| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Not complied prequalification criteria |
| 5 | Rejected-Technical | Rejected-Technical Not complied prequalification criteria |
Tender Value
₹16.1 L
EMD Value
₹32,216
Closing Date
11 Feb 2025, 3:00 pmClosed
SE, VPA
AOB 2ND FLOOR SE CHAMBER
Providing Berth lighting at OR-II Newly developed Berth and repair and reconditioning of 30 Mtr high mast lighting tower. 2nd call
2025_VPT_224558_1
114/24-25/IMEE/ELE/EMP/1326 Dt.22.01.2025
Open Tender
Electrical Works
Works
90 days
VPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹472
Yes
₹32,216
Yes
25 Feb 2025
22 Jan 2025
12 Feb 2025
22 Jan 2025
11 Feb 2025
22 Jan 2025
Amount
Supply, fixing, connecting and commissioning of 200-220 Watts LED flame proof Flood light fitting suitable for gas group of IIA &IIB and zone 1&2 with die cast aluminium housing with heat resistant toughened glass/dome glass/external reflector with all accessories and two cable entries and IP65 protection to existing pole and duly termination with existing flame proof water tight gland-1No for 4C x 2.5 Sq.mm copper FRLS armoured cables as directed by Engineer-in-charge including all labour, tools material and tackles Make : Baliga / FCG / Sudhir / CEAG / Bajaj / CG / FPL
Supply fixing and commissioning of flame proof junction box approx. size 200 x 200 x 167mm aluminium alloy LM6 02 incoming & 04 outgoing glands of suitable sizes cable entry with to the existing pole/frame with GI clamps as directed by Engineer-in-charge including all labour, tools and tackles. Make : Baliga / FCG / Sudhir / CEAG / Bajaj / CG / FPL
Supply & Providing of flame proof double compression cable glands suitable for 4 C X 2.5 to 6 Sq.mm round armoured copper cable as directed by Engineer-in-charge including all labour, tools and tackles. Make: Dowels /Jainson/Comet
Supply & Providing of flame proof double compression cable glands suitable for 4 C X 10 Sq.mm round armoured copper cable as directed by Engineer-in-charge including all labour, tools and tackles. Make: Dowels /Jainson/Comet
Supply & Providing of flame proof double compression cable glands suitable for 4 C X 25 Sq.mm round armoured aluminium cable as directed by Engineer-in-charge including all labour, tools and tackles. Make: Dowels /Jainson/Comet
Supply clamping / drawing and connecting 4C x 2.5 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed PVC overall sheathed, round armoured, multi stranded, copper conductor FRLS cable of approved brand conforming to IS 7098/I, to the pole with existing GI clamps / through GI pipe / to the pole with exiting clamps complete as directed by Engineer-in-charge including all labour, tools and tackles. Makes: Torent / Universal / Unicab / Havells / Gloster/ Polycab
Supply clamping / drawing and connecting 4C x 10 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed, PVC overall sheathed, round armoured, multi stranded copper conductor FRLS cable of approved brand conforming to IS 7098/I, in the existing trench including excavation earth up to 1.0 depth with sand cushioning protective covering and refilling the trench complete as directed by Engineer-in-charge including all labour, tools and tackles. Makes: Torent / Universal / Unicab / Havells / Gloster/ Polycab
Supply clamping / drawing and connecting 4C x 25 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed, PVC overall sheathed, round armoured, multi stranded Alluminium conductor FRLS cable of approved brand conforming to IS 7098/I, in the existing trench including excavation earth up to 1.0 mtr depth with sand cushioning protective covering and refilling the trench complete as directed by Engineer-in-charge including all labour, tools and tackles. Makes: Torent / Universal / Unicab / Havells / Gloster/ Polycab
Supply and fabrication of Galvanised Iron channels/ angles / flats / Nuts & bolts etc., of various sizes / dimensions including cuttings / making bends / drilling holes etc., for making basement back clamps etc., and fixing in position on the pole top / structure for varies uses at site as directed by Engr. I/c complete with all materials, labour, tools & tackles.
Transportation & Erection of 9.5 – 11 Mtr height Rail/PSCC/Spun poles in the existing pit with existing PCC as directed by Engr. I/c complete with all materials, labour, tools & tackles. Note:Spun poles will be supplied by VPA with free of cost.
Excavation of Pit / cable trench in soft / loose soil of required width and depth for erection of poles, laying of poles as directed by Engr. I/c complete with all materials, labour, tools & tackles.
Excavation of pit/trench in Rocky Soil of required width and depth for laying of LT cable/pipe, erection of pole/strut, earth pit/stay set etc. Refilling and making the surface good to match the surroundings including removal of debris complete with all labour, tools, tackles and materials, as directed by Engineer in charge.
Supply & Providing of 1:3:6 PCC with 20 mm graded granite as coarse aggregate and river sand as fine aggregate (220 Kgs of cement per M3of finished concrete) including mixing, depositing in position, tamping, finishing and curing for base concreting, road cutting etc. as directed by engineer in charge including all labour and tools
Supplying, fixing, connecting and commissioning of 25 X 5 MM GI earth strip in recess/surface/clamped to wall/through PCC etc., from earth to switch gear/equipment including connecting the same at both ends as directed by Engineer in charge including all labour and material.
Supply and providing of 2Run x 8 SWG G I Earth wire in horizontal / Vertical run in Ground / surface / Recess including, riveting, soldering, saddles, making connection etc as directed by Engineer in charge including all labour and material.
Supply, laying. clamping / drawing in trench and connecting 3 ½ C x 120 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed PVC overall sheathed round armoured, multi stranded Aluminum conductor FRLS cable of approved brand conforming to IS 7098/I, including excavation of earth at 1 m depth with sand cushioning, protective brick covering at the top and refilling the trench complete as directed by Engineer-in-charge including all labour, tools and tackles. Makes: Torent / Universal / Unicab / Havells / Gloster/ Polycab
Dismantling, Removing of the existing 30 Mtrs High Mast from existing RCC foundation with all accessories and duly removing of Lantern carriage &Head Frame assembly with all accessories on the mast including wire ropes, cables, Luminaries, Control Gear boxes etc., without damage to the materials and providing Crane assistance, including transportation, loading and un-loading labour tools and tackles as directed by engineer-in-charge.
Erection & commissioning of the dismantled 30 m High Mast Tower on existing RCC foundation with all accessories and duly assembling, fixing and commissioning of Lantern carriage & Head Frame assembly with all accessories on the mast including wire ropes, cables, luminaries, control gear boxes etc., and providing crane assistance, including transportation loading and un-loading labour tools and tackles, as directed by engineer-in-charge.
Supply and laying of set of winch drum rope of size 8 mm cont.7/19 stainless steel wire rope as per AISI 316 /304 grade duly providing suitable tumbles and ferrules suitable to Lighting high mast tower as directed by Engg.I/c including transportation loading and unloading etc.
Supply and laying of set of lantern carriage rope of size 6 mm cont.7/19 stainless steel wire rope as per AISI 316 /304 grade duly providing suitable tumbles and ferrules suitable to Lighting high mast tower as directed by Engg.I/c including transportation loading and unloading etc.
Supply and laying of 1100 volts grade 5 core x 4 sq.mm flexible annealed Tinned copper conductor cable with EPR insulated, PCP outer sheathed round trailing cable suitable for High Mast lighting tower application confg. To IS 9968 / Pt-I /88 with latest amndt. Make: Any reputed Brand.
Overhauling and Assembling of High Mast Double drum winch duly de-coupling the motor & winch, servicing, greasing, replacing the winch gear box lubricant including replacing the worn out bearings corroded fasteners for both motor & winch as directed by engineer in charge including transportation, loading and unloading with all labour, tools and tackles.
Supply and Painting of the High mast Tower with one coat of Zinc chromate primer and two coat of silver finish paint on duly cleaned surface with spray painting as directed by Engineer in charge including all labour and material. Make: Asian paint / Nerolac/ Indigo /Berger
M/s D ARJUNA RAO (BID ID -817055)
MEPF INFRA (BID ID -817023)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .