Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC CHOLAKKAPARAMBAN | KOTTAYAM | KERALA | 686102 | L1 | Accepted-AOC Accepted Vide Resolution No.5 (1) dtd. 13/03/2026 Of Edarikode GP | |
| 2 | L2₹31.8 L+₹72,680.20 (2.34%)Rejected-AOC | L2 | Rejected-AOC Higher rate and hence the tender is not admitted |
| Sl No | Description | Qty | Unit | JAYESH L2 | UNNIKRISHNAN K L1 |
|---|---|---|---|---|---|
| 1.00Road work | |||||
| 1.00 | 3.2:Preparation of Foundation for Embankment <br> Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means <br> Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. | 1,980 | sqm | 14.7 ₹29,106 | 14 ₹27,720 Lowest |
| 1.00 | OD470485/2025-2026:[OD From MORD 4.1.A.1] Granular Sub-base with Well Graded Material (Table 400.1) (A)
By Mix in Place Method Construction of granular sub-base by providing well graded material,
spreading in uniform layers with motor grader on prepared surface, mixing by mix in place
method with rotavator at OMC, and compacting with Plate Vibrator to achieve the desired
density, complete as per Technical Specification Clause 401. (i) For Grading I Material | 207.46 | cum | 3,077 ₹6,38,354.42 | 3,007 ₹6,23,832.22 Lowest |
| 1.00 | OD470486/2025-2026:[OD From MORD 75.8.1] Providing plain/reinforced concrete(1 cement:2 fine aggregate: 4
course aggregate) for substructure as per drawings and technical specifications Clause 802, 803,
1202 & 1203as required including compaction, finishing and tamping etc .complete. Max. size
of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per
specification
(i) Nominal mix (1:2:4) | 297 | cum | 8,446 ₹25,08,462 | 8,255 ₹24,51,735 Lowest |
| 1.00 | OD478807/2025-2026: Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed
over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with
area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and
supported on GI pipe pole 50mm NB-2 nos confirming to IS 1239 firmly fixed to the ground by
means of properly designed foundation with M 15 grade cement concrete min size 40 cm x
40cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of
epoxy painting over epoxy primer and as per approved drawing and clause 801 including
lettering symbols etc. (Derived from MoRD spec 10.3.A.2) | 0.9 | sqm | 2,800 ₹2,520 | 2,750 ₹2,475 Lowest |
Tender Value
₹31.8 L
EMD Value
₹50,000
Closing Date
9 Mar 2026, 5:00 pmClosed
RESHMA VP
Office of the Assistant Engineer, LID AND EW Section , Edarikode Grama Panchayat
CMLRRP Project 2024-25 Thirurangadi LAC SI No.4108-Vailikulamb Road Improvement-Edarikode GP-Malappuram District
2026_LSGD_841907_1
TDR05/AE/LIDEW/EKD/2025-26
Open Tender
Civil Works - Roads
Item Rate
180 days
EDARIKODE GRAMA PANCHAYAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
29 May 2026
2 Mar 2026
11 Mar 2026
2 Mar 2026
9 Mar 2026
2 Mar 2026
Road work
3.2:Preparation of Foundation for Embankment <br> Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means <br> Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
OD470485/2025-2026:[OD From MORD 4.1.A.1] Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with Plate Vibrator to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
OD470486/2025-2026:[OD From MORD 75.8.1] Providing plain/reinforced concrete(1 cement:2 fine aggregate: 4 course aggregate) for substructure as per drawings and technical specifications Clause 802, 803, 1202 & 1203as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
OD478807/2025-2026: Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB-2 nos confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 40 cm x 40cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. (Derived from MoRD spec 10.3.A.2)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1420079.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tendernotice_2.pdf
PDF • 0.25 MB
Tendernotice_3.pdf
PDF • 0.07 MB
FOT.pdf
Tender Documents • 0.25 MB
PAG.pdf
Tender Documents • 0.26 MB
BOQ_1420079.xls
BOQ • 0.30 MB
SBD.pdf
Tender Documents • 1.69 MB
AFDVT.pdf
Tender Documents • 0.24 MB
coregendam.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .