Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹87.7 L+₹11.6 L (15.3%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT RECOMMENDED FOR OPENING OF BID AS YOUR FIRM NOT ENLISTED IN REQUISITE CATEGORY i.e. b (i) |
| Sl No | Description | Qty | Unit | Maruti Abhiyantriki L2 | BHAVIN INFRA L1 |
|---|---|---|---|---|---|
| 1.00 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge | 409.9 | Cum | 150 ₹61,485 Lowest | 150 ₹61,485 Lowest |
| 2.00 | All as per item No 1 (here-in-before) but depth exc 1.50 m and not exc 3.00 m etc complete all as specified and directed by Engineer-in-Charge | 16.9 | Cum | 160 ₹2,704 Lowest | 160 ₹2,704 Lowest |
| 3.00 | Excavation in treanches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells exc 10 sqm on plan and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge | 765.39 | Cum | 180 ₹1,37,770.2 Lowest | 180 ₹1,37,770.2 Lowest |
| 4.00 | All as per item No 3 (here-in-before) but in Hard/Dense Soil | 1 | Cum | 200 ₹200 Lowest | 200 ₹200 Lowest |
| 5.00 | M&L Cement concrete 1:4:8 type D-2 (using 40mm graded stone aggrwgate) in foundations, filling and mass concrete complete all as specified and directed . | 114.84 | Cum | 4,200 ₹4,82,328 Lowest | 4,200 ₹4,82,328 Lowest |
| 6.00 | M&L Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggrwgate) in foundations, filling and mass concrete complete all as specified and directed . | 81.82 | Cum | 4,100 ₹3,35,462 Lowest | 4,100 ₹3,35,462 Lowest |
| 7.00 | M&L 100 mm thick PCC1:2:4 type B- 2, using 40 mm graded stone aggregate, finishing concrete surfaes even and smooth without using extra cement including spike rolling to to surface whilst concrete is green complete all as specified and directed. | 800 | Sqm | 750 ₹6,00,000 | 350 ₹2,80,000 Lowest |
| 8.00 | M&L Reinforced cement concrete M-25 grade (design mix) using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement
slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge | 2 | Cum | 7,600 ₹15,200 Lowest | 7,600 ₹15,200 Lowest |
| 9.00 | M&L Reinforced cement concrete M-25 grade (design mix) using 20 mm graded aggregate in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses etc complete all as specified and directed by Engineer-in-Charge | 5.3 | Cum | 8,000 ₹42,400 Lowest | 8,000 ₹42,400 Lowest |
| 10.00 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete flat etc complete all as specified and directed by Engg-in-charge. | 10 | Sqm | 300 ₹3,000 Lowest | 300 ₹3,000 Lowest |
Tender Value
₹87.7 L
EMD Value
₹1.6 L
Closing Date
9 Jun 2025, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH) - 422401
AS PER TENDER DOCUMENTS
2025_MES_706755_1
88634/E8
Open Tender
Civil Works
Item Rate
180 days
AHILYANAGAR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE NORTH AHILYANAGAR
₹1.6 L
Yes
13 Aug 2025
5 May 2025
16 Jun 2025
5 May 2025
9 Jun 2025
26 May 2025
6 May 2025 - 13 May 2025
Amount
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge
All as per item No 1 (here-in-before) but depth exc 1.50 m and not exc 3.00 m etc complete all as specified and directed by Engineer-in-Charge
Excavation in treanches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells exc 10 sqm on plan and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
All as per item No 3 (here-in-before) but in Hard/Dense Soil
M&L Cement concrete 1:4:8 type D-2 (using 40mm graded stone aggrwgate) in foundations, filling and mass concrete complete all as specified and directed .
M&L Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggrwgate) in foundations, filling and mass concrete complete all as specified and directed .
M&L 100 mm thick PCC1:2:4 type B- 2, using 40 mm graded stone aggregate, finishing concrete surfaes even and smooth without using extra cement including spike rolling to to surface whilst concrete is green complete all as specified and directed.
M&L Reinforced cement concrete M-25 grade (design mix) using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge
M&L Reinforced cement concrete M-25 grade (design mix) using 20 mm graded aggregate in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses etc complete all as specified and directed by Engineer-in-Charge
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete flat etc complete all as specified and directed by Engg-in-charge.
Use and waste Formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter rough finished surfaces of concrete flat etc complete all as specified and directed by Engg-in-charge.
M&L MS TMT bars (Fe 500D)10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including annealed MS wire not less than 0.90 mm dia as required and as directed by Engineer-in charge.
M&L for rendering, 15 mm thick on fair faces of brickwork / concrete surfaces in cement mortar 1:3 surfaces finished even and smooth without using extra cement
M&L for rendering, 15 mm thick on fair faces of brickwork / concrete surfaces in cement mortar 1:4 surfaces finished even and smooth without using extra cement
Supply only integral water proofing compound
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F Wire netting of stainless steel wire 1.4mm dia 25mm mesh fixed with tinned tacks of stainless steel wire staples
Returning, filling in,soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm. all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & directed .
M & L for hardcore of broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Removing excavated material (soil) exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified and directed.
M&L PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
M&L 75 mm thick PCC1:3:6 type C- 1, using 20 mm graded stone aggregate, finishing concrete surfaes even and smooth without using extra cement in plinth protection complete all as specified and directed.
M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering, 10 mm thick on brick / concrete surfaces in cement mortar 1:4, surfaces finished even and smooth without using extra cement
M&L PCC 1:2:4 type B-0 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete.
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for following pipe of dia complete all as specified and as directed.
50mm bore
25mm bore
40mm bore
S&F for 50 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe .
S&F for 25 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe .
S&F for 40 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe .
S & F 5 HP Monoblok submersible pump non clog type including starter complete all as specified and directed.
S & F 5 HP Monoblok submersible pump clog type complete all as specified and directed.
S & F 3 core copper cable 4 Sqmm coplete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below groundevel) with top edge of the plate not less'than 1.5 metres below normalground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Cutting 80mm bore cast iron pipes and reducing to required length in position for Insertion of new tees, branches, etc all as specified & directed by Engineer-in Charge
M&L for Bends, tappers, Tee pieces (single & double branch) any type and angle/redious and straight connecting pieces of size 200mm to 300mm bore but all end flanged
Cutting of existing CI/GI /RCC Pipe of size 150/200/250/300 mm dia all as specified & directed by Engineer-in Charge
Supply, laying, testing & commissioning of 3 core 95 Sqmm HT 11 KV (Earthed) ISI Marked XLPE insulated screened PVC bedded, electric power cable (heavy duty) with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed.
Supply & Fixing and testing of 70 sq mm 3.5 core LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system in trenches, on poles and in ducts complete all as specified and directed by Engr in charge.
Supply & Fixing and testing of 10 sq mm 2 core LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system in trenches, on poles and in ducts complete all as specified and directed by Engr in charge.
Supply & laying of HDPE DWC pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/jain irrigation
Supply & laying of HDPE DWC pipe ISI mark of outer dia 110 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/jain irrigation
S&F PVC Junction box of size 200x175x100mm, IP 66 with hinged door including locking arrangment and MCB SP 6 Amp with necessary nut,bolt etc and including TPN aluminium bus bar mounted on insulators with suitable holes to provide incoming and outgoing LT cables and street light MCB complete all as specified and directed
M & L for PCC(1:2:4) type C-2 using 20mm grade stone aggregates for coping and similar work all as specified and directed.
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete( 1:2:4) etc complete all as specified and directed by Engineer-in-Charge. Note : Rate of mass concrete is included in quated rate.
M/L for GI Tubes,of size 80mm dia Medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Supply and fixing wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required 2x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (From PVC Junction box to Security light)
Supply and fix End cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm
Supply, installation, testing and commissioning of outdoor, of AC three phase , 50 HZ, 100 KVA capacity transformer step down , out door type 11000/433Volt (at No Load) copper wound , oil immersed , naturally cooled with external cooling tubes, core type delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol Dyn-11/vector group-4) with neutral brought on secondary (LV ) Side & having tapping in equal steps of 2.5% from (+) 5% to (-) 7.5% on primary side by means of hand operated off load tap change /correct LT voltage on secondary side including provision of all necessary / standard fittings mainly comprising of:- (a) One cable box on primary HV side having cable glands suitable for upto 3 core 120 sqmm XLPE 11 KV HT Cable consisting of 03 nos of porcelain HT bushing with brass/gun metal bushing rods complete with nuts and washers. (b) One cable box on secondary (LV) side consisting of 04 Nos porcelain bushing with GM bushing rods complete with GM nuts and washers with one nos of cable gland suitable for reception of out going LT PVC sheathed armoured cables of size upto 3.5 Core 240 sqmm. (c ) Oil conservator with filter type , drain valve and oil level gauge.
Item No 50 Contd/... (d) Dehydrating breather with first fill of dehydrating agent. (e ) Explosive Vents (f) Thermometer pocket on tank cover. (g) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centegrade with temp reading pointer, max temp indicator and resetting device. (h) Rating plate ith terminal markings. (j) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6mm GI Earth strip. (k) Oil Level gauge. (l) Oil Drain and filter valve (m) Oil filter hole with cap/plug with connections complete. (n) Lifting Lugs (o) Air Relief valve plug (p) Four plain solid cast steel detachable rollers. (q) First fill of fresh oil conforming to relevant IS and tested upto 40 KV dielectric strength.
Item No 50 Contd/... (r) Extra bushing for neutral outside the LT cable box for providing independant earthing for neutral. (s) Provision of 02 Nos of danger board 250x200mm size made out of 1.6 mm thick MS Plate, vitreous enameled white with letters, figures in marathi, Hindi and english of voltage and conventional skull and bones in signal red colour , one at HT side and other on LT side . (u) Any other fittings /accessories so as to conform the whole transformer to IS-2026.
S&F in vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one all as specified and as directed.
S&F of HT 11 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 65 KA and rupturing capacity 5 KVA and suitable for working pressure 9 KV RMS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one all as specified and as directed.
S&F drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one all as specified and as directed
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm all as specified and as directed. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
M & L for replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size
Supply, erecting and fixing in true vertical position of steel tubular swaged pole, 11 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-55, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of width 2 cm complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of length 2 m including taking down existing complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 40 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
Supplying and laying factory made unreinforced precast concrete cable cover ISI marked, class HV, type 1, flat of size 300 mm x 180 mm x 40 mm duly embossed with "HT CABLE 11 KV", laid lengthwise perpendicular to the axis of cable including pcc foundation (1:3:6) complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, botls, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or irected and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint all as specified and as directed.
M & L Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
M & L shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts all as per directed.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Supply and fix in New generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07, with luminaries 60 watt, with inbuilt surge protection 10 KV including 50 mm dia size of GI Bracket of length 1.2 Mtr, with Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting for connection of street light to over head conductor complete all as specified and directed.
M & L for fabrication of bus bar chamber suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 100 AMps ,4P,25 KA Busbar Capacity : 200 AMps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing : MCB TPN 63 Amps ,10 KA -01 MCCB 32 Amps ,4P,16 KA -01
M & L for fabrication of bus bar chamber suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 100 AMps ,4P,25 KA Busbar Capacity : 200 AMps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing : MCB 40 Amps ,4P,10 KA -04
M & L for fabrication of bus bar chamber suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 100 AMps ,4P,25 KA Busbar Capacity : 200 AMps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing : MCB TPN 63 Amps ,4P,10 KA -01 MCB TPN 40 Amps ,4P,10 KA -01
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 300 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specifid and directed.
Main Panel Incoming : - (i) MCCB 160 Amp adjustable type with , 4 Pole,50 KA - 01 No. (Ics=100%Icu) (ii) Digital maltifunction meter with CT– 01 No . (iv) Indicating lamp LED type one set in incoming phases.. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs. (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor. (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable. (viii) KWH meter CT operated as per suitable capacity of LT Panel. Outgoing ways :- i)MCCB 125 Amps adjudtable type ,4 pole,36 KA-01Nos (Ics=100%Icu ) ii)MCCB 63 Amps adjudtable type ,4 pole,36 KA-01Nos (Ics=100%Icu ) iii) MCB TPN 32 Amps,415 V, 4 pole,10 KA-02Nos
M&L for earthing with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to GI strip 32x6 mm by means of nuts, bolts and washers and encased in and including 15 dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 5 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on compeltion.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 50 x 50 x 6 mm thick angle iron frame flat iron 40 x6 mm cut length including drilling holes for fixing of nut and bolts to hold chain link fencing including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface complete all as specified and directed.
Supply only chain link fencing including line wires, any mesh, size dia 4 mm thick and steel wire mesh aperture 50 mm of standards, rails, straining bolts, etc.including necessary hooking binding cutting etc complete all as specified and directed by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
Supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation,returning and removing complete all as specified and directed.
M &L for construction of plinth (of size 2000mm x 2000 mm x 1500 mm) including excavation in trenchs in any type of soil,PCC 1:4: 8 in foundation fly ash bricks machinaryin cement mortor1 : 6 ,filling with moorum inside the plinth and RCC 1:2:4 over plinth including 16 mm bar reainfrocement with center to centre distane 100mm and external surface of masonary shall be plasterd with cement morter 1:4 and painted with weather coat paint ( double coat paint ) of shade as directed by Engr In Charge complete all as specified and directed by Engr in charge
Maruti Abhiyantriki (BID ID -3310557)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .