Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.0 Cr+₹49.5 L (10.9%)Rejected-AOC | ₹5.0 Cr+₹49.5 L (10.9%) | L2 | Rejected-AOC L2 |
| 3 | L3₹5.9 Cr+₹1.4 Cr (30.4%)Rejected-Finance | ₹5.9 Cr+₹1.4 Cr (30.4%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹4.8 Cr
EMD Value
₹1 L
Closing Date
11 Nov 2022, 5:00 pmClosed
Managing Director KPHCC
KERALA POLICE HOUSING AND CONSTRUCTION CORPORATION LTD CHANDRASEKHARAN NAIR STADIUM, PALAYAM, THIRUVANANTHAPURAM - 695033
Repair and Maintenance of proposed IMFL building MDL, Menonpara Palakkad (Re)
2022_KPHCC_524230_1
NIT No.114/KPHCC/2022-23
Open Tender
Civil Works - Buildings
Item Rate
180 days
Menonpara Palakkad
Please refer Tender documents.
8 documents required · 8 mandatory
₹8,850
₹1 L
12 Dec 2022
3 Nov 2022
14 Nov 2022
3 Nov 2022
11 Nov 2022
3 Nov 2022
3 Nov 2022 - 11 Nov 2022
Amount
CIVIL WORK
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth
od107600/2022_2023 : Site clearance using JCB
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
15.12.2 : Of area beyond 3 sq. metres
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
15.28.2 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
od131952/2022_2023 : Leak proofing of asbestos sheet using damber sheet- APP membrane etc. of approved standards and tested in accordance with ASTM D-5147 providing laying preparation of surface etc. included upto 16m height building.
od131953/2022_2023 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
od145497/2022_2023 : Providing asbestos corrugated sheets roofing up to any pitch and fixing with polymer coated J,or L hooks, bolts and nuts 8 mm dia. G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. (Asbestos corrugated sheet availabe from site)
12.9 : Extra for straight cutting in non - asbestos polypropylene reinforced cement corrugated, semi-corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc.Extra for straight cutting in no - asbestos polypropylene reinforced cement corrugate, semi-corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc.
12.12.1 : Providing and fixing ridges and hips in non-asbestos fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.Corrugated serrated adjustable ridges
12.41.2 : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
12.42.5.2 : Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.5<sup>0</sup>110 mm bend
12.42.6.2 : Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionShoe (Plain)110 mm Shoe
12.43.2 : Providing and fixing unplasticised- PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
12.46 : Providing and fixing to the inlet mouth of rain water pipe PTMT ( an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms
15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness
26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter
26.32.1 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.
14.83 : Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
od133042/2022_2023 : Scrubbing, scrapping, cleaning, sandpapering and preparing the surfcae of Asbestos/ Non-Asbestos polypropylene sheets and painting the same with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :(one or more coats)
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
od154319/2022_2023 : Providing and fixing scaffolding system on the building/structure, upto 20 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with M.S. tube, horizontal & vertical tubes joint with proper lock system and staircase system in the scaffolding for working platform etc., maintaining it in a serviceable condition for execution of all work and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
14.4.1 : Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground.For door / window / clerestory window
14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead.
6.3.1 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks
6.40 : Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor V level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
10.11.1 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.2 : Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :5.5 mm thick glass panes
21.5 : Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
21.6 : Providing and fixing 6 mm dia. G I level adjusting hangers ( upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-Charge.
50.12.4.2 : Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area
od133208/2022_2023 : Providing and fixing hard drawn steel/iron wire fabric 35x35 mm mesh of dia 3.5mm to existing frames etc. with 12mm steel beading priming coat with approved steel primer all complete.
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
$Electrical Works
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.32 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mm
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.
od121382/2022_2023 : Supply and Fixing 32 A DP switch with indicator modular in the existing GI box and giving connections as required.
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.3 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
od121383/2022_2023 : Supply and providing 4U cabinet of approved make powder coated with glass panel front door including giving connection etc complete as required.
od121384/2022_2023 : Supply,marking,crimping RJ45 connectors /sockets and fixing to the existing enclosure and giving connection etc complete
od121385/2022_2023 : Supply and providing Cat 6 Input/Out put Modular socket with plate on surface
od121388/2022_2023 : Supply installation testing and commissioning of 100W LED Top light with<br>complete set (group-A) Govt approved and reputed brands on 25 mm or nearest suitable size B class GI pipe 1.5 M long cut and weld,bend to shape fixed on wall using flat iron clamps fabricated frpm 25x3 mm MS flat giving connection with required length of 24/.20mm PVC insulated and PVC sheathed 650 /1100V grade round 3 core copper conductor conforming to relavant ISS painting the GI pipe and clamps with all necessary items making good the surface as required
od121389/2022_2023 : Supply of ISI marked 2 HP 28 stage single phase submersible pumpset suitable for 150mm dia bore well inclusive of cost and conveyance etc excluding panel board.
od121390/2022_2023 : Supply and drawing PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4sqmm
od121391/2022_2023 : Supply and fixing of 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C. make Havells or equivalent
od121396/2022_2023 : Supply and fixing of 19" 15U wall mount rack for switches with cable manager and hardware mounting kit. Accepted make; Valrack, Netrack, President, HCL or equivalent.
od121397/2022_2023 : Providing 3 meter length patch chord
od121398/2022_2023 : Providing patch panel
od126468/2022_2023 : Supply of 20W LED tube light fitting have 2000lumen with duly wired up for use on 230 V AC. The fittings shall be directly on ceiling/ wall, including all accessories etc. as required. Make -Philips or equivalent.
od131361/2022_2023 : Supply and Fixing Recess type ceiling light 18 W LED panel light fitting make Luker/Bajaj/Crompton/Philips or equivalant govt approved brand including connection etc as complete
od126469/2022_2023 : Supply of the following sizes of industrial type exhaust fans in the existing<br>opening, conforming to relevant ISS. Size - 18 Inch ( 457 mm )metal frame, 1400<br>rpm.
od126470/2022_2023 : Supply and Fixing 32 A DP switch with indicator modular in the existing GI box and giving connections as required.
od126471/2022_2023 : Supply and install Up&Down IP65 water resistant AC 140V-260 V Aluminium Die Cast body Outdoor wall lights 2X3W
od121399/2022_2023 : Supply and fixing casing and capping of reputed brand (Legrand/ precesion/ pressfit) with ISI mark -20mm<br>
od121400/2022_2023 : Supply and fixing casing and capping of reputed brand (Legrand/ precesion/ pressfit) with ISI mark- 25mm<br>
od121401/2022_2023 : Labour charges for dismantling existing switchboards, fittings etc and re- fitting if necessary,giving connections etc complete etc as required.<br>
od121402/2022_2023 : Labour charges for dismantling existing switchboards, fittings etc and re- fitting if necessary,giving connections complete as required.<br>
od121403/2022_2023 : Supply installation testing and commissioning of 63A 4 pole ONLOAD COS, Havells and equal ant make with enclosure as required
od121406/2022_2023 : Supply,installation,testing and commisioning of following port switch (10/100/1000 mbps) 24 Port GIGABIT Desktop Switch D-Link/ TP-Link approved make,giving connections etc. complete as required.
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
GENERATOR+TRANSFORMER
od120646/2022_2023 : Supply and Installation of suitable dia Exhaust Pipe for 160 kVA DG Set
od120647/2022_2023 : Supply conveyance and installation of 160KVA DG set of approved make
od120648/2022_2023 : Supply and providing heat shrinkable termination kit for 3Cx300sq.mm HT cable Indoor Kit
od120649/2022_2023 : Supply and providing heat shrinkable termination kit for 3Cx300sq.mm HT cable Out door kit<br>
od120650/2022_2023 : Supply installation and commissioning of Unitised Sub Station-Indoor-with LBSM Panel-250 KVA 11KV/433V, 3 phase, vector DYN-11 transformer with offcircuit tappings from +5% to -10% in steps of 2.5%, changeable on offcircuit by tap links provided, with WTI & LV terminals suitable for 2 runs of PVCA cable and HV terminals connected to 11 KV, 26.2 KA, 630 A Load Break Switch, with incoming suitable for XLPE cable, with HT HRC fuses, 3 Nos CTs, 1 No PT, provision for fixing TOD Meter and output connected to 11KV seal off bushings to the transformer. Type:TRE.
od120651/2022_2023 : Supply and providing Plate Earthing as per IS 3043 with 1200x1200x10mm CI Earth Plate, 25 mm GI Watering pipe fixed to the earth plate with 25x3 mm Cu clamps, filling required quantity of earthing compound including excavation of Earth pit, construction of Earth pit inspection chamber. (For USS & DG
od120653/2022_2023 : Design, Fabrication, Supply, Erection,Testing and<br>commisioning of following cubicle type, fully<br>compartmentalised, dust tight, vermin proof, Panel board,<br>fabricated out of 16 SWG CRCA sheet powder coated with<br>Alumimium Busbars of suitable size, earth bus of adequate<br>capacity, double earth connection to all switches, internal<br>rigid connection etc. including suitable chambers, front open<br>with water proof shrouding, free standing panel consisting of<br>the following as per standards <br>SSB <br>Incomer - 160A TPN Isolator- 1 No<br>Outgoing<br>32A 4P MCCB- 2 Nos<br>63A 4P MCCB- 6 No<br>63A 4P MCCB- 2 Nos (Spare)<br>Metering & Indication<br>RYB Indication lamps with control MCBs- 1 Set<br>MFM with 150/5A CL:1 CT- 1 Set
od145192/2022_2023 : Design, Fabrication, Supply, Erection, Testing and commissioning of following cubicle type, fully compartmentalized, dust tight, vermin proof, Panel board, fabricated out of 16 SWG CRCA sheet powder coated with Aluminum Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open with water proof shrouding, free standing panel consisting of the following as per standards.<br>Utility Panel 1 No Incomer: 125A TPN Isolator- 1 No Outgoings: 63A 4P MCCB - 1 No 63A TPN Isolator - 1 No 32A 4P MCCB - 3 No 63A 4P MCCB - 1 No (Spare) Metering & Indication RYB Indication lamps with control MCBs- 1 Set MFM with 150/5A CL:1 CT- 1 Set
od145193/2022_2023 : Supply and installation of 40 KVAR APFC Panel etc as required
od120655/2022_2023 : Supply and Laying of 110mm dia HDPE Pipe
od120656/2022_2023 : Excavation of cable trench with 0.5m width and 1.2m depth
od120657/2022_2023 : Supply and installation of Metering cubicle for HT TOD Meter
od120658/2022_2023 : Supply and installation of Outdoor CT-PT unit with 3nos -/5, Cl:0.2S, 15VA CT and 1no. 11KV/110V, Cl:0.2, 25VA PT
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.5 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness
4.2.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required450 mm width X 50 mm depth X 2.0 mm thickness
90.6.5.5 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
90.6.5.19 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
90.6.5.20 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
90.12.2.38 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)
90.12.5.12 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.5.25 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.6.29 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.31 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.32 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.34 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.38 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.40 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.6.46 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.43 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
9.1.36 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm)
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)
od131368/2022_2023 : Charges for preparation of drawing, obtaining approval, Preparing completion report, arranging inspection and obtaining sanction order from Electrical Inspectorate.
od131369/2022_2023 : Supply and providing 50/5A, Cl:5P10, 15VA Neutral CT with box
od131370/2022_2023 : Charges for testing of CT/PT unit and TOD meter at TMR section including transportation (Statutory fee not in our scope)"<br>
WEIGH BRIDGE
od132755/2022_2023 : Supply installation and commissioning of fully electronic weighbridge construct the platform size of 9mtr x 3mtr capable of lift 60tonnes of weight accuracy required 10kg
LIGHTING ARRESTORS
od130381/2022_2023 : 5<br><br>Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 9m. It should be free from hazardous substances. The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 30KN. The dimension shall be 320mmx 320mmx 190mm. Govt approved Indian labs test certificate required. Make: Cape
od130382/2022_2023 : Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having100microns as per IS/IEC62305.Each under ground joints has to be wrapped with petrolatum coated chemical fiber fabric having 1.1mm thick and width 50mm.Govt approved Indian labs test certificate required. Make: Cape
od130383/2022_2023 : Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring<br>equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required. Make: Cape
od130384/2022_2023 : Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector:<br>using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the<br>requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required. Make: Cape
od130385/2022_2023 : Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC - 62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind<br>load needs to be considered. Govt approved Indian labs test certificate required. Make: Cape<br>b 4 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories
od130386/2022_2023 : Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC - 62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal.<br>Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec<br>waveform. This is required if using 17 KG stone supports.<br>Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind<br>load needs to be considered. Govt approved Indian labs test certificate required. Make: Cape<br>a. 3 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories
FIRE FIGHTING
od120604/2022_2023 : Supply and Installation 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit<br>light fixture with 1.3 AH 4hrs battery backup unit, LED Lamps, indicating Fire Exit, recess mounted type. 24 hrs x 7 days working conditional. MAKE: AGNI SURAKSHA(ASES)
od120605/2022_2023 : Supply and Installation of position the following type of sign boards made out of 2mm thick sign PVC with illuminated printing fasteners.<br>MAKE: PROLITE c. Fire Assembly Point {Size 150 x 300mm)
od120606/2022_2023 : Supply and Installation of position the following type of sign boards made out of 2mm thick sign PVC with illuminated printing fasteners.<br>MAKE: PROLITE b. EXIT {Size 150 x 300mm)
od120607/2022_2023 : Supply and Installation of position the following type of sign boards made out of 2mm thick sign PVC with illuminated printing fasteners.<br>MAKE: PROLITE a. Fire Pump Room {Size 100 x 300mm)
od120608/2022_2023 : Supply and installation of ABC type fire extinguisher of 4 kgs capacity complete with initial charges and installation brackets. Make :SAFEX
od120609/2022_2023 : Supply, Installation, Testing and Commissioning of Photo Electric Smoke Detector with Base. Make: GST/SYSTEM SENSOR
od120610/2022_2023 : Supply and install 1 Sq.mm PVC insulated multi stranded Copper wired cable.
od141147/2022_2023 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 X 1.00 sq.mm<br>
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
od120611/2022_2023 : Fire Alarm Panel: Supply and Installation of Microprocessor based Main Control Panel 10 Zones, with 160 watt amplifier including battery charging system, with all attachment for the alarm system with auto alert facilities and made up of steel enclosure of floor/wall mounting with lock, epoxy coated as per the fire standard requirement, including necessary battery backup. { 2x 12 V Batteries)Make: AGNI SURAKSHA(ASES)/RAVAL
od120612/2022_2023 : Supply, Installation, Testing and Commissioning of automatic quartozoid type Sprinkler Bulbs of following type, 15 mm BSP thread having a temperature rating of 68 deg centigrade complete with UL certification. Make: KARTAR a. Pendent Type
od120613/2022_2023 : Supply, Installation, Testing and Commissioning of Water/Window Curtain Nozzle, CN, Brass, nickel chrome plated, 1/2" BSPT, K- factor as per catalogue No. HD276, UL Listed. MAKE:ANDEX
od120614/2022_2023 : Supply, Installation, Testing and Commissioning of Deluge Valve -A, 100 NB, Flanged ANSI B16.1, with DI Clapper, Dry Pilot Basic Trim Assembly for DV-A with test & alarm, drain & drip valve, Water Motor Gong Bell UL Listed & FM Approved MAKE:ANDEX
od120615/2022_2023 : Supply, Installation, Testing and Commissioning of Fire Brigade Inlet with 4 nos 100 mm flanged outlet connection and built in gun metal 63 mm Spring loaded check valve for connecting to sump and main header complete with all hardware items. { 4 Way) Make : KARTAR/ AAAG
od120616/2022_2023 : Supply, Installation, Testing and Commissioning of first aid hydraulic Hose Reel meeting EN 671-1 standards, compact type complete with swing type drum, fitted in vertical rising mains/ walls/ structures with U Bolts or with M 12 anchor bolts, including 20 mm dia PVC rigid braided hose in 30M length, fitted with 19mm bore shut off nozzle and all other necessary fixing materials. Make: MONSHER/KARTAR
od120617/2022_2023 : Supply Installation testing and commissioning of Fire Fighting Delivery Hoses, controlled percolating type 35.7 kg/sq cm burst pressure 22 kg/cm proof pressure 14 kg/sq cm working pressure, in 15 Mtrs, as per IS 8423, 63 mm inside coupled with SS Coupling adaptors of instantaneous pattern, pair of male and female parts as per IS 903, 63 mm dia and made functional. Hose & couplings with ISi mark. Make: NEWAGE/OMEX/SWATI/CRC/AAAG
od120618/2022_2023 : Supply & Installation of Hose Cabinets to accommodate two pieces of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made up of MS sheet with glass Fronted hinged doors and lock, painted with scarlet red colour. {Double Door). Make : FRIENDS
od120619/2022_2023 : Supply & Installation of Hose Cabinets to accommodate one piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made up of MS sheet with glass Fronted hinged doors and lock, painted with scarlet red colour. {Single Door). Make : FRIENDS
od120620/2022_2023 : Supply, Installation, Testing & Commissioning of Branch pipe made out of SS Coupling 63 mm short male instant. Inlet male threaded outlet, fitting with 15 mm bore nozzle. Make: AAAG
od120621/2022_2023 : Supply, Installation, Testing and Commissioning of SS Valve 63 mm, confirms to IS: 5290 with, oblique type with instantaneous hose coupling Adaptor complete with blank cap and chain with ISI mark. Make: AAAG
od120622/2022_2023 : Supply, Installation, Testing and Commissioning of Air Release Valve Gun metal body spring loaded type. Make :KARTAR/ ATOM a. 25 mm dia
od120623/2022_2023 : Supplying, Installing, Testing and Commissioning of cast iron Ball Valves with necessary fittings of Screwed end type with ISi mark. Make: ZOLOTO b. 25 mm dia
od120624/2022_2023 : Supplying, Installing, Testing and Commissioning of cast iron Ball Valves with necessary fittings of Screwed end type with ISi mark. Make: ZOLOTO a. 20 mm dia
od120625/2022_2023 : Supply, Installation, Testing and Commissioning of wafer type Butterfly Valves with Black Nitrile rubber integrally moulded onto the body as body seat, Nylon coated SG Iron disc with flow control lever, PN 16 rating, stainless steel disc & stem, conforming to IS 13095 With ISi mark. Make :ZOLOTO c. 150 mm dia
od120626/2022_2023 : Supply, Installation, Testing and Commissioning of wafer type Butterfly Valves with Black Nitrile rubber integrally moulded onto the body as body seat, Nylon coated SG Iron disc with flow control lever, PN 16 rating, stainless steel disc & stem, conforming to IS 13095 With ISi mark. Make :ZOLOTO b. 100 mm dia
od120627/2022_2023 : Supply, Installation, Testing and Commissioning of wafer type Butterfly Valves with Black Nitrile rubber integrally moulded onto the body as body seat, Nylon coated SG Iron disc with flow control lever, PN 16 rating, stainless steel disc & stem, conforming to IS 13095 With ISi mark. Make :ZOLOTO a. 80 mm dia
od120628/2022_2023 : Supply, Installation, Testing & Commissioning of Under Ground MS Heavy Pipes of 'C' Class to confirm IS 1239, including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends, flanges, reducers etc including excavation in foundation trenches or drains including dressing of sides and ramming of bottom, and getting out extra excavated soil and back filling of trenches with available excavated earth, consolidated layer by ramming and watering etc. Pipes shall be coated with two coats of primer and supported at standard intervals and at all tee Joints, bends/ offsets etc. c. 150 mm dia
od120629/2022_2023 : Supply, Installation, Testing & Commissioning of Under Ground MS Heavy Pipes of 'C' Class to confirm IS 1239, including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends, flanges, reducers etc including excavation in foundation trenches or drains including dressing of sides and ramming of bottom, and getting out extra excavated soil and back filling of trenches with available excavated earth, consolidated layer by ramming and watering etc. Pipes shall be coated with two coats of primer and supported at standard intervals and at all tee Joints, bends/ offsets etc. b. 100 mm dia
od120630/2022_2023 : Supply, Installation, Testing & Commissioning of Under Ground MS Heavy Pipes of 'C' Class to confirm IS 1239, including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends, flanges, reducers etc including excavation in foundation trenches or drains including dressing of sides and ramming of bottom, and getting out extra excavated soil and back filling of trenches with available excavated earth, consolidated layer by ramming and watering etc. Pipes shall be coated with two coats of primer and supported at standard intervals and at all tee Joints, bends/ offsets etc. a. 80 mm dia
od120631/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL g. 100 mm dia
od120632/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL f. 80 mm dia
od120633/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL e. 65 mm dia
od120634/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL d. 50 mm dia
od120635/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL c. 40 mm dia
od120636/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL b. 32 mm dia
od120637/2022_2023 : Supply, Installation, Testing & Commissioning of Above Ground MS Heavy Pipes of 'C' Class to confirm IS1239,including cutting, screwing, welding etc Complete with fitting viz. tee, elbow, bends ,flanges, reducers etc.The pipes shall be painted with one coat of primer & two coats of synthetic enamel paint using approved type, MS supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails 'U' & threaded bolt, including cutting, welding, fixing in/on supports/walls, ceiling by using the supports etc, as per standards. Make: JINDAL a. 25mm dia
od120638/2022_2023 : Supply, Installation, testing and commissioning of Industrial type SPOT Pressure Switch weather proof type {RT 116 model) with inlet connection of 1/4 " BSP{F) phosphor bronze bellows, suitable to operate AC/DC supply of 110- 380 /24-250 v respectively with current rating of 6A inductive/10A resistive for Maximum pressure of 230 psi including providing isolation cock. Make : DANFOSS
od120639/2022_2023 : Supply & installation of Pressure Gauge with 0-200 psi range, 3/8' BSP bottom entry 100 MM dial weather proof with SS internals and isolation cock. Make :NATIONAL
od120640/2022_2023 : Supply, Installation, Testing and commissioning of Air Cushion Vessel 200 MM dia having a height of 1.20 M with dished end caps in both sides, air release valve, steel structural stand for floor mounting etc complete and made functional. Air cushion Vessel Make: FABRICATED
od120642/2022_2023 : Supply, Installation, Testing, & Commissioning of 5.5kw/7 10HP 3 phase 2 stage centrifugal monobloc pump, suction 65mmXdelivery50mm, suitable for 180 LPM at 72 M Head. Make: Kirloskar for Jockey Pump (Hydrant & Sprinkler)
od120643/2022_2023 : Supplying, Installation, Testing and Commissioning of End Section centrifugal Pump Cl casing, Cl impeller, C 40 shaft, coupled to make 50 HP, 2920 RPM Diesel engine on a common base frame with coupling and coupling guard suitable for 2850 LPM @ 62 mtr head. Diesel Tank, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc as required. Suitable size exhaust pipe with necessary fittings including insulated with 50 mm thick glass wool with 1.0 mm thick aluminum sheet cladding.MS fabricated common base plate, coupling, coupling guard, foundation bolts etc as required.<br>Make: Kirloskar For Standby Pump( Diesel pump)
od126038/2022_2023 : Supply, Installation, Testing and commissioning of fire fighting pump of horizontal centrifugal end suction type o2850 LPM 62 M head, mechanical seals, Stainless Steel shaft high efficiency volute type with cast iron casing, Cl impeller, pump connected with flexible couplings to a squirrel cage induction motor Totally Enclosed Fan Cooled{TEFC} type of 50 HP, with a supply condition of 415v, 3 phase, 50 HZ, foot mounted type, 2900 RPM<br>including installation of all accessories as per the functional requirements of OEM. Make: Kirloskar Electric Pump For (Hydrant & Sprinkler)
od131363/2022_2023 : Challan Charges for fire for obtaining NOC for the building
od131364/2022_2023 : Charges for preparation of drawing, obtaining approval, Preparing completion report, arranging inspection and obtaining sanction order from Fire Department
4.9 : Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
75.5.1.1pb : Prime Coat - Low porosity - With Packed Bitumen Rates <br> Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
75.5.5.B.2pb : Modified Penetration Macadam 75 mm thick using Bitumen S-65 - Packed Bitumen Rates <br> Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.,including supplying and stacking of materials.
75.5.2.3pb : Tack Coat - With Packed Bitumen Rates <br> Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
75.5.9.1.2pb : 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 - Packed Bitumen Rates<br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65),including supplying and stacking of materials.
75.5.12.A.3.2pb : Seal Coat - Manual Means - Type C - Bitumen S-65 - Packed Bitumen Rates <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means <br> Case III : Type C <br> (II) Bitumen (S-65),including supplying and stacking of materials.
Lee Builders
PERFECT ENGINEERS AND CONTRACTORS
Bidder Name
Lee Builders
PERFECT ENGINEERS AND CONTRACTORS
P A HAMSA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .