Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹13.0 L
EMD Value
₹13,100
Closing Date
27 Nov 2026, 6:00 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Officer Kadi nagarpalika
PROVIDING AND FIXING OF LED STREET LIGHTING IN SARDAR BAUG FOR KADI NAGARPALIKA, KADI. DIST. MAHESANA UNDER 15TH FINANCE COMMISSION 2025-26 GRANT.
364366
1313/5/2026-27
Open
Electrical - All
Works
Mehsana
11 documents required · 11 mandatory
₹1,062
Chief Officer Kadi nagarpalika
₹13,100
7 Nov 2026
7 Nov 2026
7 Nov 2026
27 Nov 2026
7 Nov 2026
120 days
DIST. MAHESANA UNDER 15TH FINANCE COMMISSION 2025-26 GRANT.
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
1 660.00 Supplying and erecting Flexible PVC insulated multi 73.73 Rupees Seventy Three and Rmt.
strand multi core 1.1 kv grade ISI marked copper Seventy Three Paise
wires of following size to be erected as directed.
h) 2.50 Sq.mm 3 core round PVC sheathed
2 110.00 Supplying and erecting LED street light / Flood light 3345.12 Rupees Three Thousand Three Each
fittings with High power White LEDs wattage of 3 Hundred Forty Five and Twelve
Watt and above assembled on single MCPCB, Paise
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company
mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply
with over-voltage protection.
(i) above 36 to 48 Watts
3 110.00 providing and erecting Miniature circuit breaker 112.11 Rupees One Hundred Twelve and No
single pole 6A to 25A suitable to operate on 240 V Eleven Paise
A.C. system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS
8828/1996 with ISI Mark
4 55.00 Plastic Enclosurefitted with DIN Rail suitable for 52.52 Rupees Fifty Two and Fifty Two No
incorporating one / Two nos. MCB Paise
5 55.00 Providing and erecting Pipe type earthing having 150 368.65 Rupees Three Hundred Sixty No
cms.long and 2.5 cms. dia. galvanised iron pipe with Eight and Sixty Five Paise
coupling and buch buried in specially prepared earth
pit complete with necessary 8 SWG earth wire.
6 55.00 for using salt and charcoal/coke as required for pipe 171.70 Rupees One Hundred Seventy No
type earthing One and Seventy Paise
7 1870.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI 124.23 Rupees One Hundred Twenty Mtrs.
armoured cable multistrand / Solid Aluminium Four and Twenty Three Paise
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
(b) 4 core 6 Sq. mm
8 1650.00 Making trench in soft soil of suitable width of 90 cm 46.46 Rupees Forty Six and Forty Six Mtrs.
deep for laying cable or locating the fault all over the Paise
run and back filling the same and making the surface
as normal ground.
KADI NAGARPALIKA
PROVIDING AND FIXING OF LED STREET LIGHTING IN SARDAR BAUG FOR KADI NAGARPALIKA, KADI.
DIST. MAHESANA UNDER 15TH FINANCE COMMISSION 2025-26 GRANT.
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
9 1760.00 Providing & laying approved make Double walled 62.62 Rupees Sixty Two and Sixty Two mtr.
corrugated pipes (DWC) of polyethylene(conforming Paise
to IS 14930 II )with necessary connecting accessories
of same material at required depth in existing trench
for laying of cable. below ground / road surface for
enclosing cable
(A)50 mm outer dia
10 110.000 Providing and, fixing heavy duty flange type brass 38.38 Rupees Thirty Eight and Thirty No
cable gland with rubber ring for PVC insulated Eight Paise
armoured cable complete with out going tails,
insulating tape etc for following size of cables.
B) 2 to 4 core - 6.0 Sq.mm.
11 440.00 Solder less crimping type Aluminium lugs conforming 6.06 Rupees Six and Six Paise NO
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
12 55.00 Supplying and erecting approved make Octagonal 5556.01 Rupees Five Thousand Five No
pole made from HR sheet steel. The pole should be Hundred Fifty Six and One Paisa
made as per IS. and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box
consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable
foundation (Included) as per details given by
manufacturer considering site requirement.
(B) 4 Mtr. Long 70 mm Top X 130 mm bottom dia,
mm thickness with 200mmX200mmX12mm base
plate, 4-M16 Bolts and 450mm long with necessary
G.I. J Bolts .Approx weight 37 kg
13 55.00 Providing M-20 / 1:2:4 cement concrete foundation & 809.01 Rupees Eight Hundred Nine and No
70 % PCC from bottom including excavation for the One Paisa
pole of size 45 x 45 x 100 cms. Deep in below ground
level with plinth of 45 cms x 45 cms (or 45 cms dia x
45 cms) high upper ground level with necessary
curing and finishing in approved manner.
( for 4 & 6 mtr pole)
14 55.00 Supplying & Erectig Sintex or approved make SMC 515.10 Rupees Five Hundred Fifteen and No
press moulded composite FRP (Plastic) loop-in, loop- Ten Paise
out box aprox. 207 mm thick complete with bakelite
connector strip 4way & hinged doors having locking
arrangement with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable
clamps & earth bolt of following size of box.
(b) 250 mm X 200 mm X 100 mm (Deep).
KADI NAGARPALIKA
PROVIDING AND FIXING OF LED STREET LIGHTING IN SARDAR BAUG FOR KADI NAGARPALIKA, KADI.
DIST. MAHESANA UNDER 15TH FINANCE COMMISSION 2025-26 GRANT.
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
15 25.000 Providing and erecting street light pole bracket 561.56 Rupees Five Hundred Sixty One No
comprising main B Class MS pipe of 4.2 cm/require and Fifty Six Paise
outside dia. complete with suitable B Class M.S.
sleeve tubing of approx. 45cms.length and suitable for
76.5 mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and having
spread of 1 mtr. length with suitable rise as per site
condition & suitable welded stiffener reducer and
nipple with check nut complete painted with one coat
of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of
[A] Single Arm bracket 1 Mtr
16 30.000 Providing and erecting street light pole bracket 758.51 Rupees Seven Hundred Fifty No
comprising main B Class MS pipe of 4.2 cm/require Eight and Fifty One Paise
outside dia. complete with suitable B Class M.S.
sleeve tubing of approx. 45cms.length and suitable for
76.5 mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and having
spread of 1 mtr. length with suitable rise as per site
condition & suitable welded stiffener reducer and
nipple with check nut complete painted with one coat
of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of
[B] Double Arm Bracket 1 Mtr
One percent of the Estimated cost of work put to tender shall be recovered from the running bills of the contractor as testing charges, after deducting
the cost of material proposed in scheduled-A at basic rate. One percent labour cess will be deducted from contractor’s bill.
I/ We am/are willing to carry out the work at _____________________% above / below _____________________________%
(should be writtern in figure and words)
below / above the estimated rates mentioned above amount of my / our tender works out as under :-
Estimated amount put to tender : Estimated amount put to tender :
Signature of contractor CHIEF OFFICER
KADI NAGARPALIKA
1) All the work shall be carried out as per MOST specification and specification on the division or as directed.
Rates quoted includes clearance of site (prior to commencement of work and at its closed) in all respects and held gross for under all conditions, site moisture
KADI NAGARPALIKA
PROVIDING AND FIXING OF LED STREET LIGHTING IN SARDAR BAUG FOR KADI NAGARPALIKA, KADI.
DIST. MAHESANA UNDER 15TH FINANCE COMMISSION 2025-26 GRANT.
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated in Figure in Words according to
but may be estimated
more or less quantities.
In RCC item when there is change in grade of concrete mix or change in consumption of cement as per actual mix design then the difference in consumption of
cement shall be deducted from the rate of original item valued at the star rate as mentioned in tender. However no extra payment shall be made for use of
additional Quantity of cement as per actual concrete mix design. Concrete mix design shall be done in GERI laboratory only.
The Contractor shall exhibits a board as per Govt. circular No. 2DK – 3277 / 1657 N Dt. 26–01-73 with detail of specification and details of work and amount
4) involved at site without any payment as directed by the Engineer in charge.
Testing of materials be as per statement attached with the Specifications, the materials shall be tested in G.E.R.I. Bill for testing shall be paid by the CHIEF
5) OFFICER and 1% of the (one percent) of amount put to tender after shall be recovered from the running account bills of the works. (As per G.R. (R&B) Deptt.,
6) The contractor shall quote even "NIL" if no reduction is proposed.
One precent of estimated cost put to tender for this work shall be recovered from the contract payments as "LABOUR CESS". In terms of the Gujarat
7) Government Gazette Extra ordinary dated 12.12.04. Implementation of building and other construction workers regulation of equipments and conditions of
service Act-1996)
8) Photographs of before work and after work will be submitted by the contractor at the time of each bill submission.
The contractor is solely responsible to bare all applicable taxes excluding GST. and department will not entertain any contractor representation to reimburse
9) any financial burden due to applicable taxes.
Signature of contractor CHIEF OFFICER
KADI NAGARPALIKA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
00 TITLE Page.pdf
01. Tender Notice.pdf
02 Technical Bid (1).pdf
03 Form B1.pdf
12 Test Require For Construction Material.pdf
13 Specifications of Electrical Work.pdf
14 General Specification of Electrical Wiring in Govt Building.pdf
15 Electric Volume C 2012-2013.pdf
16 E2 Electrical Make List.pdf
17. Price bid.pdf
18. Schedule B .pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .