Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC SADAR BAZAR PRINZE ROAD SAHANTOSHREE PALLY PHASE II P O P S BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.6 L+₹1.1 L (4.11%)Rejected-AOC | L2 | Rejected-AOC High Rate | |
| 3 | L3₹29.3 L+₹1.8 L (6.68%)Rejected-AOC 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L3 | Rejected-AOC High Rate | |
| 4 | L4₹30.3 L+₹2.8 L (10.1%)Rejected-AOC 296 N 183 2 JOGEN GANGULY STREET MONIRAMPUR BARRACKPORE DIST 24 PARGANAS N KOLKATA 700 120 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-AOC High Rate | |
| 5 | L5₹30.3 L+₹2.9 L (10.4%)Rejected-AOC | L5 | Rejected-AOC High Rate |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
18 Nov 2021, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
MANNING AND OPERATION AND MISC REPAIRS TO CENTRAL AC PLANT AT 6 WING AF UNDER GE (AF) BARRACKPORE
2021_MES_483303_1
8332/BKP/AF OF 2021-22
Open Tender
Civil Works
Item Rate
335 days
6 WING AF BARRACKPORE
Pl refer tender documents
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹52,000
Yes
24 Dec 2021
22 Oct 2021
20 Nov 2021
22 Oct 2021
18 Nov 2021
6 Nov 2021
Amount
Manning & Operation of Central AC plants at Bison Lab, at 6 Wing Air Force Barrackpore for 2 Shifts per day i.e 08 hours per shift comprissing with the following personal including Sunday and holidays for operation of AC Plants and record the details of plant running hrs all as directed by Engineer-in-Charge. One Ref Mech Skilled per shift for 02 shift per day List of equipments :- (a) AC plant with control panel, chiller pump & condensor pump of capacity 190 TR - 02 nos (b) AHU with control Panel-04 No (c) APFC Panel-02 Nos (d) DG set 200 KVA with control panel-01 No (f) DG set 320 KVA with control panel-01 No
All as per item No 1 above but one Helper Semi- Skilled per shift for 02 shift per day Note for item Nos 1 & 2:- The rate is deemed inclusive of following:- (i) Quoted rates inclusive maintenance/replacement of fan belts and electrolyte/distilled water up to serviceable condition to equipments as and when required (ii) Maintaining control valves leak proof by replacing/maintaining/ up keeping of gland packing etc in pump house installations’ (iii) Routine check up of oil/fuel levels & minor leakages of DG set, PB’s complete all as specified and directed (iv) Attending fuse-Off calls and minor break downs as directed by Engineer-in-Charge. (v) Cutting bushes,, cleaning installation maintaining hygiene thoroughly by cleaning inside and outside of installation all as specified and directed (vi) All Uniform will be issued/provided by the contractor. (vii) Insulation tape, fuse wire, hand gloves, torch with cell, cleaning material etc will be provided by contractor. (viii) Refrigerator tool kit complete to be provided in installation for day to day requirement. Make- Taparia/Venus/Creative as approved by Engr-In-Charge.
Manning , operation, maintenance / complaint of the day to day service attending reularly including sunday and holiday at 6 Wing Air Force Barrackpore One Refrigerater Mechanic per Shift for 1 shifts per day ie 8 hours . (a) one refrigeration mechanic (Skilled) -one shift in each day including sunday and holiday.
All as per item No 3 above but one Helper Semi- Skilled per shift for 02 shift per day
M&L taking down of chiller/condensing Motor (15 HP) from foundation after disconnecting all electric connection. Re-fixing the same after making proper alignment, replacement metal coupling alongwith rubber bush complete including nuts/bolts/washers, gland packing (for pump), rusted nuts bolts, insulation, bearing of motor (as per existing size),winding.varnishing, heating and complete greasing etc. Testing the same on load all as directed.
M&L for dismentling of Starter motor, complete checking the wiring and re-connect the same after repair and testing the same after replacement of the following defective spares :- (a) Replacement of contactor of capacity 32 Amp, 3 Pole, 415 Volt, AC rating 1, Type MNX 32. (Make : L&T/C&S) - 02 Nos (b) Replacement of add on auxiliary contact block (2 NO + 2 NC) -02 (Make : L&T/C&S)
M&L for fixing in repair pressure guage (0-16 Kg/Cm2) complete all as directed.
M&L for taking down butterfly valve of 100mm dia, replacement rubber gaskate, descaling the gate and refixing the same all as directed.
Oenix and associates
SUDHA ENTERPRISES
M/S A. J. CONSTRUCTION
M/S. B. N. CHATTERJEE
BUSINESS SYNDICATE
ROY CONSTRUCTION
APOLLO TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .