Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC DHARMANAGAR TRIPURA WEST | ₹1.1 Cr | L1 | Accepted-AOC AS PER NIT |
| 2 | L2₹1.3 Cr+₹18.0 L (15.9%)Rejected-AOC COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | ₹1.3 Cr+₹18.0 L (15.9%) | L2 | Rejected-AOC AS PER NIT |
| 3 | L3₹1.4 Cr+₹21.8 L (19.3%)Rejected-AOC | ₹1.4 Cr+₹21.8 L (19.3%) | L3 | Rejected-AOC AS PER NIT |
| 4 | L4₹1.4 Cr+₹24.7 L (21.8%)Rejected-AOC AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | ₹1.4 Cr+₹24.7 L (21.8%) | L4 | Rejected-AOC AS PER NIT |
| 5 | L5₹1.4 Cr+₹26.5 L (23.4%)Rejected-AOC AGARTALA TRIPURA W | AGARTALA | TRIPURA | ₹1.4 Cr+₹26.5 L (23.4%) | L5 | Rejected-AOC AS PER NIT |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
18 May 2022, 5:00 pmClosed
DGM, ED-Dharmanagar
DGM, ED-Dharmanagar
Extension of HT/LT line and Construction of Substation under ED Dharmanagar
2022_POWER_28056_1
NIT/ED-DMR/22-23/01, dated 25.04.2022
Open Tender
Electrical Works
Turn-key
180 days
Jurisdiction under ED-Dharmanagar
As per NIT
3 documents required · 3 mandatory
₹10,000
Yes
₹2.6 L
Yes
Chamber of the DGM, ED-Dharmanagar
26 Aug 2022
27 Apr 2022
19 May 2022
28 Apr 2022
18 May 2022
11 May 2022
28 Apr 2022 - 2 May 2022
4 May 2022
Amount
SCHEDULE - A Supply
9 mtr. Long PCC pole
8 mtr. Long PCC pole
Stay set Complete
Stay wire 7/2.5mm
Stay insulator(HT)
Stay insulator (LT)
LT Shackle insulator
Straps with Nuts & Bolts
MS Channel 100X50X50X6 mm
MS Channel 75X40X40X6 mm
MS Angle 65X65X6 mm
MS Angle 50X50X6 mm
11 KV Polymer pin insulator
11 KV polymer disc insulator
11 KV Disc fittings
ACSR (6/1/2.59mm)
GI wire 8 SWG
11 KV GOS unit(3-phase)
11 KV DOF unit (3-phase)
11 KV polimeric L.A.(9 KV, 5KA)
100 Amp Cut out
40 mm dia GI pipe 2.5 mtr long (Make:-TATA/JINDAL)
60 kg salt 7 55 kg Charcoal (For 1 pit)
LT 95 sq.mm PVC cable
LT 16 sq.mm. PVC cable
M.S. Nuts & Bolts i/c washer, ISI markedmachine made(assorted size)
Stay Clamps of MS Flat (50X6mm)
Febricated Brackets clamps of MS Flat (50X6mm)
11 KV Danger Plate (HT)
11 KV Danger Plate (LT)
Wooden plank 1X0.25X0.038 mtr, (local Teak wood) for cut out
Bimetalic Lugs (Assorted Size)
95sq.mm., 11 KV grade 3 core XLPE cable
100 Dia GI pipe i/c necessary clamps, Nuts & Bolts
HDPE pipe, PE-100 grade, PN-8(SDR-17), 110 mm dia, wall thickness:minimum-6.5 mm, maximum 7.3mm
Reel insulator
SCHEDULE -B Erection
Erection of 9 mtrs length of PCC pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect .
Erection of 8 mtrs length of PCC pole at any kind of soil upto a depth of 1/6th of pole height , i/c excavation of earth , refilling the pit with soil upto the ground level, ramming and making complete in all respect i/c Hand-cart carriage & mannual carriage with necessary loading & unloading.
Erection of stay set direct in earth complete with 19mm X 1800mm long stay rod , anchor plate of size 300X300x8 mm , thimble, turn buckle, 7/2.5mm dia GI stranded stay wire and stay insulator etc.with supply of MS clamp, nuts 7 bolts etc as required and making complete in all respect .
Erection of MS Channel cross arm 2.8 mt.long 100X50X50X6 mm for Sub-Station bracket (for line & txr base)
Erection of MS Channel cross arm 0.6 mt.long 100X50X50X6 mm for Sub-Station bracket ( for Txr base)
Erection of MS Channel cross arm 2.8 mt.long 75X40X40X6 mm for Sub-Station bracket (for GOS & DOF)
Erection of MS angle cross arm 2.8 mt.long 65X65X6 mm MS angle for Sub-Station bracket (for GOS Handle)
Erection of MS angle cross arm 3.1 mt.long 65X65X6 mm MS angle for Sub-Station Guard bracket
Erection of MS Channel cross arm 0.3 mt.long 75X40X40X6 mm (SP Top Bracket for 11KV line)
Erection of MS Channel cross arm 1.2 mt.long 75X40X40X6 mm (SP Bottom Bracket for 11KV line)
Erection of MS angle cross arm 1.5 mt.long 65X65X6 mm ( SP guard Bracket for 11KV line)
Erection of MS Channel cross arm 1.2 mt.long 75X40X40X6 mm (DP Top Bracket for 11KV line)
Erection of MS Channel cross arm 1.6 mt.long 75X40X40X6 mm (DP Bottom Bracket for 11KV line)
Erection of MS angle cross arm 1.7 mt.long 65X65X6 mm ( DP guard Bracket for 11KV line)
Erection of MS angle cross arm bracket for LT line upto 1.2 mtr. Long of 50X50X6 mm
Erection of shackle insulator of size 75 mm X 90 mm/ 100 mmm X15mm with straps & bolts/ clamps on poles
Erection of 11 KV Polymer pin insulator
Erection of 11 KV polymer disc insulator set alongwith necessary fittings
Laying & stringing of 1 km (single conductor ) ACSR 6/1/2.59mm dia weasel i/c hoisting & binding etc. complete as reqd.
Laying & stringing of 1 km (single conductor ) 8 SWG GI wire i/c hoisting & binding etc. complete as reqd.
Erection of 11 KV 200 Amps GOS unit set of three nos i/c necessary connection complete as per technical specification
Erection of 11 KV DOF unit set of three nos i/c necessary connection complete as per technical specification
Erection of 9 KV, 5KA single pole metal oxide gapless type i/c necessary connection complete as per technical specification
Installation / positioning of 11/0.430 KV , 3-phase 63 KVA of distribution transformer on pole with necessary connection and fitting fixing of all allied assessories components as required for making complete in all respect for energizing
Earthing with GI pipe 2.5 mtr. Long and 40 mm dia i/c excavation , refilling with alternate layer of salt and charcoal as per drawing
Laying of 8 SWG GI wire at 300 mm below the ground level for earthing of sub-station equipments from the earth electrode.
Providing 3 phase service connection with laying PVC cable from nearby electrical pole to premises upto 35 mtr. In length supported by GI wire, reel insulator i/c fitting fixing of energy meter as required.
Febrication of cross arms by MS Channel/ MS Angle as per specification
Erection of Danger plate on OH lines (11KV/415 volts)
Laying of 01 no. PVC insulated and PVC sheathed /XLPE power cable of 11 KV grade of following size direct in ground i/c excavation , sand cushioning , protective cover and refilling the trench etc. as required. Trench size: Width- 350mm, Height- 1200 mm, Sand(cushioning) : Height-250mm, Width- 350mm. Protection: double layer bricks. Upto 120 sq.mm.
Laying and fixing 100 mm dia GI pipe (medium class) in ground complete with GI fittings i/c trenching (120 cm depth) and refilling etc as required
Laying of 01 no. PVC insulated and PVC sheathed /XLPE power cable of 11 KV grade of all size in the GI pipe / HDPE for riser i/c tieup of pipe with pole by the help of MS flat clamp as required. Upto 400 Sq.mm.
Providing protective Sub-Station fencing of size 2.5X3.5 mtr and 1.5 mtr height. Fencing by 75X25 mm wire mesh, 10 nos MS angle post (50X50X6mm) of height 2 mtr, horizontal bar 4X2.5 mtr, 2X3.5 mtr, 2x2 mtr, 2X1.5 mtr and 10X1.5 mtr vertical bar of MS flat (35X6mm). a single part of MS grill door of size 1.5 X 1.2 mtr along with necessary locking arrangement i/c grouting and painting by aluminium paint over red oxide priming of approve quality as required as per technical specification i/c supply of all materials.
Carriage of 11/0.430 KV, 3-phase, 63 KVA by mechanical transport from the site/store/workshop to working site vis-à-vis i/c loading, unloading, and placeing on base as required upto the lead range of 250 km.
Supply and making outdoor cable and termination with heat shrinkable jointing kit complete with all accessories i/c lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: Upto 150 sq.mm.
Erection of 11 KV protective guarding by GI wire 8 SWG as per technical specification, across road/river/telecom line etc. in horizontal formation complete
Erection of 11 KV protective guarding/ Cross lacing for 415/240 volt line by GI wire 8/10 SWG as per technical specification, across road/river/telecom line etc. in horizontal/vertical formation complete with spool/ reel insulator.
Providing of precast cement concrete cable identification route marker (1 cement: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6mm dia mild steel wire i/c centring & shuttering , roughening , cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand) etc. complete , excluding the plustering of jambs , sills & soffits as per design , drawing & specification of TSECL. the marker shall be embossed " DANGER: TSECL, ELECTRIC POWER CABLE " with black colour letter (both side) . The visible part shall be painted with yellow colour japan paint.
Erection of anti-climbing devices viz barbed wires on pole structures including supply of barbed wres in helical form 7.5 cm. apart starting from ground level (1.5 Kg. / pole) as per direction of Engineer-in-charge.
GI coil earthing (spiral earthing) i/c supply of necessary materials as per REC specification.
Maintaining adequate clearance from overhead live conductors by trimming of tree branches for way leaves
Asish Debnath
THE TRIPURA ELECTRICAL HOUSE
UTTAM NAG
M/s Bhattacharjee Construction
SUDHANGSHU BHATTACHARJEE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .