CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad New Delhi-110080
IMPROVEMENT WORKS OF PROPLLER OVERHAUL LINE AT AIR FORCE STN CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2022_MES_546005_1
CWE/TKD/CHD/TOKEN-15/2022-23
Open Tender
Electrical and Maintenance Works
Works
500 days
GE (AF) MC Chandigarh
As per NIT conditions
8 documents required · 8 mandatory
₹1,000
GE (AF) MC Chandigarh
₹2.0 L
Yes
17 Nov 2022
18 Aug 2022
10 Sept 2022
18 Aug 2022
8 Sept 2022
25 Aug 2022
Amount
Schedule 'A' Part-I (External Electrification)
Supply, installation,testing and commissioning of indoor type step down transformer of capacity 11000/433 volts (at no load) ,AC , 3 phase 50 Hz capacity 160KVA core type copper wound ,oil immersed ,naturally cooled, oli natural, air natural (ONAN) with external cooling tubes ,delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn-11 (vector group) with neutral brought out on secondary side (LV side) and having tapping +/- 5% with step of 2.5 % side to be changed by means of hand operated off load tap changer gear as per IS 1180:2014. The maximam temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method (Necessary test certificate carried out at factory site to be produced ) after contineous full load run on an ambient temperature of 40 degree celsius .the transformer shall be IS 1180: 2014 Level-2 marked and shall comprise of the following :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing ,copper rods, nut and washers (b)one cable box both side on HT/LT side (primary & secondary side) consisting of 03 Nos & 04 Nos of porcelain insulators respective bushing with copper rods complete with nuts and washers with two nos cable gland suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands joint and jointing material complete (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fills dehydrating agent (silica gel). (e) Explosive vent (f) Thermometer pocket on tank cover (g) One No 100 mm dia , dial type thermometer ,vapour pressure type having range 0-120 degree celsius with metal guard having maximum permissible reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6mm galvanised iron strip for earthing of neutral and body. (j) Including first fill of new and unused transformer oil having dielectric strength 52KV etc complete alll as specified and directed.
Supply, installation , Commissioning and testing of Ring Main unit indoor type One incomming and three Out Going VCB of 12 KV 630 Amps having following standards mechanical data,electrical data,incoming VCB,Outgoing VCB.
Standard and Mechanical data:- (i) Standards and Mechanical Data (ii) Metal Enclosed switchgear : IEC 62271-200 (iii) General purpose switches : IEC 60265-1 (iv) Disconnectors & Earthing switches : IEC 62271-102 (v) Circuit Breaker: IEC 62271-100 (vi) Common clauses: IEC 60694 (vii) Pressure of SF-6 gas: 1.4bar at 20 Deg Cen. (viii) Temperature class: -25to +40 Deg. Cen. indoor (ix) Degree of Protection: (x) SF-6 tank : IP 67 (xi) Front cover : IP 2X (xii) Cable cover : IP 3X (xiii) Busbars : 240Sq mm Copper (xiv) Earth bar (external) ; 120Sq mm Copper - Bolt dimension: M10 (xv) Thickness of stainless stel tank: 2/2.5 mm (xvi) Colours: Front/side and cable cover: RAL 7035
Electrical Data (12 KV - 28 KV - in 1Min) :- (i) Nominal Voltage : 11KV (ii) Rated Frequency : 50HZ (iii) Rated Current busbars : 630A (iv) Rated Current cable switch disconnector :630A (v) Short time withstand current: (vi) Cable switch disconnector with interface C (400 - bolt), bushing : 21KA rms 3 Sec. (vii) Vaccum circuit brakers with interface C (400 - bolt), bushing : 21KA rms 3 Sec. (viii) SF-6 with interference CC (40 - bolt), bushing : 21K Arms 3 Sec. (ix) Rated Current for transformer T off : 630A (x) Impluse withstand voltage : To earth & between phases : 75 KV (xi) Insulation level : Power frequency 1min : 28 KV
Incoming vaccum circuit breaker:- Vaccum circuit breaker module with vaccum circuit breaker three position Isolator / earthing switch, busbar, interlocking and earthbar,and storded spring energy Mechanism (A-mech). (i) Vaccum circuit breaker 12 KV, 630 A. -01 No (ii) Manometer-01 No (iii) Stored energy mech. For manual operation- 01 No (iv) Cable cover standard withinterlocking - 01 No (v) Self powered over current & earth fault protection relay - 01 No (vi) Cable bushing interface C (400 bolted), 630 A - 01 No (vii) Aux switch for vaccum circuit breaker position 2NO+2NC-01No (viii) Capative Voltage indication fixed type VPIS 9-12KV- 01 No (ix) Cable support bar ,standard forn 1 way unit (x)) Ring core current transformer of suitable ratio150-100/1A,2.5A,10 P 10 for protection
Outgoing circuit Breaker : Vaccum circuit breaker module with vaccum circuit breaker ,three position ioslator/earthing,switch ,busbars,interlocking ,earthbar and stored spring energy mechanism (A-mech) (i) VCB 12 KV, 630 A. - 03 No (ii) Stored energy mech for manual operation (iii) Cable cover standard withinterlocking - 01 No (iv) Self powered over current & earth fault protection relay - 01 No (v) Cable bushing interface C (400 bolted), 630 A - 01 No (vi) Aux switch for vaccum circuit breaker position 2NO+2NC-01 (vii) Capative Voltage indication fixed type VPIS 6-12KV- 01 No (viii) Cable support bar ,standerd for 1 way unit.-01 No (ix) Ring core current transformer type 60/1A,2.5VA,10P10 for protection-03No Note : Additional equipment delivered seperately or mounted in respective panel.(a) operating handle
Supply, laying and testing cable XLPE insulated screened PVC bedded,galvanised steel strip or wire armoured electric power cables heavy duty with alminium conductor 11000 volts grade ,cross sectional 185sqmm 3 core.
S&F cable joint kit for 11 KV grade cable for indoor termination cold shrink type joint suitable for 3 core XLPE armoured aluminium cable of size 185 sqmm complete all as specified and directed.
Supply, and Fix MCCB 4 Pole 200 Amps 36 KA with Enclosure fixed on wall all as specified and directed.
Supply install, testing and commisioning of LT panel (CPRI approved) electrical board floor mounted cubical type, indoor type proof aesthetically designed fabricated of 2 mm thick outer CRCA sheet and 2mm thick inner CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber continuous GI strip earth bus bar din rail channels cable alley . danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:- (a) Copper bus bar Four wire system 415 Volts mounted on porcelain heat shrinkable insulator sleeve suitable for 400 amps for phases and 200 Amps for Neutral - Set 1 (b) LED based indicator lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d ) MCCB 250 Amps 36 KA 4 pole with thermal and magnatic release - 1 no for In coming (e ) MCCB 100 Amps 25 KA 4 pole with thermal and magnatic release - 03 Nos as Outgoing (f ) MCCB 63 Amps 25 KA 4pole with thermal and magnatic release - 2No. for Outgoing (g ) MCB 32 Amps 10 KA TPN - 6 Nos for Outgoing
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches under brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 50 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches under bricks and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supply, laying Unarmoured PVC insulated PVC sheathed copper conductor 1100 volts grade of size 10 sqmm 3 core for chiller pumps complete all as specified and as directed.
Excavation in trenches for laying underground cables, poles and stays in of soil not exceeding 1.5m wide and not exceeding 1.5m deep and getting out complete all as specified and as directed.
Returning, filling in, including speading, levelling,watering and well ramming in layers notexceeding 25cms thick complete all as specified and as directed.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supplying and laying reinforced precast concrete cable coverType 3, flat, size 450mm x l80mmx40mm complete all as specified and as directed.
Sand cushioning to under ground cable provided with a layer of 8cm deep before laying the cable and 15cm deep after laying and stretching the cable complete all as specified and as directed.
Brick covering with common burnt clay bricks old size laid as width equal to length of brick for protection to cables with well burnt sub class 'B' bricks laid dry flat all as directed.
Labour for boring upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
Demolation and dismentling of concrete in ground floors and pavings n exc 15 cm thickness(below or above ground level)
M&L for PCC 1 : 2 : 4 type C2 Using 40 mm graded stone aggregate Cement concrete in foundations, filling and mass concrete complete all as specified and directed
S&F Tubes, 'light grade' ISI Marked galvanised tubing 80mm bore with all fitting and fixed complete to laid in floors , road cutting/trenches all as specified and directed.
M&L double wall corrugated (DWC) HDPE pipe outer dia 120mm & inner dia 103mm as per IS 14930 (part-2) 2001 with end cap as in trenches, under road, under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40 x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed.
Material and labour for earthing with Galvanised steel earth plate electrode of size 60cmx 60cm x 6 mm thick buried directlly at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level , earth plate surrounded from all sides by 15cm thick packed layer of charcol dust an common salt filling in alternate layers and electrode connections by using Galvanised iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment ) by means of bolts, nuts, check nuts, and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board of main control board and GI pipe medium grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover 80 mm thick with2 NOs MS bar 16 mm dia handles and PCC chamber pit with PCC (1:3:6) type C-2 using 40 mm graded stone aggregate, including excavation and eath work in any type of soil, returning filling in approved soil and disposal of surplus soil to a distance not excdeering 50m all as specified and shown in electrical plate No. 3 of SSR 2009 ( Part-I) complete all as specified and directed Note:- Resistance of earthing shall be less than 5 Ohms.
Supply install testing and commissioning of 60 Kvar Company make Automatic power factor improvement system of 3-phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and worm in proof, made out of 2 mm M.S Sheet and M.S Angle Iron 40 x 40 x 6mm frame, duly powder coated, front & back open able with locking arrangement to facilitate easy maintenance, heavy Cable entry gland provision, hooks on top for mounting panel in Platform. Complete Capacitor and Reactor Filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel, during the maintenance / replacement. Necessary internal connection with proper copper wire rating & lugs. Proper control wiring with protection to Relay, fans and Thyristor module comprises of following Panel:-
Capacitor Bank:- (i) TP MCB,10KA ,C CURVE,63A-02Nos (ii) Capacitor Duty contactor 230V AC coil with inrush current damping,20Kvar -02Nos (iii) Capacitor Bank ,MDXL Type ,Cyl super heavy duty capacior,440v AC,20 Kvar-02 nos (iv) Illuminated Switch for manual switching & step indication,R-02Nos
Capacitor Bank :- (i) TP MCB-32A,10KA ,C CURVE,63A-01Nos (ii) Capacitor Duty contactor 230V AC coil with inrush current damping,10Kvar -01Nos (iii) Capacitor Bank ,MDXL Type ,Cyl super heavy duty capacior,440v AC,10 Kvar-01 nos (iv) Illuminated Switch for manual switching & step indication,R-01Nos
Capacitor Bank:- (i) TP MCB,10KA ,C CURVE,20A,-01Nos (ii) Capacitor Bank ,MDXL Type ,Cyl super heavy duty capacior,440v AC,5 Kvar-01 nos (iii) Illuminated Switch for manual switching & step indication,R-01Nos
Capacitor Bank:- (i) TP MCB,10KA ,C CURVE,10A-01Nos (ii) Capacitor Duty contactor 230V AC coil with inrush current damping,12A-01Nos (iii) Capacitor Bank ,MDXL Type ,Cyl super heavy duty capacior,440v AC-03 Kvar-01 nos (iv) Illuminated Switch for manual switching & step indication,R-01Nos
Capacitor Bank:- (i) TP MCB,10KA ,C CURVE,6A-01Nos (ii) Capacitor Duty contactor 230V AC coil with inrush current damping,9A -01Nos (iii) Capacitor Bank ,MDXL Type ,Cyl super heavy duty capacior,440v AC-2 Kvar-01 nos (iv) Illuminated Switch for manual switching & step indication,R-01Nos
Schedule 'A' Part-II (Air Conditioing)
Supply ,installation, testing and commissioning of Air cooled Scroll Chiller having capacity not less than 30 TR with eco friendly refrigerant R-410A/R-407C complete with Hermetic sealed Scroll compressor. Package should come with minumun two compressors in each module,complete with microprocessor controller, multiple scroll compressors, shell & tube type water cooled evaporater refrigerant piping, mounted on a common base frame with following specifications:- (a) Chilled water inlet temperature: 54° F, (b) Chilled water outlet temperature: 44 ° F, (c) Evaporater fouling factor: 0.0001 Sq ft Hr ° F/Btu, (d) Ambient conditioins 95 F COP of chiller shall not be less than 3.05. (e) Chiller shall have blue fin coating on Fins. NOTE:- The contractor shall submit Purchase Vouchers for payment of this item.
Supply & installation of monoblock centrifugal pump set with chilled water circulation of 95 USGPM at 30 m head (2 working and 1 standby) including energy efficient motor with 5 star BEE rating ,mechanical seal, baseframe, insulation, foundation bolts etc. all as specified and directed.
Supply, installation, testing and commissioning of factory fabricated Double Skin Chilled Air handling unit cap 20000 CFM horizontal type fabricated out of extruded aluminium section consisting with 0.6 mm pre- plasticized/pre-coated Galvanised steel sheet outside & 0.6 mm plain galvanised steel sheet inside with blower, blower section and Blower shall be DIDW forward Curved/ Airofoil type complete with blower motor TEFC type, 4 Row deep Cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 40 mm thick & 38 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only.The complete AHU shall conform to standard specification.
Supply and installation of Strips heaters arranged in bank of cap 3 Nos x 9 KW each for winter heating / Monsoon reheating complete with necessary controls viz Heating thermostat, gyser stat necessary control wiring etc.
PVC expansion tank cap 500 ltrs insulated with 50mm thick EPS (Expanded Polystyrene) slab covered with Vapour Barrier, Chicken Wire Mesh and Finished with Sand Cement Plaster with overflow valve, float valve as specified.
CHILLED WATER CIRCULATION SYSTEM:- Supply & installation of MS pipes, Heavy Grade, (Class 'C') complete with necessary fittings viz elbow, tees. wooden /PUF saddle (saddle to be laid between pipes and supports). Necessary insulation to chilled water pipe comlete with 50mm thick Nitrile pipe sectionand finally finished with 26 swg Aluminium cladding for following dia of pipe:-
DIA 125 mm
DIA 75 mm
DIA 50 mm
Supply & installation of PN 10 rated or 10 Kg/Sqcm maximum working pressure, butterfly valve complete with necessary flanges, gasket , nutbolts etc all as specified and/or directed for following dia-
DIA 125 mm
DIA 80 mm
Supply & installation of PN 10 rated or 10 Kg/Sqcm maximum working pressure, balancing valve having DIA 80 mm complete with necessary flanges, gasket,nutbolts etc all as specified and directed.
Supply & installation of PN 10 rated or 10 Kg/Sqcm maximum working pressure, dual plate check valve of dia 80 mm complete with necessary flanges, gasket , nut bolts etc complete all as specified and directed.
Supply & installation of 80 mm dia Y strainer complete with necessary flanges, gasket , nutbolts etc complete all as specified and/or directed.
Supply & installation of PN 10 rated or 10 Kg/Sqcm maximum working pressure, three way Mixing / Diverting valve of dia 80 mm complete with necessary flanges, gasket , nutbolts, thermostat and necessary control & Power wiring to motor actuator etc complete all as specified and directed.
Providing and fixing dial type temperature guage/thermometer of range 0-50 ° C at the inlet and outlet of chillers, AHU complete with necessary fittings, all as specified.
Providing and fixing dia dial type pressure guage of range 0-10 Kg/cm2 having dial size 100mm complete with necessary fittings, isolating valves all as specified and directed.
Supply & installation of flow switches for the chilled water line at outlet of cooler all as specified
Supplying & installation of motorized fire damper supply air duct/main branch and where required. The fire damper shall complete actuator motor, fire & smoke panel with control wiring all as specified and directed.
Supply & Installation of GP ducting complete with necessary supports, hanging arrangement, nutbolts, gaskets all as specified and directed for following:-
Supply & Installation of Aluminium powder coated grilles / diffusers for Supply air complete with OBSS complete all as specified and directed.
Supply & Installation of fresh air grill complete with manual GI damper complete all as specified and directed.
Accoustic Lining complete with 9mm open cell nitrile rubber sheet pasted with suitable adhesive and hardware as per design approved by GE complete all as specified and directed.
Ducts insulation with 9mm Nitrile insulation with aluminium foil faced as per design requirement and design approved all as specified and directed.
Civil work considering necesary foundations for Chillers, chilled & condenser water pumps, cooling tower and AHUs. Making openings for Supply & return air ducting and finishing the same all as specified and directed.
Supply & Installation of UPVC pipe of 40 mm dia for condensate drain from AHU to near by drain point with in AHU room all as specified and directed
ELECTRICAL WORK:- Supply and Fixing of PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipments through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specification and drawingsfor following:-
3 core 25 sqmm Aluminium
3 core 16 sqmm Aluminium
3 core 6 sqmm Aluminium
3 core 4 sqmm Aluminium
Providing and Fixing of perforated cable tray 14 SWG duly epoxy painted as per approved shades, complete with supports, Tees Elbows rizers and all necessary hardwares etc for following:-
600 mm x 50 mm
200 mm x 50 mm
Providing and Fixing of control cable of 2 core 1.5 Sqmm shielded and analyed tinned copper for inter locking complete all as speicfied and directed.
Providing and fixing of GI earth continuity conductors between panel boards and equipments as required and as per I.E Rules 1956 complete all as speicfied and directed.
Providing and Fixing aluminium strip of size 25 mm x 3 mm from panel to Chillers, AHUs complete all as specified and directed.
Schedule 'A' Part-III B/R (Misc Works) Note:- All site handed over partly/Phase wise
Excavation in post holes (or similar holes) each n. exc. 0.50 cum and getting out soft/ loose soil, returning filling in and ramming earth in layers n. exc. 25 cm watering and removing surfaces soil and making good disturb surface.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells cesspits manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the demolished material out side the defence land complete all as specified.
Dismantling of kota stone slabs and tiles of any thickness in flooring etc all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints hacking for key scrubbing down with water and removing the demolished material out side the defence land complete all as specified and directed.
Dismantling of existing tarfelt any No of layers/Plaster/Thermo seal etc, as in water proofing treatment to roof and cleaning the surface with wire brushes including removal of all dust or dirt etc to the distance outside the MD land complete all as specified.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Taking down chowkhats or frames exc 1.5 Sqm but not exc. 4 Sqm each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified. NOTE : - This item is to be executed upto the height of 10m from ground floor.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 as in roof slab on wall, beam and column in floors, roofs, landings, balconies, shelves and the like complete all as specified and directed.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for brick work with Sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for use and waste of formwork to sides and soffits of suspended slabs ,floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished surfaces of concrete of flat complete all as specified and directed..
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for machine cut kota stone slab of 18 - 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish as in skirting to vertical surfaces including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for 18 - 20mm thick granite (of any type and shade) work (table rubbed and polished) in floors, steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 incl pointing in white cement(1:2) using marble dust with admixture of pigment to match the shade of granite stone including grinding and polishing, moulding of edges complete over and incl 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and directed.
S & F for mild steel framed work such as grills grating etc with ends of bars shouldred and or riveted or forged into spike, framed guard bars, door, ladder, railings etc and similar work conforming to to Fe 290 Gde-E-165 complete and all as specified.
S&F TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour for providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified.
Forming V-grooves section of size25x20mm by cutting cracks in existing RCC roofs or terracing cleaning out the surface and sealing the same all as per manufacturers instructions complete all as specified.
M&L 10mm thick rendering in CM 1:3 on concrete surfaces on the roof surface finished even and smoth without using extra cement with water proofing compound complete all as specified. Note : (i) Supply only water proofing compound shall be measured and paid separately.
M&L for applying oil bound bituminous primer @ 0.20 Kg/Sqm and providing 3mm thick, APP modified water proofing membrane reinforced with non woven polyester matt weighing not less than 160 gm/Sqm having softening point not less than 150 degree centigrade having tensile strength of 650 N/Sqcm in longitudinal and transverse directions respectively of the reinforcement tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm, end lap, applying a coat of blown grade hot bitumen 90/10 over the membrane @ 1.2 Kg/Sqm and on drying apply a coat of solar reflective bituminous aluminium paint over membrane @ 0.20 Kg/Sqm complete all as specified.
Supply only liquid water proofing compound complete all as specified.
Supply and fix rough cast wired glass, 6 mm thick and glazing with siliconized acrylic sealent/beads (Iron/Cluminium) any type of site requirement in square. Square Exc 0.50 but n exc 0.75 sqm in each pane complete all as specified and directed. Note:- (i) This item to be executed upto height of 20 meter from ground level. (ii) Leakage after fixing of glass pan with siliconized acrylic sealent from frame work completly erected by contractor.
Supply and fixing Sheet glass ordinary quality frosted glass 3mm thick and glazed with oil putty or any types of beads in square n.exc 0.5 Sqm each pane complete all as specified. and directed.
S&F sheet glass ordinary quality glass 4mm thick and glazed with oil putty or any types of beads in square n.exc 0.5 Sqm each pane complete all as specified and directed by Engr-in-Charge.
Material and labour for glass silicon sealent as specified in here-in-above of section 18mm width and 18mm depth for fixing of new and old glass panes all as complete all as specified.
M & L for complete removal of exiting/new suface treatment and provide two coat of oil bound distamper over prepared surface finished with and including 1 mm thick birla white putty over a coat of primer and rubbing with sand paper at any height of building including necessary scaffolding , ladder , formwork etc. complete all as specified and directed by Engr - in- Charge. NOTE : - This item is to be executed upto the height of 6mtr from Ground level.
M&L for preparation to new plastered surfaces of any description exc 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified.
M&L for preparation of old surfaces and applying one coats of oil bound distemper on ceiling complete all as specified and directed. NOTE : - This item is to be executed upto the height of 10 mtr from Ground level.
M&L for preparation to new steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for powder coated aluminium (minimum thickness of polyester powder coating 50 micron) aluminium work for fixed frame portion and shutters frame(any track)/openable windows frame, ventilators frame, partitions with extruded built up standard tubular sections/appropriate Z sections and other sections conforming to IS : 733 and IS : 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/Neoprene gasket roller etc aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle , aluminium snap beading for glazing/gauged/paneling, CP brass/stainless steel screws, complete all as specified and directed.
M&L for Aluminium power coated grill (DECO grill) weight not less than 1.8kg/Sqm fixed to aluminium door /window/ventilator frame including all fixing arrangements including aluminium channels, screws, U or F section etc complete all as specified and directed.
S&F float glass tinted 5mm thick fixed in aluminium frame with aluminium powder coated snap beading including rubber/EPDM gasket, complete all as specified.
M&L for aluminium composite panel sheet of colour and shade as approved by GE of 4mm thickness which consists of 3mm thick termoplastic core of anti-toxic LDPE sandwiches between 2 skins of 0.5mm thick aluminium foils with outer surface finished with 30 PVDF & inner sur;face finished with a thin coat of polyster paint, cladding panel fixed to aluminium grid of size n.exc 2 sqm and size of section shall be 38mm x 50mm x 1.5mm thick, aluminium grid fixed to wall by FI clamp 25 x 6mm lwith spacing not more than 1m c/c, solour shade and pattern as approved by GE including all necessary frame work & complete as directed by Engr-in-Charge. Make : Euroboard/Armstrong/Alstom Internaltional Private Limited.
S&F 100mm size aluminium anodized powder coated butt hinges ISI Marked complete all as specified and directed.
S&F mild steel mortice lock vertical type 100mm size, 4 lever fixed in aluminium shutter complete all as specified and directed.
S&F 200mm long powder coated aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 200mm size powder coated (any tint) aluminium "American Handle" fixed to aluminium door with suitable screws complete all as specified and directed.
S&F door closer hydraulically regulated aluminium (Die cast body), designation No 3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm
Removing excavated material n.exc1. 50km and depositing where directed at a level n.exc 5Km above the staring point in soil
M & L 12mm thick glass reinforced gypsum ( GRP ) ceiling tiles of size 595 X 595mm of approved design fixed with powder coated ( powder coating on web bottom only ) GI grid consisting of main tee section of size ( 15mm X 30mm ) cross section of size (15 X 23mm ) and powder coated GI wall angle of size ( 20 X 20mm) suitable for mounting tiles of (595 X 595mm ) with 4mm dia GI wire suspender including fabrication complete all as per manufacture instruction fixed with steel rawl plug with nut and bolts arrangement with grid size ( 60 X 120cm )complete all as specified and directed.
M&L for 6mm thick Epoxy PU flooring complete all as specified and directed and as per manufacturer's instruction consisting of following steps/Stages. (i) SURFACE CLEANING: cleaning of surface free from dust, dirt, moisture & foreign material from the floor by grinding and scrubbing. (ii) M & L for Epoxy polyurethane floor coating consisting of 200 micron thick priming coat, 3800 microns screed coat and 2000 micron thick top coa including necessary preparation of the existing surface all as per the maufacturer's instructions complete all as specified and as directed . (iii) forming joints 8mm to 40mm average width and 20mm average deep with closed cell poyethylene backup rod of required dia more than width of joint and top 12mm depth primed and sealed with polyurethane based sealing compound including applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape by mechanical means after application of sealant including cutting out the exiting joints up to the required width /depth using diamond cutter , removing the debris and other foreign materials to a distance exceedig 1.5KM and not exceeding 5.0KM and deposting where directed and cleaninf the sides and bottom of joints by using compressed air complete all as specifiedand as directed . NOTE :- (THE entire work/ application shall be done through manufacturer)
M & L for aromatic PU coating over primer , with PU marking paint approved as per manufacture's instructions/spections as in line, dashes, arrows, letters, width or girth exceeding 10cm, marking in yellow/white/red/orange colour as approved by GE complete all as specified and as directed. NOTE :-(THE entire work/ application shall be done through manufacturer)
M&L for PCC1:2:4 type B- 0 using 12.5 graded aggregate 40mm thick as in Sub base of floor complete all as specified and directed.
M&L for powder coated aluminium (minimum thickness of polyester powder coating 50 micron) aluminium work for shutter of door , sliding door (any track)/openable windows,sliding window, ventilators, partitions and sliding/openable with extruded built up standard tubular sections/appropriate Z sections and other sections conforming to IS : 733 and IS : 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/Neoprene gasket roller etc aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle , aluminium snap beading for glazing/gauged/paneling, CP brass/stainless steel screws, complete all as specified and directed.
M&L for PCC1:2:4 type B-0 using 12.5mm graded aggregate 25mm thick as in pavement complete all as specified and directed.
Schedule of Credit
M/s Luxmi Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .