| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC VILL RAVI GRAM PO JOSHIMATH DISTT CHAMOLI UK | JOSHIMATH | CHAMOLI | UK | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹36.1 L+₹1.5 L (4.37%)Rejected-AOC | L2 | Rejected-AOC BEING L2 | |
| 3 | L3₹36.3 L+₹1.7 L (4.96%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | L3 | Rejected-AOC BEING L3 | |
| 4 | L4₹38.5 L+₹3.9 L (11.4%)Rejected-AOC | L4 | Rejected-AOC BEING L4 | |
| 5 | L5₹39.1 L+₹4.5 L (13.0%)Rejected-AOC | L5 | Rejected-AOC BEING L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE 871 EWS
GE 871 EWS C/O 56 APO
PROVN OF ONE STORAGE SHELTER 9(I) MTN BDE AND FOUR LT VEHICLES REPAIRS SHED AND SPECIAL REPAIRS TO BLDG NO T-7B OF GARHWAL SCOUT AT JOSHIMATH UDNER GE 871 EWS
2020_MES_401673_2
8556/E8
Open Tender
Civil Works
Works
180 days
JOSHIMATH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹70,000
Yes
12 Feb 2021
2 Jan 2021
27 Jan 2021
4 Jan 2021
25 Jan 2021
11 Jan 2021
4 Jan 2021 - 18 Jan 2021
Amount
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in hard dense soil all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in hard rock by chiselling or by mechanical means all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soil all as specified and directed.
Removing excavated material soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for providing cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete all as specified and directed.
M&L cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L RCC M-25 grade (Design Mix), using 20 mm graded crushed stone aggregate as in footing and plinth beams all as specified and directed.
M&L RCC M-25 grade (Design Mix), using 20 mm graded crushed stone aggregate, as in columns all as specified and directed.
M&L RCC M-25 grade (Design Mix), using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span all as specified and directed.
M&L RCC M-25 grade (Design Mix), using 20 mm graded crushed stone aggregate, as in slab supported on walls, beams ansd column in floors, roofs, landings, balconies, deck slabs and in shelves all as specified and directed.
M&L RCC M-25 grade (Design Mix), using 20 mm graded crushed stone aggregate, as in chajjas all as specified and directed.
M&L 40mm thick DPC cement concrete 1 :2:4 type B-0 (using 12.5mm graded stone aggregates) horizontal or vertical surfaces including necessary formwork all as specified and directed.
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.
M&L mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.
M&L mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.
Use and waste form work to sides of concrete in foundation, footing, bases of columns and plinth beam all as specified and directed.
Use and waste form work to sides of pillars, posts, struts, piers, column and stanchions all as specified and directed.
Use and waste form work to side and soffits of floor beams. lintel beam, roof beam , landing, waist slabs, chajja railing and similar work all as specified and directed.
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) all as specified and directed.
Use and waste form work to chajjas, chullah hoods, troughs and similar work etc. all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, break in floors, window cills, concrete walls, floor and roofs not exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide all as specified and directed.
S&F rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe – 410 W Gde E-250 including cutting, welding all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe – 410 W Gde E-250 all as specified and directed.
S&F framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde -E-165 all as specified and directed.
S&F plates (plain or chequered) channels. square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified and directed.
S&F mild steel bolt hexagonal or square head at one end and screwed the other or screwed both ends to fe fitted with washer and one hexagonal or square nut exc 30cm long exc 12 n exc 20 mm dia of neck all as specified and directed.
S&F 16 to 20 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long all as specified and directed.
S&F 11 to 15 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long all as specified and directed.
M&L pre cast cement concrete solid block masonary in PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) exceeding 10cm thick and set in cement mortar 1:6 all as specified and directed.
M&L precast cement concrete solid block masonry in PCC 1:3:6 (using 20 mm graded crushed stone aggregate, 10 cm thick wall and set in CM (1:4) all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:6 finished surfaces even and smooth without using extra cement all as specified and directed.
M&L rendering 15mm thick in cement mortar 1:4 finished surfaces even and smooth without using extra cement by using WPC as per manufacturer instructions all as specified and directed.
M&L rendering 5 mm thick in cement mortar 1:3 on ceiling, surfaces finished even and smooth without using extra cement all as specified and directed.
M&L preparation of new plastered surface of wall and applying three coats of white wash all as specified and directed.
M&L preparation of new plastered surfaces of ceiling and applying three coat of white wash all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of 2 mm thick wall care putty all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coat of cement base paint over a coat of primer all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw all as specified and directed.
S&F 2nd class hard wood in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed.
S&F pressed steel frames for doors with one or more rebates (size of frame 125x60mm) including necessary fixing lugs, hinges, lock strike plate as specified and directed.
S&F flush shutters 30 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F 35mm thick IInd class hard wood glazed and skelton door shutter divided into square, open rebated and prepared to receive glass/gauge etc (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.20 (a) all as specified and directed.
S&F solid PVC door frame of size 50 mmx47mm made out of 5 mm plain colour PVC sheet re-inforced with M.S square tube and S&F in opening as per specification and drg complete all as specified and directed..
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip 20 mm width struck inside with solvent cement for stiles and plain colour of PVC sheet for top rail lock rail and bottom rail, on either side & gap insert for top rail bottom rail panelling of plain colour PVC sheets to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppying and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F anodised aluminum section for making doors, windows, partition wall, shutters etc including styles & rails with standard anodized aluminum section, with one or more rebates including aluminium snap beading complete all as specified and directed Note Glazing, rubber beading, hinges etc shall be measured and paid separately)
M&L rubber beading for fixing glass panes in aluminium frame work all as specified and directed.
S&F steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed.
M&L 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each panes all as specified and directed.
S&F for 4 mm thick sheet glass, fixed to aluminum frame work in panels n.exc 0.5 Sqm in each pane, complete all as specified and directed.
S&F 0.56 mm nominal dia wire galvanised mild steel wire cloth and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple all as specifed and directed.
S&F butt hinges of stainless steel 100mm size all as specifed and directed.
S&F 100 mm long medium weight cold rolled mild steel butt hinges all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple 250 mm long (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed.
S&F extruded Aluminium alloy handles 150 mm long, fabricated type anodised all as specified and directed.
S&F aluminium anodised, barrel tower bolts150mm long of extruded section and fixed all as specified and directed.
S&F in repairs floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size) all as specified and directed.
S&F in repair for 20 mm dia chromium plated pipes for curtain rods all as specified and directed.
S&F in repair for chromium plated brackets and knobs for curtain rods all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed..
M&L preparation of new wooden surfaces of any description over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed..
M&L everest designer false suspended false ceiling using GI exposed ceiling suspension system of grid size 600mmx600mm with main runner 38mmx24mm, cross tee 29mmx24mm & wall angle 24mmx24mm including 6 mm thick (High pressure steam cured), pre-painted self embossed, reinforced designer cement board, conforming to IS 14862:2000, to be placed in a grid of G.I. system duly suspended with 4mm dia G.I./M.S. bar hanger fixed with steel dash fastner or iron purlins from the roof with adjustment clip providing position for light fixture etc all as specified and directed.
M&L washing, rubbing with water and providing 20mm thick cement plaster in cement mortor 1:4 finish fair and even without using extra cement to receive water proofing treatment and providing and laying of water proofing treatment on roof with APP modified prefabricated five layer 3mm thick water proofing membrane super thermo lay of STP ltd or DR Fixit (TORCH SHIELD) with non woven polyster mat reinforement of 160 gsm weight of membrane @ 3.6 Kg/sqm over a solvent based bitumen primer shalitex primer or equivalent @ 0.3Ltr/sqm by same manufacturer confirming to IS : 3384-1986 .The membrane shall be laid using butane torch .The end lap should be 100mm and the side lap must be minimum 75mm all as specified and directed.
M&L spreading and levelling in layers, well ramming including watering not exc. 25 cm thick all as specified and directed.
M&L hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified and directed.
M&L providing 100mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base in floor/paving all as specified and directed.
M&L 25 mm thick 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) finished surfaces even and smooth without using extra cement as in levelling course all as specified and directed.
M&L providing 100mm thick cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in floor/paving finishing top surfaces even and smooth without using extra cement all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), finishing top surfaces even and fair without using extra cement as in plinth protection all as specified and directed.
M&L prepolished chequered cement concrete tiles with white cement and pigments of size 25cmx25cmx25 mm thick or 30cmx30cmx25mm thick set and jointed in neat cement slurry and pointed in white/ coloured cement laid over and including 20mm thick screed bed or bedding layers in CM 1:6 to match the surfaces all as specified and directed.
M&L forming contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound grade 'A' all as specified and directed.
M&L forming construction joints 30mm deep x 10mm wide filled with sealing compound grade 'A' all as specified and directed.
Dismantling plain corrugated steel sheeting any gauge thickness including Nainital and similar pattern all as specified and directed.
Dismantling of wall and ceiling board any thickness including cover fillets all as specified and directed.
Dismantling frame work of timber in scantling 40 Sq cm and over in section in any position all as specified and directed.
Dismantling of frame work of timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section all as specified and directed.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) area exc. 1.5 sqm but n exc. 4 sqm each all as specified and directed.
Taking down door/window shutter/cupboard shutter with frame (without taking off shutters from the frame) area nexc 1.5 sqm each all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thick (below or above ground level) all as specifed and directed.
Demolition of concrete unreinforced of any description and in any position not otherwise specifically provided for all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar all as specified and directed.
Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store all as specifed and directed.
Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store all as specifed and directed.
Dismantling water tank and removing to store capacity exc 250 but not exc 500 ltrs all as specifed and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channel and drain all as specified and directed.
Extra for forming fair finished drain and channel 30 cm inner grith in cement concrete using extra cement in forms mould mitred/stopped ends all as specified and directed.
M&L Non Skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles and laid over a screed bed of 15 mm thick in CM 1:6 all as specified and directed.
M&L Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 but not exceeding 0.38 sqm, in skirting/vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles and laid over and including 10 mm thick rendering as in backing coat in CM 1:4 all as specified and directed.
M&L Non skid ceramic coloured tiles (300x300)x7 mm thick in floors etc. set and jointed in neat cemenbt slurry and pointed in white or coloured cement to match and laid over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 all as specifed and directed.
M&L glazed ceramic coloured tiles of size (300x200) x7mm thick laid over and ncluding 10 mm thick rendering in CM 1:4 as in backing coat for tiles on vertical surfaces,set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specifed and directed.
M&L 16-18mm thick granite slab on top of cooking platform and bar counter including cutting polishing rounding on edge etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15mm thick screed bed in CM 1:4. including grinding and polishing all as specified and as directed.
S&F 15mm bore GI tubing medium grade with all fittings and fixtures fixed to wall and ceiling or laid in floor all as specifed and directed.
S&F 20mm bore GI tubing medium grade with all fittings and fixtures fixed to wall and ceiling or laid in floor all as specifed and as directed.
S&F in repair vitreous china squatting pan 'Orissa' pattern of size 580x440mm with white integral footrest (excluding flushing cistern and flush pipe including making good the disturbed surfaces) all as specifed and directed.
S&F in repair vitreous china wash hand basin (550X400mm) white, flat back excluding taps, waste chain and plug and porcelain stopper but including brackets all as specifed and as directed.
S&F in repair 32mm bore waste fittings brass chromium plated for glazed ware sinks basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed all as specifed and directed.
S&F in repair 10 ltrs capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float , flush pipe and handle including brackets all as specifed and directed.
S&F in repair PVC connection 15mm dia and 600mm long all as specifed and directed.
S&F in repair PVC waste pipe 32mm dia complete all as specifed and directed.
S&F in repair 15 mm dia bib tap CP fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrules all as specifed and directed.
S&F in repair 15mm bore chromium plated brass angle cock screwed for iron pipe or union all as specifed and directed.
S&F in repair 15mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall all as specifed and directed.
S&F rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule all as specifed and directed.
S&F in repair CP towel rail with hook 600mm long all as specifed and directed.
S&F in repairs 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floor all as specifed and directed.
S&F in repairs 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floor all as specifed and directed.
M&L 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed.
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc. removing materials from site and keeping in safe custudy for taking as sch of credit(credit for above items should be made as per conditions separately) and depositing to MES store yard and making good to the disturbed surface of walls, floors roof etc all as specified and directed.
Dismantling and taking down of unserviceable old existing submain wire/ service cable of any size all as specified and directed.
Dismantling and taking down of unserviceable distribution boards all as specified and directed.
M&L for point wiring (concealed in wall) complete using approved colour coding as per IS (Red, Black, Green for single phase circuit) with multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area, single core PVC insulated unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC medium grade conduit with accessories such as bend, tee, junction boxes, elbows etc, ISI marked with valid CML No. (IS :9537 -1983 for conduit and IS :9537 -1976 for conduit accessories) including pressed steel terminal sunken boxes 1.6 mm thickness, 65mm deep with earth dolly, duly painted with two coats of black bitumenous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws, cup washers and PVC unsheathed copper conductor 1.5 Sqmm cross sectional area, single core FRLS cable as earth continuity wire connetctd to DBs/sunken boxes/fittings conductor and all other metal parts with earth dolly all as specified and directed for One Light/fan point controlled by one switch 5/6 Amp
All as per item No 113 herein before but one 5/6 Amp socket point controlled by one switch on the same board.
All as per item No 113 herein before but One 5/6 Amp socket point controlled by one switch independent board.
All as per item No 113 here in before but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F sub main wiring in PVC casing and caping of required size 2 x 4.0 Sqmm PVC insulated multistranded copper conductor with 01x2.5 Sqmm PVC insulated multistranded copper conductor as earth continuity wire all as specified and directed.Make : Havells/Anchor/Polycab/Mescab
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed. Make : Havells/Anchor/legrand/HPL
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed. Make : Havells/Anchor/legrand/HPL
S&F socket out let 5 pin 5/6 Amps all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F ceiling rose 2/3 terminals 65x25 mm dia polycarbonate isolated all as specified and directed. Make :Havells/SSK/Cona
S&F of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F of 9 watt LED bulb cool day light, 230/240V AC supply all as specified and directed. Make : Havells/philips/Bajaj
S&F LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fittting connector all as specified and directed. Make : Havells LHEXBLP7PN1W018 or equivalent Philips/Baja/CG
S&F of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution with fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with three core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- Make:- Havells Cat Part No: ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent CG/ Bajaj/HPL
Supply and fix of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed. Make:-Legrand/Schneider/ Havells /HPL
Supply and fix MCB 6-40 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
S&F MCB single pole with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistance moulding suitable for single phase circuit of 6 to 32 Amps.Make : Havells/Anchor/legrand/HPL
Supply and fix in replcement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
S&F exhaust fan MS body AC single phase 230/240, 50 HZ volt of size 300 mm sweep power flow operating with louvers shutter grouting the ragged bolt in wall fixing the frame and exhaust fan fix including louver shutter with frame on the exhaust side and connecting with PVC insulator 3 core 23/0.0076 copper wire rubber insulated from ceiling rose to exhaust fan motor all as specified and as directed. Make: Havells, bajaj, CG, Anchor
S&F electric storage water heater of capacity 50 Ltrs of five star rating, AC 230 volts with PVC connection pipe 15 mm dia heavy duty approx length 450/600mm long -02 Nos, Hole fastener, Nut & Bolts made of iron approx length 6 cm long -04 Nos, union socket 15mm dia -02 Nos, Tee 15 mm dia -01 Nos, GI pipe 15 mm dia -6 RM ,stop valve -02 Nos stainlness steel all as specified and directed Make - Havells cat part No. GHWASESWH025 (Model No. Senzo) or equivalent Crompton/V-Gaurd
S&F surface and wall mounted LED tube light fitting with polycarbonate housing & integrated electronic driver with tube rod of 18 watt slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make: Havells, CG, Philips, Bajaj.
M&L earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick buried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 all as specified and directed and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate for earthing cover reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm, funnel with GI watering pipe 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
M&L for earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI thimbles, bolt nuts, check nuts and washers of including providing earth wire protection GI pipe medium grade 40mm bore from earth plate to main switch board/panel, watering pipe 20mm bore with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using 8 @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and common salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and directed including testing on completion, for machinery/ equipment installed at power house/sub station all as specified and directed.
S&F single pointed air termination aluminium rod 12mm dia, 300 mm long all as specified and directed.
S&F test point terminal block of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexogonal head screws all as specified and directed.
Supply and fix of aluminium strip 25 x 3.15mm with saddles and fixing screws, haevy duty porcelain insulators rawl plugs etc for conductor for roof and fixed on wall upto test point all as specified and directed.
S&F wooden block heavy weight of size 25x25x25 cm with hole of 20 cm for fixing of air termination rod of any size all as specified and directed.
Supply and laying GI tubes light grade, galvanised, 20mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable length equal to width of bricks all as specified and directed.
Supply and laying in trenches or fixed to wall/pole UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with multi stranded aluminium conductor, 1100 volt grade of size 10 Sqmm 4 core all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 4 core including all fixtures and fittings all as specified and directed. Make:-Havells/Polycab/Finolex/Universal
Supply and lay in trenches, fixed to wall/pole UG cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured heavy duty electric cable with multi stranded Aluminium conductor , 1100V grade of size 10 sqmm 4 core all as specified and directed. Make : Havells/Universal cable/Mescab/Polycab
M&L 25 mm dia steel tubes (light grade) galvanised with all fittings and fixtures, laid in trenches/wall/pole for protection of underground cable when crossing the road/fixing all as specified and directed.
M&L 32 mm dia steel tubes (light grade) galvanised with all fittings and fixtures, laid in trenches/wall/pole for protection of underground cable when crossing the road/fixing all as specified and directed.
Supply and fix of light grade Galvanised mild steel pipe 40mm bore with all fittings and fixtures laid under road crossing, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers as for cable protection all as specified and directed .Make :- Jindal/TATA/Prakash surya
Supply,install, testing and commissioning MCCBs in existing LT panel box/feeder pillar boxes (KIOSK) of capacity 25 to 100 Amps 4 pole breaking capacity 16 KA with thermal as well as magnetic balance adjustable type all as specified and directed.
SIDHARTH CONSTRUCTION
M/S Swarn Constructions
VAIBHAV ENTERPRISES
Harendra Singh Panwar
M/S RAJESH ARORA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .