Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
11 Sept 2026, 6:00 pmClosed
Garrison Engineer (Air Force) Bidar
Garrison Engineer (Air Force) Bidar, Military Engineer Services, Air Force Station Bidar, Bidar-585401
REPAIRS AND MAINT TO SUBMERSIBLE AND CENTRIFUGAL PUMP SET OF VARIOUS CAPACITY AND CONNECTED WORK UNDER GE (AF) BIDAR
2026_MES_784448_1
CA NO. GE(AF)/BID/TOKEN/34 OF 2026-2027 8259/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹36,000
Yes
18 Sept 2026
14 Aug 2026
18 Sept 2026
14 Aug 2026
11 Sept 2026
28 Aug 2026
14 Aug 2026 - 27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | SCHEDULE OF WORKS | - | - | - | - |
| 1 | Disconnecting and removing unserviceable MCCB, 4 pole, 350 Amps and S&F MCCB, 4 pole, 350 Amps, 50 Hz, 415 volts, rupturing capacity 36 KA including connecting the cables complete all as specified and as directed. | 1 | EACH | - | - |
| 2 | Disconnecting and removing unserviceable MCCB, 4 pole, 200 Amps and S&F MCCB, 4 pole, 200 Amps, 50 Hz, 415 volts, rupturing capacity 50 KA including connecting the cables complete all as specified and as directed. | 1 | EACH | - | - |
| 3 | Disconnecting and removing unserviceable MCCB, 4 pole, 160 Amps and S&F MCCB, 4 pole, 160 Amps, 50 Hz, 415 volts, rupturing capacity 36 KA including connecting the cables complete all as specified and as directed. | 2 | EACH | 100 | ₹200 |
| 4 | Disconnecting and removing unserviceable MCCB, 3 pole, 160 Amps and S&F MCCB, 3 pole, 160 Amps, 50 Hz, 415 volts, rupturing capacity 36 KA including connecting the cables complete all as specified and as directed. | 2 | EACH | 53 | ₹106 |
| 5 | Disconnecting and removing unserviceable Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 13 to 21 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 32 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. | 2 | EACH | 10 | ₹20 |
| 6 | Disconnecting and removing unserviceable Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 20 to 32 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. | 1 | EACH | 11 | ₹11 |
| 7 | Disconnecting and removing unserviceable Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 28 to 42 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 42 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. | 1 | EACH | 12 | ₹12 |
| 8 | Disconnecting and removing unserviceable DOL starter and S & F DOL starter Type - MK1, 15A, 3 Phase, 50 Cycles, Relay Range up to 9-14A, 415V/440V including connecting the cable complete all as specified and as directed. | 5 | EACH | 13 | ₹65 |
| 9 | Disconnecting and removing unserviceable 3Pole Contactor and S & F 3 Pole Contactor 32 Amps, Coil Voltage : 415V, 50 Hz including connecting the cable complete all as specified and as directed. | 5 | EACH | 14 | ₹70 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8259.pdf
Tender Documents • 0.98 MB
BOQ_878972.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .