mounting of Window AC/ Desert cooler fixed on wall made out of mild steel fe 410 W grade E-250 quality chanels angels including necessary welding, cutting, bending, railing and suitable size of MS fastener, nuts, bolts, washers, etc as required at site with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer after completion of fabrication work complete all as specified and directed
AJA BUILDERS
U P ENTERPRISES
M/S BHATT ENTERPRISES
JAGAT POWER ELCTRICAL
om enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .