Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder and quoted reasonable rate | |
| 2 | L2₹30.4 L+₹9,165.50 (0.30%)Rejected-Finance SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹33.4 L+₹3.1 L (10.1%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.9 L+₹5.6 L (18.4%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹36.8 L+₹6.5 L (21.5%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹34.4 L
EMD Value
₹68,720
Closing Date
18 Dec 2023, 6:00 pmClosed
Garrison Engineer, Kargil
Garrison Engineer, Kargil PIN - 908121 C/o 56 APO
SPL REPAIR TO WATER SUPPLY SYSTEM OF VARIOUS UNITS AT KARGIL, UNDER GROUND CABLE, LT PANEL AND CONNECTED ITEMS OF 250 FD WKSP COY AT DRAS, PROVN OF REFRIGERATION EQPT AT 56 MTN BDE CAMP AND PROVN OF 09 x WALL MOUNTED FAN AT 121 (I) INF BDE GP CAMP
2023_MES_622014_2
GE/K-48/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kargil
₹68,720
20 Jan 2024
25 Nov 2023
20 Dec 2023
25 Nov 2023
18 Dec 2023
4 Dec 2023
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in hard/ dense soil complete all as specified.
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 Cm thick, all as directed.
Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, all as directed.
Taking up or down old unserviceable GI/MS tubing and connetions including all fittings from the trenches , wall , floor etc complete as directed.
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
100 mm bore size
150 mm bore size
Relaying/refixing after repairing/Cleaning thoroughly by using steel rod/splitted bamboos complete to the GI/MS pipes in old or new position obtained from above item No. 4 including all fittings complete of following sizes in trenches :-
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
100 mm bore size
150 mm bore size
Material and labour for laying of GI tubing medium grade ISI marked complete with all necessary fittings of the follwing sizes in trenches .
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
100 mm bore size
Supply ,laying jointing,commissioning and testing Ductile iron pipe of bore size 150 mm with spigot and socket end centrifugally cast(spun), including rubber gaskit Joint (Tyton Joint), class K-9 conforming to IS-8329-2000 in any length laid in trenches complete all as specified and directed.
S&F cast iron sluice valve, class PN 1.6, conforming to IS-14846, ISI marked with brass spindle complete with flanged ends including necessary nuts, bolts, washers and rubber gaskets, 3mm thick, heavy duty and iron wheel complete with jointing material including taking out old unserviceable sluice valve of following sizes :-
Supply and fix valve, reflex/NRV with by pass Arrangement 150 mm dia,including taking out of old unserviceable valve.
Supply and fix valve, reflex/NRV with by pass Arrangement 80 mm dia including taking out of old unserviceable valve.
Supply and fixed cast iron air release valves with two air outlets,80 mm dia bore and fixing up in cast iron water supply mains including taking out of old unserviceable valve.
S&F Gun metal gate valve 20 mm bore with iron hand wheel head, screwed both ends for iron pipes and fixed complete including taking down of old one .
All as per above item No. 12.00, but of sizes 25 mm bore .
All as per above item No. 12.00 but of sizes 40 mm bore .
All as per above item No.12.00 but of sizes 50 mm bore.
S&F rotational moulded polyethylene water storage tanks of capacity of 500 (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F rotational moulded polyethylene water storage tanks of capacity of 1000 (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
Supplying & fixing DI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia .
Supply and fixing Run lead joint for 150mm dia pipe all as specified and directed.
Supply and fixing Run lead joint for 100mm dia pipe all as specified and directed.
Material and labour for PCC(1:2:4)type B1 using 20 mm graded crushed stone aggregate as in coping, etc, including necessary form work complete,including cutting of roads all as directed.
Material and labour for PCC(1:4:8)type D2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete including necessary form work ,including cutting of roads complete all as directed.
Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed of size 25 mm. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms)
Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixedof size 20 mm. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms)
M & L for river sand, spread dry in trenches as in cable cushioning ,Before laying the cable, the trench shall be provided with a layer of sand of 8 cm depth and the cable has been properly straightened, it shall be covered with sand to a depth of 15 cm , then gently punned down to a depth of 10 cm above the top of the upper-most cable and punning shall be done by hand all as specified and as directed.
M&L for Factory made un-reinforced precast cement concrete cable cover class LV, flat of size 250mmx150mmx40mm, laid dry over electric cable for protection all as specified.
Taking up or down unserviceable steel tubing and connections for removal to store 40/50 mm or credited to contractor complete.
Supply and Fixing GI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. all as specified and as directed.
M& L for boring of holes under road pavment/hard standing by manual boring including making good to the distrubed surfaces complete all as specified and directed
Taking down old unserviceable UG cable of any size.
M & L for LT UG cable 2 core x 16 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing complete all as specified and as directed. Notes: (a) Excavation earth work and sand cushioning brick protectionand connected work etc. Shall be measured and paid separately under relevant item of schedule
All as per Item No 30.00 but for 3.5 core x 50 Sqmm
All as per Item No 30.00 but for 3.5 core x 70 Sqmm
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading and brass cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation , panel shall be mounted on angle of size (40 x 40 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs of suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) or as manufacturer instruction and including notice board & Danger plate complete with all connections incoming / out going complete all as directed by Engineer-in-charg and comprising of following accessories (i) Bus bar chamber consisting of four Nos Aluminium bus bar of capacity 315 Amp duly sleeved ,duly insulated with PVC sleeves RYBN , mounted on heavy duty epoxy insulation in separate compartment. (ii)Ammeter 0-315 Amps, size 4"x4" digital along with suitable size of CT's-01 Nos (iii)Volt meter 0-500 volts size 4"x4" digital - 01 No (iv) LED type indicating lamps (RYB) with holders controlled by fuses and swicthes. (v) Panel board internal wiring with suitable rated PVC insulated copper conductors. (vi) MCCB 3ø phase 415V, 200 Amps 4 pole 36 kA, Adjustable magnetic and fixed thermal - 1 No (I/C) (vii) MCCB 3ø phase 415V, 125 Amps 4 pole 16 kA, Fixed magnetic and Fixed thermal - 1 No (O/G) (viii) MCCB 3ø phase 415V, 63 Amps 4 pole 16 kA, Fixed magnetic and Fixed thermal - 3 No (O/G) Note: Contractor shall provide drawing of LT panel for approval of GE before placing order to manufacturer.
M & L for earthing complete with Galvanized Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to and including GI iron strip of size 32x6 mm flat by means of GI bolts, nuts, and washers, protected by 40mm bore GI light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggrgate) including TMT reinforcement 80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-I and all as directed. Note : (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing strip upto test point from top of the earth plate and further upto body of electrical equipment shall be including in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engr-in-charge. No extra payment shall be made on this account.
Supply, installation, testing and commissioning of Deep Freezer Hard top 320 Ltr capacity having double door, single phase 240 volt, 50 Hz, all as specified and directed.
Supply, installation, testing and commissioning of refrigerators, electric driven single phase capacity 195 Ltrs, 5 Star rated inverted type, double door type, all as specified and directed.
Supply and fixing of voltage stablizer for automatic operation single phase naturally air cooled indoor operation and design for input variation 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of + 2.5% and of capacity 1 KVA, all as specified and directed.
S&F wall mounted fan,plastic body, AC single phase,230 V of size 400 mm sweep with blades to be fixed with wall with necessary fixing arrangement, requred to make good surfacee.Make:Havells Platina, complete all as specified & directed.
M&L for point wiring for light/fan/bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc as specified and directed by Enginneer-in-charge.
As per all item No. 39.00 above but for multi 5 pin 5 amps flush type socket outlet on independent board.
S&F ceiling rose on PVC square blocks surface bakelite 3 terminal. (Make Havells, Anchor, Standard)
Note : Deduction for amount of Rs 151400.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
M/S SUN RISE BUILDERS
M/S TRADE LINK
KASHMIR FAIR DEAL SERVICES
M/s Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .