Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.1 L+₹4.0 L (39.4%)Rejected-Finance 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹17.3 L+₹7.2 L (71.7%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | - | Rejected-Technical Slow prog in WLR |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
5 Mar 2020, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor
REPAIR AND MAINTENANCE TO CEILING FANS GEYSERS EXHAUST FANS AND MISC E M SERVICES AND REPAIR TO INTERNAL WIRING IN OTM MD ACCN AT SUNDERBANI UNDER GE NORTH AKHNOOR
2020_MES_322953_1
GE(N)/AKH-57/2019-20
Open Tender
Civil Works
Item Rate
180 days
Sunderbani
E Class Cat b i
8 documents required · 8 mandatory
₹500
GE North Akhnoor
₹36,000
Yes
6 Apr 2020
7 Feb 2020
7 Mar 2020
7 Feb 2020
5 Mar 2020
22 Feb 2020
Amount
Taking down ceiling fans of any make and size from ceiling fan hook, clean externally, opening for examination and overhauling complete by means cleaning of bearing, starter and rotor winding, providing new proper grade lubricant oil, grease and reassembling and re-fixing in same position or another position, complete all as specified & directed. Note :- (a) Replacement of defective spare parts and rewinding shall be measured and paid under relevant items catered here-in-after. (b) Repair shall be carried out at site of work.
Dismantling of existing worn out/burnt winding from ceiling fans of 1200 mm sweep and rewinding with super enameled copper wire of same existing size and class of insulation, varnishing with approved quality insulating varnish including replacement of split pins, locking nut, seal with nuts, bolts and washers, complete all as specified & directed. Note : Repair/rewinding of fans shall be carried out at contractors workshop & will be returned back & installed at its existing or new location as directed after carrying out repair/rewinding work.
All as per Srl item No.2 above but for 1400 mm sweep.
Ball bearing of ceiling fans of size No.6200 including dismantling/taking down old unserviceable ball bearing, complete all as specified & directed. Make : SKF/ NBC
Ball bearing of ceiling fans of size No.6201 including dismantling/taking down old unserviceable ball bearing, complete all as specified & directed. Make : SKF/ NBC
Ball bearing of ceiling fans of size No.6202 including dismantling/taking down old unserviceable ball bearing, complete all as specified & directed. Make : SKF/ NBC
Ball bearing of ceiling fans of size No.6203 including dismantling/taking down old unserviceable ball bearing, complete all as specified & directed. Make : SKF/ NBC
Gun metal bush for ceiling fan 1200/ 1400 mm sweep including dismantling/taking down old unserviceable bush, complete all as specified & directed.
Condenser/ capacitor (Old fitted) of 2.5 MFD for ceiling fans including dismantling/taking down old unserviceable condenser/capacitor, complete all as specified & directed. Make : Bajaj/ Crompton/ GEC/ Khaitan/ Orient
Condenser/ capacitor (Old fitted) of 3.15 MFD for ceiling fans including dismantling/taking down old unserviceable condenser/capacitor, complete all as specified & directed. Make : Bajaj/ Crompton/ GEC/ Khaitan/ Orient
Condenser/ capacitor (Old fitted) of 4.00 MFD for ceiling fans including dismantling/taking down old unserviceable condenser/capacitor, complete all as specified & directed. Make : Bajaj/ Crompton/ GEC/ Khaitan/ Orient
Fan regulator, deluxe socket type (electronic step type) for 1200/1400 sweep AC ceiling fan including taking down old unserviceable fan regulator, complete all as specified and directed.
PVC canopy upper & down side suitable for 1200/1400 sweep AC ceiling fan including taking down old unserviceable PVC canopy, complete all as specified and directed.
Down rod with coupling socket suitable for ceiling fan of size 1200 mm/1400 mm sweep of any type/make including taking down old unserviceable down rod, complete all as specified and directed.
Hanging clamps complete with rubber rest, nut bolt etc suitable for ceiling fan of size 1200 mm/1400 mm sweep of any type/make including taking down old unserviceable hanging clamp, complete all as specified and directed.
Split pins suitable for ceiling fan of size 1200 mm/1400 mm sweep of any type/make including taking down old unserviceable split pins, complete all as specified and directed.
Machinery screw any type suitable for ceiling fan of size 1200 mm/1400 mm sweep of any type/make including taking down old unserviceable screw, complete all as specified and directed.
Fan blade set suitable for ceiling fan of size 1200 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
Fan blade set suitable for ceiling fan of size 1400 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
Taking down exhaust fans of any make and size from wall, clean externally, opening for examination and overhauling complete by means cleaning of bearing, starter and rotor winding, providing new proper grade lubricant oil, grease and reassembling and re-fixing in same position or another position, complete all as specified & directed. Note :- (a) Replacement of defective spare parts and rewinding shall be measured and paid under relevant items catered here-in-after. (b) Repair shall be carried out at site of work.
Dismantling of existing worn out/burnt winding from exhaust fans of 230 upto 375mm sweep and rewinding with super enameled copper wire of same existing size and class of insulation, varnishing with approved quality insulating varnish including replacement of split pins, locking nut, seal with nuts, bolts and washers, complete all as specified & directed. Note : Repair/rewinding of exhaust fans shall be carried out at contractors workshop & will be returned back & installed at its existing or new location as directed after carrying out repair/rewinding work.
All as per Srl item No.21 above but for 375 to 450 mm sweep.
Ball bearing of exhaust fans of size 230mm upto 375mm sweep including dismantling/taking down old unserviceable ball bearing, complete all as specified & directed. Make : SKF/ NBC
Ball bearing of exhaust fans of size 375mm to 450mm sweep including dismantling/taking down old unserviceable ball bearing, complete all as specified & directed. Make : SKF/ NBC
Capacitor for exhaust fans of 230mm to 375mm sweep including dismantling/taking down old unserviceable capacitor, complete all as specified & directed. Make : Bajaj/ Crompton/ GEC/ Khaitan/ Orient
Fan blade set suitable for exhaust fan of size 230 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
Fan blade set suitable for exhaust fan of size 275 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
Fan blade set suitable for exhaust fan of size 300 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
Fan blade set suitable for exhaust fan of size 380 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
Fan blade set suitable for exhaust fan of size 450 mm sweep of any type/make including taking down old unserviceable fan blade, complete all as specified and directed.
MS louvers/ mounting fixtures, shuttering complete suitable for fixing/ mounting of exhaust fans on wall of size 230mm to 450mm sweep including MS nuts, bolts & washers of suitable size for fastening/ tightening the fixtures on walls, complete all as specified & directed.
Taking down water heater, storage type after unscrewing the nuts from grouting bolts and disconnecting of water connection of any type and capacity 25/50 ltrs, taking out the tank after unscrewing the screw of the body cover, cleaning, descaling of inner tank and assembly by using HCL ,making the tank leak proof by welding, brazing or by any other suitable method, re-assembling and fixing back at its original position and testing, complete all as specified & directed.
Taking out damaged geyser assembly/ apparatus plate of storage type water heater of capacity 25/ 50 ltrs after unscrewing nuts, bolts and screws, complete all as specified & directed.
Geyser assembly/ apparatus plates storage type water heater of capacity 25 ltrs including rubber washer, nuts and bolts of any type and make, complete all as specified & directed.
Geyser assembly/ apparatus plates storage type water heater of capacity 50 ltrs including rubber washer, nuts and bolts of any type and make, complete all as specified & directed.
Geyser element having round/ clip/ triangle in storage type water heater of any size and type of capacity 1500 watt including taking down old unserviceable heating element, complete all as specified & directed.
Geyser element having round/ clip/ triangle in storage type water heater of any size and type of capacity 2000 watt including taking down old unserviceable heating element, complete all as specified & directed.
Geyser element along having space for thermostate with base round/ clip/ triangle in storage type water heater of any size and type of capacity 1500 watt including taking down old unserviceable heating element, complete all as specified & directed.
Thermostat in storage type water heater of any size and type including taking down old unserviceable thermostat, complete all as specified & directed.
PRV (Pressure release valve) for the safety of geysers of any type/size including taking down old unserviceable PRV, complete all as specified & directed.
Bottom cover of outer tank suitable for geyser of 25 ltrs capacity including taking down old unserviceable bottom cover, complete all as specified & directed.
Bottom cover of outer tank suitable for geyser of 50 ltrs capacity including taking down old unserviceable bottom cover, complete all as specified & directed.
Internal tank made of copper heavy duty gauge in geyser of capacity 25 litre with double lapped joint suitable for geyser of any type/make with necessary screws, nuts, bolts gasket etc including dismantling/taking down old unserviceable internal tank, complete and all as specified & directed.
Internal tank made of copper heavy duty gauge in geyser of capacity 50 litre with double lapped joint suitable for geyser of any type/make with necessary screws, nuts, bolts gasket etc including dismantling/taking down old unserviceable internal tank, complete and all as specified & directed.
Indicating lamp red/green type as per existing size and shape including taking down old unserviceable lamp, complete all as specified & directed.
Plug top 3 pin 16 amp, complete all as specified & directed.
PVC insulated copper flexiable wire of size 40/0.0076, 3 core including taking down old unserviceable flexiable wire, complete all as specified & directed.
Non return valve of cast copper alloy, 15 mm bore (ISI marked) including all jointing materials, fixed in repairs, complete all as specified & directed.
Stop valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
GI union of size 15mm bore (ISI marked), fixed in repairs, complete all as specified & directed.
GI socket of size 15mm bore (ISI marked), fixed in repairs, complete all as specified & directed.
GI reducing socket of size 20 x 15mm bore (ISI marked), fixed in repairs, complete all as specified & directed.
GI tee (equal) of size 15mm bore (ISI marked), fixed in repairs, complete all as specified & directed.
GI nipple of size 15mm bore (ISI marked), fixed in repairs, complete all as specified & directed.
PVC connection heavy duty of 15mm size with PTMT nuts on both ends of length 750mm including taking down old unserviceable PVC connections of any size from storage type water heater after unscrewing the nuts from GI pipe and storage type water heater, complete all as specified & directed.
PVC connection heavy duty of size 15mm, spirally reinforced with stainless steel wire inside the pipe for outlet of hot water pipe connection with brass nuts at both ends of length 750mm including taking down old unserviceable PVC connections of any size from storage type water heater, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Sub main wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in and including PVC casing caping of 20/30mm, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, surface type on walls, roofs etc including one run of 4.00 Sqmm FRLS PVC insulated copper conductor for earth continuity wire in green color , complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC casing caping will be measured and paid as one unit only.
Air termination single pointed aluminum rod 12mm dia and 300mm long including taking down old unserviceable air termination rod, complete all as specified & directed.
Aluminium strip of 25x3mm for extension of earth and connected to equipment or panel by means of bolts, nuts and washers, buried in ground or drawn in conduit/pipe or fixed to pole including taking down old unserviceable strip, complete all as specified & directed.
Copper strip of 32x6mm for extension of earth and connected to equipment or panel by means of bolts, nuts and washers, buried in ground or drawn in conduit/pipe or fixed to pole including taking down old unserviceable strip, complete all as specified & directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw including taking down old unserviceable test point terminal block, complete all as specified & directed.
Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including galvanised iron earth strip of 32x6mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm 10cm long, PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) complete with necessary earth work in any type of soil, removal including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of required size, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 40mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if desired earth resistance is not obtained, earthing will be regenerated at no extra cost.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switches, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down unserviceable service connection wire.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC casing and caping 'ISI marked' of 20/30mm size as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories, fixing arrangements on wall /roof/floor by means of drilling by heavy duty hand drill and fixing with PVC rawl plug and screws including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan point controlled by one way switch, complete all as specified & directed.
All as per Srl item No. 67 above but for one 3/5 pin 5 Amps socket outlet on same board .
All as per Srl item No. 67 here-in-before but for one 3/5 pin 5 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC casing and caping 'ISI marked' of 20/30mm size as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories, fixing arrangements on wall /roof/floor by means of drilling by heavy duty hand drill and fixing with PVC rawl plug and screws including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent, complete all as specified & directed.
Notes for Srl Item No. 67 to 70 (i) Unit rate includes for cutting chases whereever required and sinking for boxes, making good to walls / floors etc., complete, including white wash / colour wash as directed. (ii) Uniform coding of wiring i.e red / yellow / blue for phase black for neutral and green for earth is to be maintained.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, complete all as specified & directed.
Switch piano flush type 5 Amps 240 Volt, single pole one way, complete all as specified & directed.
Bell push flush type, one way 5 Amps single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, complete all as specified & directed.
Socket outlet two in one, 5 pin type, 5 Amp, flush type, complete all as specified & directed.
Fan regulator, deluxe socket type (electronic step type) for 1200/1400 sweep AC ceiling fan including taking down old unserviceable fan regulator, complete all as specified and directed.
Bell, Ding Dong AC. 230 volts, single pole, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
LED lamp in white colour of 7 watt, 230 volt 50 Hz complete all as specified & directed. Make : Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya/ Havells
Sheet metal enclosure, factory made for DBs, protection class IP-36, phosphatised powder coated, double door when MCB's to be used, single pole & neutral, 240 volts with 200 amps rated copper bus bar & neutral link earthing stud, 12 way, complete all as specified & directed.
Sheet metal enclosure, factory made for DBs, protection class IP-36, phosphatised powder coated, double door when MCB's to be used, single pole & neutral, 240 volts with 200 amps rated copper bus bar & neutral link earthing stud, 8 way, complete all as specified & directed.
Sheet metal enclosure, factory made for DBs, protection class IP-36, phosphatised powder coated, single door when MCB's to be used, single pole & neutral, 240 volts with 200 amps rated copper bus bar & neutral link earthing stud, 4 way, complete all as specified & directed.
MCB, single pole & neutral, 35 to 60 Amp, AC, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, AC, 10 KA repturing capacity, 240 Volt, 'B' series, complete all as specified & directed.
Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Surface & wall mounted, LED tube light fitting, 20W, glare free, smooth light distribution, 230v, box type, epoxy powder coated CRCA sheet housing with reflector cover channel, aesthetic looking end cap and HPF LED driver with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified & directed. Make. Havells, Cat Part No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
Energy saving 10W LED bulk head luminaires, IP-65, oval shape, surface mounted with all other accessories prewired and making connections with copper flexible twisted twin cord of appropriate gauge and length,230v, 50Hz including taking down old unserviceable fitting including taking down old unserviceable fittings, complete all as specified & directed. Make. Havells, Cat Part No.RUGBYNEONFT10WLED760SSYMBOPC or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular including taking down old unserviceable service connections, complete all as specified & directed.
Ditto all as per item No 90 but of size 16 Sqmm 2 Core.
Repairing of tube light fitting 1x36/40 watt by replacement of the spares like electronic ballast bi pin holders complete all as specified and directed incld wiring with suitable size wire. Note : Spares will be measured and paid seperately.
Electronic ballast suitable for FTL fitting of 36/40 watt
Bi pin holders
Recess mounting LED light fitting, flat panel 34W LED 6000K, 230 volts, 2’x2’ luminaire, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling complete including making connection with PVC copper conductor cable of appropriate size taking down old unserviceable light fittings, complete all as specified & directed. Make. Havells, Cat Part No. PLUTONE O2X2PLR34WLED857S or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
M/S K K ENTERPRISES
M/s Mool Raj Romesh Chander
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .