Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance 0 S F ENTERPRISES CHANDAK CHANDAK POONCH POONCH JAMMU KASHMIR 185101 UDYAM JK 14 0008974 | POONCH | JAMMU AND KASHMIR | 185101 | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹8.2 L (6.32%)Admitted-Finance | ₹1.4 Cr+₹8.2 L (6.32%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹9.1 L (7.06%)Admitted-Finance | ₹1.4 Cr+₹9.1 L (7.06%) | L3 | Admitted-Finance |
| 4 | L4₹1.6 Cr+₹30.7 L (23.7%)Admitted-Finance | ₹1.6 Cr+₹30.7 L (23.7%) | L4 | Admitted-Finance |
| 5 | L5₹1.6 Cr+₹31.6 L (24.4%)Admitted-Finance | ₹1.6 Cr+₹31.6 L (24.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S VEENA CONSTRUCTION COMPANY L5 | M/s S. F. ENTERPRISES L1 | M/S HIGHLAND ENGINEERING L3 | M/S ZARDEEP ENTERPRISES L6 | M/S alikeen Electrical Store L4 | M/S ALI MURTAZA L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Creation of Sub-Stations Supply,Installation,Testing & Commissioning of | |||||||||
| 1.01 | 11/0.433kV, 3-phase 250 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for63kVA or higher kVA with LV Cable Box having detachable Aluminiumratings) , and Gland plate | 1 | No | 7,50,000 ₹7,50,000 | 6,50,000 ₹6,50,000 | 7,50,000 ₹7,50,000 | 5,70,000 ₹5,70,000 Lowest | 6,90,000 ₹6,90,000 | 6,50,000 ₹6,50,000 |
| 1.02 | 11/0.433kV, 3-phase 100 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for63kVA or higher kVA with LV Cable Box having detachable Aluminiumratings) , and Gland plate | 1 | No | 3,00,000 ₹3,00,000 | 2,75,000 ₹2,75,000 | 2,50,000 ₹2,50,000 | 2,30,000 ₹2,30,000 Lowest | 3,20,000 ₹3,20,000 | 2,50,000 ₹2,50,000 |
| 1.03 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 2 | Set | 6,500 ₹13,000 | 4,000 ₹8,000 | 8,000 ₹16,000 | 3,000 ₹6,000 Lowest | 4,500 ₹9,000 | 5,000 ₹10,000 |
| 1.04 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type | 12 | Set | 8,500 ₹1,02,000 Lowest | 9,500 ₹1,14,000 | 10,000 ₹1,20,000 | 11,900 ₹1,42,800 | 15,000 ₹1,80,000 | 11,500 ₹1,38,000 |
| 1.05 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 2 | Set | 6,500 ₹13,000 | 3,400 ₹6,800 Lowest | 6,000 ₹12,000 | 3,450 ₹6,900 | 5,000 ₹10,000 | 6,000 ₹12,000 |
| 1.06 | 95 mm² Single Core ,1.1kV Grade, PVC Insulated Stranded ConductorFRLS type | 88 | Mtr | 250 ₹22,000 | 450 ₹39,600 | 200 ₹17,600 Lowest | 250 ₹22,000 | 300 ₹26,400 | 500 ₹44,000 |
| 1.07 | 9 Mtr. Long Pole,ST-410 SP33) | 4 | Nos | 26,500 ₹1,06,000 | 18,500 ₹74,000 | 18,000 ₹72,000 Lowest | 22,500 ₹90,000 | 21,500 ₹86,000 | 18,786 ₹75,144 |
| 1.08 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm | 6 | Nos | 550 ₹3,300 Lowest | 640 ₹3,840 | 700 ₹4,200 | 1,000 ₹6,000 | 1,800 ₹10,800 | 990 ₹5,940 |
| 1.09 | GI Channel/Angle/Flat of sizes including clamps | 1,100 | Kgs | 145 ₹1,59,500 | 130 ₹1,43,000 Lowest | 280 ₹3,08,000 | 160 ₹1,76,000 | 150 ₹1,65,000 | 160 ₹1,76,000 |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
12 May 2025, 12:00 pmClosed
Executive Engineer, Electric Distribution Division
baroo Kargil
Supply, Installation, testing and commissioning for construction of 11 KV Line, Construction of LT line and Creation Sub- Stations for providing Power supply to Various Army Posts at Sandoo top Drass
2025_PDNRE_15995_1
E-NIT NO 07 of 2025-26
Open Tender
Electrical Works
Turn-key
90 days
Drass Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹4,380
Account No 0096010200000064 IFSC Code JAKA0KARGIL
₹4.4 L
Baroo Kargil
15 May 2025
16 Apr 2025
12 May 2025
16 Apr 2025
12 May 2025
26 Apr 2025
16 Apr 2025 - 26 Apr 2025
26 Apr 2025
Amount
Creation of Sub-Stations Supply,Installation,Testing & Commissioning of
11/0.433kV, 3-phase 250 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for63kVA or higher kVA with LV Cable Box having detachable Aluminiumratings) , and Gland plate
11/0.433kV, 3-phase 100 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for63kVA or higher kVA with LV Cable Box having detachable Aluminiumratings) , and Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95 mm² Single Core ,1.1kV Grade, PVC Insulated Stranded ConductorFRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Chemical Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box (1+2) for 250 KVA DTR
LT Distribution Box (1+2) for 100 KVA DTR
Wedge connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like almunium lugs,jumpers,binding tape etc
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp/GI Channel X-arm including clamps and braces.
30 mm² ACSR Conductor
PG Clamps for 30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Providing & fixing of 02mtr long 300 micron GI to GI Chemical Earthing Electrode along with Chemical Gel for Poles through GI Strip 25x3mm.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
8Mtr. Long Pole SP-15
GI Channel with clamps
30Sqmm ACSR Conductor
16KN Polymer pin Insulator
Galvanized Nuts and Bolts
Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3mm.
Red Oxide
Aluminium Paint
Danger plates
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
Supply & laying of 8 SWG GI Wire through eye hooks for earthing of poles
Supply and fixing of Suspension/Tension Clamp with eye hook
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 nos turn-buckle,1.8mtr long,16mm dia solid GS stay rod & 7/3.15mm dia GI stranded wire complete
SITC of 11 KV Tri- Vector Energy Meter oil- immersed along with suitable CT/PT for 100 KVA DTR
SITC of 11 KV Tri- Vector Energy Meter oil- Immersed along with suitable CT/PT for 250 KVA DTR
M/S ALI MURTAZA (BID ID -156089)
M/S HIGHLAND ENGINEERING (BID ID -156096)
M/S alikeen Electrical Store (BID ID -156562)
M/S VEENA CONSTRUCTION COMPANY (BID ID -156082)
M/S ZARDEEP ENTERPRISES (BID ID -156113)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
SBD.pdf
Tender Documents • 1.02 MB
TechSpecTransformers.pdf
Other Document • 0.85 MB
BOQ_39409.xls
BOQ • 0.27 MB
TechSpecPoles.pdf
Additional Documents • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .