Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC FIRST FLOOR DOOR NO 3 BQ COMPLEX OPP GRAMAPANCHAYAT MALAYINKEEZHU P O THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695571 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.9 L+₹6,178.78 (0.79%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical L4 | |
| 4 | Rejected-Technical AROOR P O ALAPPUZHA KERALA 688534 | ALAPPUZHA | ALAPPUZHA | KERALA | 688534 | - | Rejected-Technical L3 | |
| 5 | Rejected-Technical | - | Rejected-Technical L5 |
| Sl No | Description | Qty | Unit | BOSS LIGHT L1 | KELTRON LIGHTING DIVISION L3 | D SURESH L4 | Alfa Electronics L2 | KERALA ELECTRICAL AND ALLIED ENGINEERING CO LTD (KEL) L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 2 m in depth, 2 m in width as well as 2.20 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 17.6 | cum | 375 ₹6,600 | 243.22 ₹4,280.67 | 208 ₹3,660.8 Lowest | 240 ₹4,224 | 210 ₹3,696 |
| 2.00 | 2.26.1 Extra for evry additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil | 4.41 | cum | 275 ₹1,212.75 | 201.32 ₹887.82 | 64 ₹282.24 Lowest | 220 ₹970.2 | 98 ₹432.18 |
| 3.00 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 0.8 | cum | 4,750 ₹3,800 Lowest | 6,410 ₹5,128 | 5,700 ₹4,560 | 18,000 ₹14,400 | 6,700 ₹5,360 |
| 4.00 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe?500D or more | 250 | kg | 110 ₹27,500 | 92.47 ₹23,117.5 | 75 ₹18,750 Lowest | 100 ₹25,000 | 95 ₹23,750 |
| 5.00 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 17.92 | sqm | 375 ₹6,720.75 | 315.41 ₹5,652.78 | 240 ₹4,301.28 Lowest | 500 ₹8,961 | 330 ₹5,914.26 |
| 6.00 | 5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 16.8 | cum | 650 ₹10,920 | 288.24 ₹4,842.43 Lowest | 7,200 ₹1,20,960 | 1,800 ₹30,240 | 8,490 ₹1,42,632 |
| 7.00 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m | 11.34 | sqm | 125 ₹1,417 Lowest | 243.22 ₹2,757.14 | 159 ₹1,802.42 | 280 ₹3,174.08 | 249 ₹2,822.66 |
| 8.00 | 90.15.2.4 Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 16 Meters | 2 | Nos | 2,08,000 ₹4,16,000 | 2,24,576.43 ₹4,49,152.86 | 2,10,000 ₹4,20,000 | 2,02,000 ₹4,04,000 Lowest | 2,17,000 ₹4,34,000 |
| 9.00 | 90.15,4,11 Supply conveyance, electrification, testing and commissioning oe 200 W LED flood light Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105 lumen /
W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than
0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,
acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up
for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80
certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 12 | Nos | 12,500 ₹1,50,000 Lowest | 13,000 ₹1,56,000 | 22,000 ₹2,64,000 | 14,500 ₹1,74,000 | 22,500 ₹2,70,000 |
| 10.00 | 0d265870/2020_2021 Supply and installation of Twin unit aviation LED obstruction light with stand yellow painted die cast aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED | 2 | Set | 5,500 ₹11,000 | 2,503.88 ₹5,007.76 | 3,500 ₹7,000 | 2,400 ₹4,800 Lowest | 3,490 ₹6,980 |
Tender Value
₹10.2 L
EMD Value
₹25,600
Closing Date
20 Nov 2024, 5:00 pmClosed
Superintending Engineer
Superintending Engineer, Corporation office Thiruvnanthapuram
Providing 2 nos Highmast lights in behind the Vettukad Church ( Madre- De -Devoos) at vettukad ward
2024_LSGD_705089_1
DB/62983/2024-25(80)
Open Tender
Electrical Works
Item Rate
90 days
Vettukadu
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Yes
₹25,600
Yes
21 Jan 2026
12 Nov 2024
22 Nov 2024
12 Nov 2024
20 Nov 2024
12 Nov 2024
Amount
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 2 m in depth, 2 m in width as well as 2.20 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1 Extra for evry additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe?500D or more
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m
90.15.2.4 Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 16 Meters
90.15,4,11 Supply conveyance, electrification, testing and commissioning oe 200 W LED flood light Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105 lumen / W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
0d265870/2020_2021 Supply and installation of Twin unit aviation LED obstruction light with stand yellow painted die cast aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.2.3 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
od265871/2020_2021 Supply and Laying 25 mm x 3 mm GI Strip at 0.5 metre below ground including connection/ terminating with GI nut, bolt, washer etc. as required
90.12.1.41 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
15.4.3 Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillar / Lighting DBs for automatic switching ON & OFF of street lights of sun set and sun rise or twillight override facility with 12/24 hour display formate with suitablebattery and indication for relay status i/c programing at site complete as required 3 output (1 output per phase) and suitable for three phase supply
OD54399/2022-2023: Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. size not less than 700x450x210mm
od265873/2020_2021 Supply of Meter Box made out of sheet Moulding Compound (430x265x170 mmsize) Surface mounted or recess in wall (Indoor / Outdoor Use) one piece moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt & earthing of the Meter box. Includes RCCb, HRC Fuse Base with Fuse link, 2 way neutral links, Providing OBO ( Switching Surge /Lightning Protection) for single phase connection. Earth wire, 2.5 sq mm ISI marked FRLS PVC insulated aingle core copper conductor cables as required
Alfa Electronics (BID ID -1983530)
KELTRON LIGHTING DIVISION (BID ID -1983051)
D SURESH (BID ID -1983280)
KERALA ELECTRICAL AND ALLIED ENGINEERING CO LTD (KEL) (BID ID -1983481)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .