Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance LANE NO 03 PRAGATI VIHAR RISHIKESH | ₹9.9 L | L1 | Accepted-Finance L1 |
| 2 | L2₹10.7 LAccepted-Finance | ₹10.7 L | L2 | Accepted-Finance L2 |
| 3 | L3₹10.9 LAccepted-Finance B 43 CIVIL LINES 1ST FLOOR NAYAPURA KOTA RAJASTHAN 324001 UDYAM RJ 24 0019224 08ABKPA3675N1Z9 R M | KOTA | RAJASTHAN | 324001 | ₹10.9 L | L3 | Accepted-Finance L3 |
| Sl No | Description | Qty | Unit | M/s Singhal and Co L3 | KOTHARI ENTERPRISES L1 | Himalayan Power Solution Company L2 |
|---|---|---|---|---|---|---|
| 1.01 | Providing of 33 KV Vaccum Circuit Breaker (110Volt DC) 2000Amp, Porcelain outdoor type with GI support structure as per drawing and required accessories of approved vendor of PTCUL including transportation, loading, unloading etc. | 1 | No | 4,95,000 ₹5.0 L | 6,48,000 ₹6.5 L | 5,90,000 ₹5.9 L |
| 1.02 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means including getting out and disposal of excavated earth | 1.99 | Cum | 350 ₹696.50 | 450 ₹895.50 | 750 ₹1,492.50 |
| 1.03 | Steel Reinforcement for R.C.C work including strenghthning, cutting, bending, placing in position & binding all complete above plinth level with cold twisted bars of size 20mm.. | 110 | Kg | 95 ₹10,450 | 75 ₹8,250 | 95 ₹10,450 |
| 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) for grouting the 8 anchor bolts ( size 4x1x1.5cum) | 2.49 | Cum | 8,500 ₹21,165 | 8,450 ₹21,040.50 | 9,450 ₹23,530.50 |
| 1.05 | Work of opening of jumpers from bus isolator of 33 KV Bus I at 132 KV substation Majra with essential T&P. | 1 | Job | 10,000 ₹10,000 | 950 ₹950 | 1,500 ₹1,500 |
| 1.06 | Shifting of new 33 KV VCB with structure frame,poles, mechanical cubical and accessories from store to working site with proper safety and care including labour and T&P etc. to complete the work. | 1 | Job | 15,000 ₹15,000 | 7,500 ₹7,500 | 18,500 ₹18,500 |
| 1.07 | Work of Providing and fixing of MS Flat of size 50X6mm for earthing of circuit breaker. | 0.3 | MT | 1,18,000 ₹35,400 | 85,000 ₹25,500 | 1,15,000 ₹34,500 |
| 1.08 | Providing laying and connection of 2.5 sqmm copper control cable for remote operation including indications lamps and TNC switch and other related items for new installed breaker from Majra control room | 0.4 | Km | 1,45,000 ₹58,000 | 2,25,000 ₹90,000 | 3,15,000 ₹1.3 L |
| 1.09 | Work of ertection testing (Contact Resistance Measurement, IR Test Opening and closing Time test) and commissioning of 33 KV VCB complete with structure, frame, mechanism cubical, cubical brackets, platform structure and other accessories etc. as per manufacture drawing and manual including cost of material and labour and T&P. | 1 | Job | 15,000 ₹15,000 | 24,500 ₹24,500 | 29,500 ₹29,500 |
| 1.10 | Providing and fixing of 33 KV CB Clamps for newly installed breaker for 33 KV bus section Ist at Majra. | 6 | No | 2,500 ₹15,000 | 1,850 ₹11,100 | 2,650 ₹15,900 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
5 Jan 2026, 6:00 pmClosed
SE O AND M CIRCLE DDUN
SE O AND M CIRCLE DDUN
Providing Commissioning and Testing of 36kV VCB and other Associated Work for 33 KV Bus Section Ist at 132KV substation Majra
2025_PTCUX_89758_1
T 53 SE O and M CR D Dun 2025 26
Open Tender
Electrical Works
120 days
WORK
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE O AND M DIV YAMUNA COLONY PTCUL DEHRADUN
₹30,000
23 May 2026
12 Dec 2025
7 Jan 2026
12 Dec 2025
5 Jan 2026
12 Dec 2025
Providing of 33 KV Vaccum Circuit Breaker (110Volt DC) 2000Amp, Porcelain outdoor type with GI support structure as per drawing and required accessories of approved vendor of PTCUL including transportation, loading, unloading etc.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means including getting out and disposal of excavated earth
Steel Reinforcement for R.C.C work including strenghthning, cutting, bending, placing in position & binding all complete above plinth level with cold twisted bars of size 20mm..
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) for grouting the 8 anchor bolts ( size 4x1x1.5cum)
Work of opening of jumpers from bus isolator of 33 KV Bus I at 132 KV substation Majra with essential T&P.
Shifting of new 33 KV VCB with structure frame,poles, mechanical cubical and accessories from store to working site with proper safety and care including labour and T&P etc. to complete the work.
Work of Providing and fixing of MS Flat of size 50X6mm for earthing of circuit breaker.
Providing laying and connection of 2.5 sqmm copper control cable for remote operation including indications lamps and TNC switch and other related items for new installed breaker from Majra control room
Work of ertection testing (Contact Resistance Measurement, IR Test Opening and closing Time test) and commissioning of 33 KV VCB complete with structure, frame, mechanism cubical, cubical brackets, platform structure and other accessories etc. as per manufacture drawing and manual including cost of material and labour and T&P.
Providing and fixing of 33 KV CB Clamps for newly installed breaker for 33 KV bus section Ist at Majra.
Providing and fixing of c-wej clamps of Moose to moose conductor
Providing and fixing of isolator pad clamps
Work of Jumpering, of 33 KV Breaker from 33 KV Bus I to connect newly installed 33 KV VCB including cost of labour and T&P.
Supervision charges for representative of OEM
Work of complete overhauling of 15 KVA DG Set of Sonalika make and replacement of damage diesel hose pipe of DG Set at 132 KV Majra.
Work of replacement of jaw and blades of 33 KV Bus section isolator of Jack Bus Ist and Iind isolator of Majra, including opening of jumpers and dropers.
Work of complete overhauling of 33 KV CB of Niranjanpur, Araghar Ist and Dun university feeder at Majra work includes contact resistance test, and circuit breaker tripping and closing timing test etc.
Work of finding and rectifying the fault in FCBC of 500 AH Battery charger Iind of sinetech make battery charger of Majra works includes replacement of faulty parts like overload relay, phase sequence relay and any other part of battery charger and also complete overhauling of battery charger sine tech make.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.89 MB
TENDERDOCT53.pdf
Tender Documents • 0.57 MB
BOQ_106408.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid