Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.2 LAccepted-AOC DOOR NO 58 12 13 KARASA VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | 1 | Accepted-AOC Being Lowest | |
| 2 | 2₹38.5 L+₹92,359 (2.46%)Rejected-Finance | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹40.4 L+₹2.9 L (7.62%)Rejected-Finance DOOR NO 50 01 56 9 FLAT NO 9 SURYA TOWERS ASR NAGAR SEETHAMMADHARA NE VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹41.5 L+₹3.9 L (10.4%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹42.9 L+₹5.3 L (14.2%)Rejected-Finance | 5 | Rejected-Finance Not L-1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Jul 2020, 6:00 pmClosed
GE ND VISAKHAPATNAM
Garrison Engineer Naval Depot Military Engineer Services Industrial Estate PO Visakhapatnam 530 007
PROVISION OF INTERLOCKING PAVER BLOCK AT BUILDING NO P 97 U P 98 V P 100 W PROVISION OF CHAIN LINK FENCING AT NURSERY AND PROPOSED CHILDREN PARK AT SVN COLONY 104 AREA AS AS TO ROOF TREATMENT OF TECHNICAL BUILDING P 10 OTM BUILDING P 1 AND OFFICERS
2020_MES_353235_1
GE(ND)/VIZ/8887 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE ND VISAKHAPATNAM
Class D Category a i
6 documents required · 6 mandatory
₹500
GE ND VISAKHAPATNAM
₹90,000
Yes
18 Sept 2020
16 Jun 2020
20 Jul 2020
16 Jun 2020
14 Jul 2020
30 Jun 2020
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
Dismantling of stone slab and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar
M&L for sand filling under floors or in foundations including watering and consolidation
M&L for machine pressed precast concrete inter locking paver blocks of any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Gde with grey cement and pigment
Demolition of brick and stone wall built in cement mortar including all quoins, arches, pillars built in cement mortar
M&L for brick work with sub class B bricks built in CM 1:6 straight or curved on plan exc. 6 mtrs mean radius.
M&L for rendering in CM 1:4, 15 mm thick on brick surfaces finished fair and even with out using extra cement.
M&L for Preparation of new plastered wall surfaces and applying three coats of white wash complete all as specified.
M&L for PCC 1:3:6 Type C1 (using 20 mm graded coarse aggregate) as in coping etc including necessary form work
Excavation in post holes ( or similar holes ) each n exc 0.50 cum getting out , returning , filling & ramming earth or broken rubble mixed with earth around in layers n. exc 25 cm, watering and removing surplus soil to a distance n exc 50 mtr in hard / dense soil complete all as specified.
M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation , filling & mass concrete complete all as specified
S&F mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165
S&F mild steel Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes, framed guard bars, barred iron doors,ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete al as specified
S&F mild steel TMT round bars 5 mm to 10 mm dia, cut to length, bent to shape required, in spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
S & F mild steel screw bolts ( machine made ) with hexagonal or square heads at one end & screwed the other , or screwed both ends ,each screwed end to be fitted with washer and one hexagonal or square nuts exc. 5cm but n. exc. 10 cm long, 11 to 15mm dia of shank complete all as specified.
Material and labour for two coats of synthetic enamel paint for steel surfaces over one coat of red oxide primer including preparation of surfaces, over 10cm in width or girth, not otherwise described complete all as specified.
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire
Supply only Chain link MS galvanisd fencing, any size or type weight should not less than 2.5kg/sqm complete all as specified and directed
Dismantling of floor hearth or wall tiling including cement mortar bedding and removing rubbish off the premises all as specified and directed
Removal of existing treatment and their roughening surfaces of old concrete floor or concrete surfaces by picking,sweeping clean and washing sown with water to remove dust etc
M&L for Brushing neat cement slurry with 3 kg of cement per square metre
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement
M&L for APP based polymeric water proofing membrane 3 Kg/Sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 0.5 liters/Sq.m followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2Kg/Sq.m each at top and bottom of the membrane complete including sealing all joints by thermo fusion with minimum 10 cm overlap all as per manufacturer's instructions complete all as specified and as directed.
Supply only Integral water proofing compound
Removal of debris to a distance of 5 KM including loading and dumping/ levelling at the destination from ground floor
M&L for cement concrete tiles 300x300x25mm thick machine pressed jointed and pointed in neat cement slurry as in floors and cut and polished with grey and no pigments including screed bed of 15mm thick in CM 1:6
M&L for 100 mm thick PCC 1:3:6 type D2 (using 40 mm graded stone aggregate) for sub base of flooring /hard standing including finishing the surface even and rough to receive the topping layer.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors including 20mm thick screed bed in cement mortar 1:6 complete all as directed.
Taking down cement plaster on brick stone walls, etc, including taking out joints, hacking for key, scrubbing down with water, etc. including removing the debris.
M&L for Preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer
S & F in repairs 15 mm bore chromium plated fancy type long body bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. (Make : Jaquar or its equivalent as approved by GE)
S & F in repairs 15 mm dia superior quality CP angular stop cock with wall flange all as specified. (Make:Jaquar or its equivalent as approved by GE)
S & F in repairs superior quality CP 2 way bib cock with wall flanges all as specified. (Make:Jaquar or its equivalent as approved by GE)
S & F in repairs superior quality CP single lever basin mixer without pop up waste system with 450mm long braided hoses all as specified. (Make:Jaquar or its equivalent as approved by GE)
S & F in repairs superior quality Brass CP mixer for mixing hot & cold water screwed down for iron pipe all as specified. (Make:Jaquar or its equivalent as approved by GE)
S & F in repairs superior quality 150mm dia CP brass towel ring all as specified and directed. (Make:Jaquar or its equivalent as approved by GE)
S & F in repairs superior quality CP brass towel rack with lower hangers 60 cm long (Make:Jaquar or its equivalent as approved by GE)
S & F in repairs Vanity wash hand basin of size 470x305x450 mm complete all as specified and directed. (Make:Cera cat No. B3010101 or its equivalent as approved by GE)
S & F in repairs Vitreous china ware cascade type water closet (white/colour) with suitable seat cover, fixing bolts etc complete all as specified. (Make:Jaquar or its equivalent as approved by GE)
Excavating in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foudation etc or for shafts wells, cesspits manholes pier holes etc n.exc 10Sqm on plan and n.exc 1.50m in depth and getting out in soft /loose soil
Returning filling in , including spreading levelling watering and well ramming in layers not exc 25cm in soft /loose soil
Removing excavated soil material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting oint.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of chemical emulsion per squaremetre of surface area
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion per square metre of vertical surface Note : Area of the sub structure in contact with backfill to be measured
M&L for treating the top surface of filled earth @ 5 ltr/sqm of chemical emulsion per square metre of surface area
M&L for treating the soil under plinth protection @ 5 ltr/sqm chemical emulsion per square metre of surface area
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of chemical emulsion per metre of the perimeter wall
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces
M&L for RCC (M-30 Design mix) (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams bases for columns etc. basement slabs, under-reamed piles and mass concrete etc complete all as specified
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions
M&L for RCC (M-30 Design mix) (using 20mm graded aggregate) as in Columns, pillars, piers, posts and struts etc.,
Use and waste of form work to sides and soffits of floor or roof beams and lintels for fair finished surfaces
M&L for RCC (M-30 Design mix) (using 20mm graded aggregate) as in beams , cantilevers bressumers, lintels over 1.5m span
Use and waste of form work to soffits of suspended slabs such as roof slabs , floor slab, landings and similar work not exc 200mm thick (horizontal or slopping) for fair finished concrete surfaces
M&L for RCC (M-30 Design mix) (using 20mm graded aggregate) as in slabs supported on walls beams and columns in floors roofs landings balconies canopies deck slabs and shelves etc..
Use and waste of form work to chajjas,troughs and chullahoods and similar items including edges for fair finished surfaces.
M&L for RCC (1:1.5:3) tye B1 (using 20mm graded aggregate) as in Chajjas
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally or hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc.
All as per item No 60 above but 5mm dia and over upto and including 10mm dia as in stirrups spacers and binders
M & L for brick work with Fly ash bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6)
M & L for rendering 10 mm thick in CM 1:6 on brick / concrete surfaces and finished even and smooth without using extra cement.
M & L for rendering 5 mm thick in CM 1:4 on concrete surfaces of ceiling finished even and smooth without using extra cement.
M & L for rendering 15mm thick, externally 5 mm in CM (1:4) over 10 mm in CM (1:6) on brick/ concrete surfaces with water proofing compound finished fair and even. Note: WPC will be measured and paid separately.
S&F Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as per specification and drawing
M&L for factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tube for top and botto rails . MS frame shall be covered with heat moulded plain colour PVC "C" channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail either side and as gap insert for top rail & bottom rail Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement supplying and fixing in the frame at site as per specification and drawing.
S&F 200mm long aluminium, anodised barrel tower bolts of extruded section, all as specified and as directed
S&F Aluminium alloy anodised sliding door bolt 300mm long with hasp staple (bolt type) and fixing clips of sheet bast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy as Specified.
S&F 150mm extruded aluminium alloy handle all as specified and as directed
S&F Butt hinges 100mm size extruded aluminium alloy with galvanised mild steel anodised all as Specified and directed.
S&F brass CP angular Stop valve with long shank and cup (concealed type) 15 mm dia bore screwed down with crutch handle both end screwed for iron pipe or union all as specified and directed
S&F brass CP Bib taps 15 mm dia bore type with crutch handle, screwed down, screwed for iron pipe all as specified and directed
S&F PVC connection both end brass union and length 450 mm long for 15 mm bore pipe.
S&F PVC grating 150mm size of PTMT (minimum weight 100gms).
M&L for PVC (SWR) gully trap 125/110mm set and jointing with solvent cement all as specified and directed.
S&F brass CP 20mm dia towel rail of 60cm long fixed with brackets at its ends complete all as specified and directed.
S&F ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed to union etc of size 25mm dia
S&F Vitreous China ware wash hand basin white, flat back, size 550x400 mm with cutting for and pinning ends of brackets or erecting stand including chromium plated 15mm pillar cock, PVC connection, CP waste coupling, 32 mm dia PVC waste pipe all as specified and directed.
S&F Vitreous china ware wash down water closet pan semi-pedestal pattern (Anglo-Indian Type) white, including fixing bolts , flush pipe etc all as specified and directed.
S&F plastic water closet seat (white coloured) closed pattern with flat bottom and cover fixed with mild steel chromium plated or aluminium hinging device or ABS plastic hinging device used all as specified and directed.
S&F Vitreous china ware urinal bowl flat back size of 465X355X265mm white (minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)
S&F CP health faucet including one mtr length SS connecting pipe all as specified as in repairs (Make : Jaquar or its equivalent as approved by GE)
S&F 10 litres capacity low level PVC flushing cistern as in repairs and including 32mm dia PVC flush pipe to connect from flushing cistern to water closet (any pattern) and making good all the Joints all as specified.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in treches or in floors
S&F 75 mm PVC (SWR) floor trap plain with grating including jointing with slovent cement
S&F Rotational moulded Polyethylene water storage tank of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F 3-layer PP-R (Polypropylene random copolymer) pipes 15 mm dia SDR 7.4 & SDR 11 UV stabilised laid & concealed in walls including bends, elbows, unions etc, and laid on walls for vertical stacks including chasing the wall and making good complete all as directed.
All as per item No 90 above but 20 mm dia
S&F Gun-metal, globe or gate valves 20 mm bore, with iron wheel head, screwed both ends for iron pipe fixed in repairs
M& L for Brushing neat cement slurry with 3 kg of cement per sqm and applying 15mm thick in CM (1:4) screed bed on slab with 2% of water proofing compound, Polymer modified bituminous membrane with sand witched polythene film/non woven polyster reinforcement /polymeric water proofing membrane 3Kg/sqm laid over hot blown grade 85/25 @ 1.2kg/Sqm (i.e roof slab cleaned thoroughly to remove all loose particle dust/dirt particle ) shall be laid over entire roof surface and on vertical surface up to grooves ( or as per manufacturers recommendation) with over laps of 100mm, the over lap shall be sealed by flames or as per manufacturer instruction, hot blown bitumen grade 85/25 @1.2kg/Sqm applied over the membrane and one coat of bituminous aluminium primer @ 0.10 Kg/Sqm applied on treated bituminous membrane should be compatible with membrane all as per recommendation of manufacturer and all as specified and directed
M&L for hardcore of gauge exc 63mm but n.exc 100 mm , deposited , spread and levelled in layers n exc. 15 cm thick , watered and rolled/ rammed to a true surface.
M & L for 100 mm thick PCC (1 : 4 :8) type D2 (using 40 mm graded stone aggregate) as in sub base
M&L for 25 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in sub base all as specified.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection laid in alternative panels
M & L for non skid coloured ceramic tiles of 7 to 8 mm thick , area of each tile exceeding 0.11 sq m but not exceeding 0.18Sq m as in floors set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match over a screed bed of 15 mm thick in CM 1:6 complete all as specified and directed.
M & L for Glazed coloured ceramic tiles of size 350X250X7mm / 450X300X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over backing coat of 10mm thick in cement mortar 1:4 for laying skirting, dados and vertical surfaces all as specified and directed
M & L for preparing plastered or unplastered new ceiling surfaces and applying three coats of white wash complete all as directed
M&L for preparing plastered or unplastered new wall surfaces and applying two coats of oil Bound distemper over a coat of cement primer all as specified and directed.
S&F PVC ventilators with frame work made of multi chamber hollow PVC section DWUF 405 (40x46mm) and glass (3mm thick pin headed) is fixed to the frame in the lower section using extruded PVC section having a dimension of 9mm x 14.5mm (GL-19 sintex pvc SECTION) WITH epdm gasket (SPL-003) for both the PVC sections, ventilator's centre mullion shall be made up of multi chamber hollow PVC section DWUF-406 (63.5mmx 40mm) with EPDM gasket is used, GL-19 is fixed to the 3 sides of DWUF-405 and to one side of DWUF 406 (63.5x40mm) above the centre mullion. Glass panels with aluminium lower set is fixed to the frame DWUF-405 on the top of the ventilator for the glass. DWUF 405 and DWUF 406 corners shall be metre cut and welded, jointed with 12mm MS rods (guard bars) and necessary fixtures
M&L for PCC (1:4:8) Type D2 (using 40mm graded stone aggregate) concrete bed to drain pipe 150mm dia bore, including packing under, and haunching against sides of pipes after they are laid and tested in.
M&L for brick work in CM 1:4 using sub class 'B' bricks straight or curved in plan exc. 6 mtrs mean radius.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for coping/benching finished exposed surface of concrete fair and even as specified
M&L for rendering in CM 1:4, 15 mm thick on other than fair faces of brick surfaces finished fair and even with out using extra cement.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitered or stopped ends.
S&F SGSW pipe 15 mm dia laid in trenches and as specified.
M&L for Precast RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) for man hole covers set in CM 1:4.
Removal of surplus soil to a distance exc 250 mtrs and n.exc 500 mtrs, depositing where directed at a level n.exc 1.5 mtrs from starting point.
S&F Galvanised iron pipes medium grade including fittings 25 mm dia complete all as specified and directed
S&F Stop valve of size 25 mm dia screwed down for pipe complete all as specified and directed
Demolition of cement concrete in ground floor and pavings not exc. 15 cm thickness ( below or above ground floor ) complete all as directed
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, as in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 all as specified.
M&L for Non skid coloured ceramic tiles 10 mm thick (square/ rectangular) of size 600 mm x 600 mm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 all as specified and directed
M&L for 25mm thick PCC (1:2:4) type BO (using 12.5mm graded stone aggreagate) as in sub base complete all as specified.
M&L for 75mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggreagate) as in sub base floor from ground floor.
S & F in repairs stainless steel silver finish single soap dish embedded in the wall all as specified and directed
S & F in repairs PVC body cabinet box mirror of size 350mm x 450mm x 100mm in PTMT alloy of approved patterns and design. [Make: PRAYAG, CAT NO-551 or its equivalent as approved by GE]
S & F in repairs Vitreous China Urinal, Half stall type, White (excluding flushing cistern, flush pipe and waste pipe) all as specified and directed
S & F in repairs CP toilet roll paper holder with flap all as specified. (Make : Jaquar or its equivalent as approved by GE)
S & F in repairs Corner glass shelves 225mm radius, 6mm thick as per sample for bath room including suitable support all as directed.
S & F in repairs 15 mm dia chromium plated bib tap of brass type with crutch or butterfly handle from ground floor to 3rd floor
S & F in repairs 15mm dia concealed angle cock complete all as directed.
M&L for false ceiling with 12mm thick gypsum board fixed in GI snap grid single level fixed and applying two coats of plastic emulsion paint over a coat of primer including applying two coats of Altek putty etc including dismantling of old ceiling boards all as specified and directed
M&L for powder coated aluminium frame/shutter for doors, windows, ventilators openable/sliding including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2 Nos), suitable handle (1 No) complete all as speicified and directed including removing of damaged aluminium door/windows/ventilators.
S & F in repairs 5.5 mm thick tinted glass ordinary quality and glazing with rubber gasket in squares exceeding 0.50 sqm in each pane.
S&F in repairs aluminium body door closure hydraulically regulated, designation No.1 universal type, suitable for door shutters up to 700mm in width and of weight not more than 3.5kg
S & F in repairs brass Godrej mortice lock, vertical type, size 100mm 4 levers include for escutcheon plates and two keys
S & F in repairs extruded aluminium alloy handles powder coated 150mm long fabricated type, anodised
S & F in repairs 100mm size butt hinges extruded aluminium alloy with galvanised MS hinges pin, anodised type B-21
S & F in repairs 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminium frame work all as specified and directed
Complete removal of existing treatment on walls and applying two coats of plastic emulsion paint over a coat of primer after finishing wall surface with JK/Birla wall care putty to get a smooth finish all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished even and smooth without using extra cement.
M & L for preparation of newly plastered surfaces of internal wall and applying two coats of internal washable emulsion paint over a coat of alkali resistant primer including Putty upto clear undulence including rubbing with sand paper to obtain a smooth surface upto 3rd floor complete all as specified and directed.
S&F in repairs brass CP shower rose 75mm size fancy type with swivel joint including fixing to steel pipe/union for 15mm dia.
Surface excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil
M&L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in floor including finishing the surface even and smooth all as directed.
M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate)
M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including screed bed 15 mm thick in CM (1:6) rubbing and polishing complete.
M & L for machine cut Kota stone 20 to 25 mm thick in skirtings laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including screed bed 10 mm thick in CM (1:4) rubbing and polishing complete.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing of water proofing compound wherever required. Note: WPC will be measured and paid separately.
S & F mild steel work in roof trusses (Framed), trussed, purlins, crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) conforming to Fe-290 Gde E-165 including distance pieces, cleats , nut & bolt of any size & length etc.
S & F Mild steel flats (40x6mm thick) for hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O
S & F Rolled mild steel framed work as in doors or gates of angle or other section confirming to Fe 290(Gde E - 165), with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete.
S & F welded steel wire fabric netting of weight per Sqm not exc 4 kg complete to steel members as directed.
S & F 1.25 mm thick mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as directed
M & L for 0.50 mm thick prepainted galvalume aluminium zinc coating G.I. based corrugated steel sheet of colour having tensile strength of 550 MPA as in roof covering, fixed with and including self tapping screw complete all as per manufacturer instructions
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with stranded aluminium conductor of size 10 sqmm 2 core.
Taking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc.
M&L for modular point wiring with 1.5sqmm PVC insulated and unsheathed copper cable 1100V grade multistranded drawn in concealed PVC conduit and including provision of PVC insulated, 1.5sqmm copper conductor cable as earth continuity conductor including modular terminal boxes and white cover plate with frame for fixing modular switches, sockets regulator etc for one light /bell/ Fan point controlled by one switch. (Note: Rate includes for cutting chassing in brick masonry surface and making good surface with cement mortar 1:3)
All as per item No 150 above but one socket point 5A is controlled by one independent socket
All as per item No 150 above but with 2.5sqmm PVC insulated unsheathed multistranded copper cable with one run of 2.5sqmm PVC insulated copper cable as earth continuity for power socket on independent board.
S&F Slim design LED recessed round down lighter with 1200 Lumens Superior light output of power consumption 12 Watts and integral driver with all accessories internally pre wired and including connecting up with twin core twisted copper conductor cable with suitable size and make the disturbed surface match with the existing surface complete all as specified and directed
Supply and fix LED Tube light fitting minimum 1800 Lumens output of power consumption 18-20 Watts with aluminium base plate fitting including provision of two number of round / square PVC block and two / three core chord copper conductor cable from ceiling rose to LED light fittings all as specified and directed.
Supply and fix LED Tube light fitting minimum 900 Lumens output of power consumption 8-10 Watts with aluminium base plate fitting including provision of two number of round / square PVC block and two / three core chord copper conductor cable from ceiling rose to LED light fittings all as specified and directed.
Supply and fix LED Mirror light of 500-700 Lumens with all accessories internally prewiried and including connecting up with twin core twisted copper conductor cable with suitable size including taking down existing fittings any type complete all as specified and as directed.
S& F LED Building Security light 4500 Lumens output of power consumption 45 Watts Pressure die cast aluminium housing IP 66 Protection with all accessories internally pre wired and including connecting up with twin core twisted copper conductor cable with suitable size including taking down existing fittings of any type complete all as directed
Supply and fix LED decorative wall lamp LED 7W opal glass with chrome finish
S&F modular switch 1 way one module 6 Amps.
M&L for modular socket out let 3 pin 6 Amps flush type, 230V.
S&F modular socket combination 2 in 1, 3 pin, 6/16 Amps, 230V
S&F in repairs ceiling rose surface bakelite 3 terminals 65X50mm 230V including PVC Box of size 3"X3" round type.
S&F MCB DB vertical TPN 8way ,440 Volts with 200 Amps rated busbar incomming 100A, double door including taking down old unserviceable one Note: MCCB's will be measured and paid separately under relevant item
S&F MCCB TPN 100A Breaking capacity 25 KA complete all as directed.
Supply and fix MCB SP 6-32A, 230 Volt,Curve 'C' Breaking Capacity 10KA
Supply & fix in repairs sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity all as specified and directed
M&L for sub main wiring with 2 runs of 6sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in concealed surface PVC conduits not less than 20mm dia and one run of PVC insulated unsheathed 6 sqmm as earth continuity conductor drawn in PVC conduit with accessories complete NOTE: 3 runs of 6 Sqmm and one run of PVC concealed conduit 20mm dia will be measured as one unit i.e RM
Material and labour for earthing complete with galvanised steel earth plate electrode 600x 600 x 6.0 mm thick buried in ground not less than 2.25 mts deep below ground level with top edge of the plate not less than 1.5 meters below normal ground connected GI earth strip 32x6mm fixed by means of bolts,nuts ,check nuts, and washers of galvanised iron GI pipe 25 mm dia perforated and top edge including necessary excavation earth work etc and earh pit size 300 x 300 x 300 mm with PCC type C1 1:3:6 RCC cover slab with type B1, 1:2:4 as per SSR plate No.3 and testing on completion complete all as directed
M/s Balaji Enterprises
SREE VIJAYALAKSHMI ENTERPRISES
GS ENGINEERS
SRIKRISHNACONSTRUCTIONS
RAGHU RAMA PANDA
Sri Venkateswara Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .