Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L1 | Accepted-AOC lowest | |
| 2 | L2₹17.9 L+₹2.5 L (16.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹18.3 L+₹2.9 L (18.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹20.9 L+₹5.5 L (35.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹21.3 L+₹5.9 L (38.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹27.3 L
EMD Value
₹54,500
Closing Date
24 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
PROVN OF CERTAIN SANCTIONED WORKS UNDER AGE EM OF AOR GE SAMBA
2021_MES_461554_1
GE/SMB/T-29/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹54,500
Yes
16 Nov 2021
27 Aug 2021
25 Sept 2021
27 Aug 2021
24 Sept 2021
11 Sept 2021
27 Aug 2021 - 31 Aug 2021
60 days
Amount
Taking down old unserviceable aluminium point wiring (light, fan, socket , power socket and bulk head fittings) from PVC/metallic conduit,on surface wiring, on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc complete all as specfied and directed.
Point wiring for light / fan controlled by one switch with 1.5 sq mm single core PVC insulated unsheathed multistranded copper conductor FRLS with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodised pressed steel sunken box having thickness not less than 2mm with 3mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping including insulation test of point wiring and making good disturbed surfaces area and white wash/colour wash to matching with the existing colour and point wiring connection will be tapped from nearest point and complete all as specified and directed. Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per srl item No 2 above but for 3 pin 5 amps independent board complete all as specified and directed.
All as per srl item No 2 above but for 3 pin 5 amps same board complete all as specified and directed.
All as per srl item No 2 above but for One light point controlled by two way switch complete all as specified and directed.
Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC casing & caping with all fittings including anodised pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour complete all as specified and directed.Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Switch piano flush type single pole, 10 Amp, two way, AC 230 volts etc complete, all as specified and directed.
Switch piano flush type one way 5 amps SP complete all as specified and directed
Switch piano flush type single pole, 15 Amp, one way, AC 230 volts etc complete, all as specified and directed.
Socket outlet 3 pin 5 amps flush type complete all as specified and directed.
Socket outlet multipurpose 2 in 1, 6 pin 6 and 16 amps controlled by one switch flush type universal .
Bell push flush type with indicator 6 Amps complete all as specified and directed.
Electronic bell ding-dong AC 230 Volts single pole complete all as specified and diercted.
Ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Ceiling fan regulator electronic type 5 stage speed variation,socket type is size, ISI marked complete all as specified and directed.
Lamp holder/batton holder/angle holder insulated body(Metal ring) with back bakelite plate suitable for batten fittings.
LED tube light fitting 20 watt, 230 volt,box type complete bipin holders, connector,mounted on PVC block and retro LED rod of 20 watt with aluminium heat sink & polycarbonate diffuser having high efficacy (single side connection) complete with all accessories internally pre wired batten(single side connection) and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed,LED tube rod ,make :Havells ,cat part no:REGALBATTENT5UPTO1X22WSSBSWH and LED tube light batten ,make :Havells , Cat Part No :PHOTONULTRAE2.01213T8SSTL20WLED865SPC or technocommerically equivalant make of Crompton/Philips Note: (i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboraory. (ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 5 years form the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost. (iv) Contractor shall arrange 70 % material at site for approval of GE before incorporation in the work.
Sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO (for incoming ) (b) MCB SP 06- 40 amps = 4 Nos (for outgoings) . ( Note :- (i)The DB shall be VTPN series of Make : Schneider ,Cat Part no: A9HVD04L or equivalent make of L&T/ ABB . (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost .
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 08 ways complete all as specified and directed.
MCB SPN 6-32 amps 240 Volt 'C' series complete all as specified and as directed.
MCB SP 6 to 32 amps 240 Volt 'B' series complete all as specified and as directed.
Taking down the unservicable /brunt sub main wiring from wooden batten and provisioning of submain wiring in and including PVC conduit 1.8 mm thick ,20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 4 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 4 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is included in the quoted rate. 2. Soil should be free from stone, boulders, aggregate, gravels etc.
Providing/cutting the round /square hole of required size in wall finishing the same for disturbed surfaces complete all as specified and supply and fixing propeller type AC ventilating fans, Single phase , 230 volts 300 mm sweep metallic complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall ) and connecting with and including PVC insulated three core 1.5 SQMM copper cable from ceiling rose to exhaust fan with black synthetic enemel paint 2.0 cm high complete all as specified.Make of Exhaust fan - Havells, Model Turbo Power(1Ph) or technocommerically equivalent Crompton/Philips/Bajaj.
GI water tubing medium grade of bore 15 mm dia with all fitting like as (Elbow, Tee, Sockets, Union, Nipple, and bend etc) on wall complete all as specified and directed by Engr-in-Charge.
Bib taps, 15 mm dia cast copper alloy with crutch or butterfly nuts screwed for iron pipe and fixed in 20mm bore dia pipe complete all as specified and directed by Engr-in-Charge.
Stop valves of 15 mm bore, cast copper alloy screwed down high pressure, with cruch or butter fly handle, screwed both ends 20 mm GI water tubing complete all as specified and directed by Engr-in-Charge.
Water heater storage type, electric, capacity 25 Ltrs, BEE 5star rated pressure 8 bar 3 level safety capillary thermostat, automatic thermal cut-out & multifunctional valve to provide higher safety with set of hot and cold flexible connection pipe and connecting electrically complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
All as per srl item No.29 above here-in-before but depth exceeding 1.5 Mtr and not exceeding 3 mtr complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including use of necessary form works for rough finished surface complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping to poles including use of necessary form works for rough finished surface complete all as specified and directed.
Supply & errection steel tubular swaged poles type 410 SP-55 (11 meter long) with 300mmx300mmx6mm MS base plate continuously welded to pole, finial taper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30 cm high with super enamel paint (black and white/yellow) from ground level/coping upto 1.5 m painting with two coats of aluminium paint for the remaining height complete all as specified and as directed. (Note : Excavation & earth work, GI Pipe shall be measured and paid for separately under respective items of BOQ).
Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured complete all as specified and directed.
Galvanised iron round bracket made out of 40mm dia GI tubing including making provision for fixing of 06 no flood light on 11 mtr steel tubular pole, fixing and connecting up of LED lights (LED lights shall be measured and paid for seperately under respective items of BOQ ) complete all as specified and directed.
LED flood light fitting 200 Watts (with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 66 and external SPD of capacity 10 KV in addition to inbuilt SPD of electronic driver , having Pressure die cast housing with high efficient output emitter LED for better distribution, protection with heat resistant toughned glass with individual LED lenses complete including MS Clamps of suitable size for fixing on High Mast /Pole complete all as specified and directed.
XLPE under ground cable Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes 25 sqmm 4 core complete all as specified and directed. Note: Earth work ( Excavation, returning & refilling in and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A' BOQ.
Returning, filling, in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed.
Sand cushioning to under ground electric cable a layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable complete all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be of good quality as specifed and punned thickness shall be measured and paid.
Sub class 'B' bricks of old size (230x115x75 mm) or of size , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply, installation, testing and commissoning street light panel 3 phase ,Astronomical timer contactor rating 65/TP, MCB rating 63/TPN made out of 3mm thick CRCA sheet, double door type with slopy canopy suitable for outdoor installation with angle iron frame made out of 40 x 40 x 6mm at vertical corners & Medium Chanel at base of Panel board floor mounted, dust and vermin proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (Screwed), grouted in PCC 1:2:4 complete all as specified and directed .
Motorised revolving search light suitable for 400 watt having contiuously rotation 180 degree ,5 RPM in horizontal plane of Make : Kalin Cat Part No. RSL-LVS35G40, capsul halogen, effective range 600 to 800 mtrs, operating voltage 230 V , AC or technocommerically equivalent complete all as specified and directed
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Vishav Karma Refrigeration and Electric Work
M/S KRISHAN SONS
Jiwan Singh
vishesh engineers
M G ASSOCIATES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .