| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.0 LAccepted-Finance | 1 | Accepted-Finance L1 Contractor | |
| 2 | 2₹6.2 L+₹21,289 (3.57%)Rejected-Finance | 2 | Rejected-Finance Not L1 Contractor | |
| 3 | 3₹6.9 L+₹92,269 (15.5%)Rejected-Finance | 3 | Rejected-Finance Not L1 Contractor | |
| 4 | 4₹7.4 L+₹1.4 L (23.4%)Rejected-Finance | 4 | Rejected-Finance Not L1 Contractor | |
| 5 | Rejected-Technical | - | Rejected-Technical Experience Certificate not as per tender notice clause no. 1.29 |
Tender Value
₹7.4 L
EMD Value
₹15,300
Closing Date
20 Dec 2023, 6:00 pmClosed
Director
NIT, Calicut, Kerala - 673601
Renovation of light points at Machines lab, EED
2023_NITC_782122_1
Engg/EMU/AE/210/MC Lab-Lighting/2023-24
Open Tender
Electrical Works
Item Rate
60 days
NIT, Calicut
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹15,300
Yes
18 Jan 2024
22 Nov 2023
22 Dec 2023
22 Nov 2023
20 Dec 2023
22 Nov 2023
Amount
Wiring for light / Fan points with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class ivory coloured PVC conduit with modular switch, modular plate, suitable G. I box earthing the point with 1.5 sq mm green coloured FRLS PVC insulatd copper conductor single core cable etc, as required. (Group C)
Supplying and fixing of 20 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing of 3 x 1.5 sq. mm FRLS PVC insulated copper conductor, Flexible cable in the existing surface/ recessed PVC conduit as required
Supplying and fixing 5 to 32 A rating, 240 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 to 32 A rating, 240 V, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, double pole, 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 12way Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) as required .
Supplying and fixing 16way Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) as required .
Supplying and fixing 5/6 A Switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply and fixing of 10/12W 2 ft LED tube with extruded aluminium batten, suitable for surface mounting with all accessories etc, as required. (Phillips BN 021 LED 12S 6500 PSU GR or compatible)
Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders, suitable size GI angle brackets for support and 18/20 watt 4 feet T8 LED tube etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 118 I, or compatible)
Supply and fixing of box type tube fittings (Twin tube type) (Batten & T8 LED Tube), complete with side holders, suitable size check nuts for fixing on rod and 18/20 watt 4 feet T8 LED tube (2 Nos) etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 118 I, or compatible)
Supply and fixing 380 mm sweep 1400 rpm Medium duty exhaust fan working on 240 Volts AC supply, on existing ventilator, including minor industrial work, cutting grills and fixing extra suitable size painted metal angle welded for supports if required, covering remaining area with wooden sheet, making good the damages, giving connections using 1.5 sq.mm 3 core round flexible copper wire, etc as required.
Supply of 28W 1200 mm sweep 5 Star rated BLDC ceiling fan with input voltage range (140-285V), 380 rpm, Air delivery 235 m3/min, regulator supported type, Aluminium Blade material ,white colour,with 3 years onsite warranty, conforming to IS:374:2019 latest (Atomberg Efficio)*** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Installation Testing and Commissioning of ceiling fan including Supply and fixing of 8/10mm "S/U" type steel fan hook, wiring the down rods of standard length (up to 30 cm) with .5 sq.mm FRLS PVC insulated copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15mm dia, heavy gauge including giving connection with 0.5 sq.mm 3 core round flexible copper wire and painting the down rod etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Charges for removing the existing Light/ Fan points including wiring & pipe, making good the damages of the wall / floor, painting other accessories and conveyance of the material to the godown without any damage etc. as required.
Charges for removing the old Distribution board with MCB, RCCB, & other accessories without any damage and making good the damages of the wall including painting, etc. as required.
Sivaprathapan KB
MAHESH KR
JAITECH ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .